Dosimetric impact of rotational errors on the quality of VMAT‐SRS for multiple brain metastases: Comparison between single‐ and two‐isocenter treatment planning techniques.

Saved in:
Bibliographic Details
Title: Dosimetric impact of rotational errors on the quality of VMAT‐SRS for multiple brain metastases: Comparison between single‐ and two‐isocenter treatment planning techniques.
Authors: Prentou, Georgia1, Pappas, Eleftherios P1, Logothetis, Andreas1, Koutsouveli, Efi2, Pantelis, Evaggelos1, Papagiannis, Panagiotis1, Karaiskos, Pantelis1, pkaraisk@med.uoa.gr
Source: Journal of Applied Clinical Medical Physics; Mar2020, Vol. 21 Issue 3, p32-44, 13p
Database: Applied Science & Technology Source
FullText Text:
  Availability: 0
Header DbId: aci
DbLabel: Applied Science & Technology Source
An: 142266710
AccessLevel: 2
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Dosimetric impact of rotational errors on the quality of VMAT‐SRS for multiple brain metastases: Comparison between single‐ and two‐isocenter treatment planning techniques.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AU" term="%22Prentou%2C+Georgia%22">Prentou, Georgia</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AU" term="%22Pappas%2C+Eleftherios+P%22">Pappas, Eleftherios P</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AU" term="%22Logothetis%2C+Andreas%22">Logothetis, Andreas</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AU" term="%22Koutsouveli%2C+Efi%22">Koutsouveli, Efi</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AU" term="%22Pantelis%2C+Evaggelos%22">Pantelis, Evaggelos</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AU" term="%22Papagiannis%2C+Panagiotis%22">Papagiannis, Panagiotis</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AU" term="%22Karaiskos%2C+Pantelis%22">Karaiskos, Pantelis</searchLink><relatesTo>1</relatesTo>, <i>pkaraisk@med.uoa.gr</i>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Journal+of+Applied+Clinical+Medical+Physics%22">Journal of Applied Clinical Medical Physics</searchLink>; Mar2020, Vol. 21 Issue 3, p32-44, 13p
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=aci&AN=142266710
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1002/acm2.12815
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 13
        StartPage: 32
    Titles:
      – TitleFull: Dosimetric impact of rotational errors on the quality of VMAT‐SRS for multiple brain metastases: Comparison between single‐ and two‐isocenter treatment planning techniques.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Prentou, Georgia
      – PersonEntity:
          Name:
            NameFull: Pappas, Eleftherios P
      – PersonEntity:
          Name:
            NameFull: Logothetis, Andreas
      – PersonEntity:
          Name:
            NameFull: Koutsouveli, Efi
      – PersonEntity:
          Name:
            NameFull: Pantelis, Evaggelos
      – PersonEntity:
          Name:
            NameFull: Papagiannis, Panagiotis
      – PersonEntity:
          Name:
            NameFull: Karaiskos, Pantelis
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 03
              Text: Mar2020
              Type: published
              Y: 2020
          Identifiers:
            – Type: issn-print
              Value: 15269914
          Numbering:
            – Type: volume
              Value: 21
            – Type: issue
              Value: 3
          Titles:
            – TitleFull: Journal of Applied Clinical Medical Physics
              Type: main
ResultId 1