Operational flexibility options in power plants with integrated post-combustion capture.

Saved in:
Bibliographic Details
Title: Operational flexibility options in power plants with integrated post-combustion capture.
Authors: Sanchez Fernandez, E.1 eva.sanchez@ed.ac.uk, Sanchez del Rio, M.1, Chalmers, H.1, Khakharia, P.2, Goetheer, E.L.V.2, Gibbins, J.1, Lucquiaud, M.1
Source: International Journal of Greenhouse Gas Control. May2016 Part 2, Vol. 48, p275-289. 15p.
Subject Terms: *Carbon sequestration, *Fossil fuel power plants, *Electricity, Centrifugal compressors, Revenue management
Abstract: Flexibility in power plants with amine based carbon dioxide (CO 2 ) capture is widely recognised as a way of improving power plant revenues. Despite the prior art, its value as a way to improve power plant revenues is still unclear. Most studies are based on simplifying assumptions about the capabilities of power plants to operate at part load and to regenerate additional solvent after interim storage of solvent. This work addresses this gap by examining the operational flexibility of supercritical coal power plants with amine based CO 2 capture, using a rigorous fully integrated model. The part-load performance with capture and with additional solvent regeneration, of two coal-fired supercritical power plant configurations designed for base load operation with capture, and with the ability to fully bypass capture, is reported. With advanced integration options configuration, including boiler sliding pressure control, uncontrolled steam extraction with a floating crossover pressure, constant stripper pressure operation and compressor inlet guide vanes, a significant reduction of the electricity output penalty at part load is observed. For instance at 50% fuel input and 90% capture, the electricity output penalty reduces from 458 kWh/tCO 2 (with conventional integration options) to 345 kWh/tCO 2 (with advanced integration options), compared to a reduction from 361 kWh/tCO 2 to 342 kWh/tCO 2 at 100% fuel input and 90% capture. However, advanced integration options allow for additional solvent regeneration to a lower magnitude than conventional integration options. The latter can maintain CO 2 flow export within 10% of maximum flow across 30–78% of MCR (maximum continuous rating). For this configuration, one hour of interim solvent storage at 100% MCR is evaluated to be optimally regenerated in 4 h at 55% MCR, and 3 h at 30% MCR, providing rigorously validated useful guidelines for the increasing number of techno-economic studies on power plant flexibility, and CO 2 flow profiles for further studies on integrated CO 2 networks. [ABSTRACT FROM AUTHOR]
Copyright of International Journal of Greenhouse Gas Control is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: GreenFILE
FullText Text:
  Availability: 0
Header DbId: 8gh
DbLabel: GreenFILE
An: 115022683
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Operational flexibility options in power plants with integrated post-combustion capture.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Sanchez+Fernandez%2C+E%2E%22">Sanchez Fernandez, E.</searchLink><relatesTo>1</relatesTo><i> eva.sanchez@ed.ac.uk</i><br /><searchLink fieldCode="AR" term="%22Sanchez+del+Rio%2C+M%2E%22">Sanchez del Rio, M.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Chalmers%2C+H%2E%22">Chalmers, H.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Khakharia%2C+P%2E%22">Khakharia, P.</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Goetheer%2C+E%2EL%2EV%2E%22">Goetheer, E.L.V.</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Gibbins%2C+J%2E%22">Gibbins, J.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Lucquiaud%2C+M%2E%22">Lucquiaud, M.</searchLink><relatesTo>1</relatesTo>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22International+Journal+of+Greenhouse+Gas+Control%22">International Journal of Greenhouse Gas Control</searchLink>. May2016 Part 2, Vol. 48, p275-289. 15p.
– Name: Subject
  Label: Subject Terms
  Group: Su
  Data: *<searchLink fieldCode="DE" term="%22Carbon+sequestration%22">Carbon sequestration</searchLink><br />*<searchLink fieldCode="DE" term="%22Fossil+fuel+power+plants%22">Fossil fuel power plants</searchLink><br />*<searchLink fieldCode="DE" term="%22Electricity%22">Electricity</searchLink><br /><searchLink fieldCode="DE" term="%22Centrifugal+compressors%22">Centrifugal compressors</searchLink><br /><searchLink fieldCode="DE" term="%22Revenue+management%22">Revenue management</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Flexibility in power plants with amine based carbon dioxide (CO 2 ) capture is widely recognised as a way of improving power plant revenues. Despite the prior art, its value as a way to improve power plant revenues is still unclear. Most studies are based on simplifying assumptions about the capabilities of power plants to operate at part load and to regenerate additional solvent after interim storage of solvent. This work addresses this gap by examining the operational flexibility of supercritical coal power plants with amine based CO 2 capture, using a rigorous fully integrated model. The part-load performance with capture and with additional solvent regeneration, of two coal-fired supercritical power plant configurations designed for base load operation with capture, and with the ability to fully bypass capture, is reported. With advanced integration options configuration, including boiler sliding pressure control, uncontrolled steam extraction with a floating crossover pressure, constant stripper pressure operation and compressor inlet guide vanes, a significant reduction of the electricity output penalty at part load is observed. For instance at 50% fuel input and 90% capture, the electricity output penalty reduces from 458 kWh/tCO 2 (with conventional integration options) to 345 kWh/tCO 2 (with advanced integration options), compared to a reduction from 361 kWh/tCO 2 to 342 kWh/tCO 2 at 100% fuel input and 90% capture. However, advanced integration options allow for additional solvent regeneration to a lower magnitude than conventional integration options. The latter can maintain CO 2 flow export within 10% of maximum flow across 30–78% of MCR (maximum continuous rating). For this configuration, one hour of interim solvent storage at 100% MCR is evaluated to be optimally regenerated in 4 h at 55% MCR, and 3 h at 30% MCR, providing rigorously validated useful guidelines for the increasing number of techno-economic studies on power plant flexibility, and CO 2 flow profiles for further studies on integrated CO 2 networks. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of International Journal of Greenhouse Gas Control is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=8gh&AN=115022683
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1016/j.ijggc.2016.01.027
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 15
        StartPage: 275
    Subjects:
      – SubjectFull: Carbon sequestration
        Type: general
      – SubjectFull: Fossil fuel power plants
        Type: general
      – SubjectFull: Electricity
        Type: general
      – SubjectFull: Centrifugal compressors
        Type: general
      – SubjectFull: Revenue management
        Type: general
    Titles:
      – TitleFull: Operational flexibility options in power plants with integrated post-combustion capture.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Sanchez Fernandez, E.
      – PersonEntity:
          Name:
            NameFull: Sanchez del Rio, M.
      – PersonEntity:
          Name:
            NameFull: Chalmers, H.
      – PersonEntity:
          Name:
            NameFull: Khakharia, P.
      – PersonEntity:
          Name:
            NameFull: Goetheer, E.L.V.
      – PersonEntity:
          Name:
            NameFull: Gibbins, J.
      – PersonEntity:
          Name:
            NameFull: Lucquiaud, M.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 02
              M: 05
              Text: May2016 Part 2
              Type: published
              Y: 2016
          Identifiers:
            – Type: issn-print
              Value: 17505836
          Numbering:
            – Type: volume
              Value: 48
          Titles:
            – TitleFull: International Journal of Greenhouse Gas Control
              Type: main
ResultId 1