Physicists should perform reference planning for CBCT guided online adaptive radiotherapy.
Saved in:
| Title: | Physicists should perform reference planning for CBCT guided online adaptive radiotherapy. |
|---|---|
| Authors: | Lin, Mu‐Han1, Kavanaugh, James A.2, Kim, Minsun3, Cardenas, Carlos E.4, Rong, Yi5, rong.yi@mayo.edu |
| Source: | Journal of Applied Clinical Medical Physics; Oct2023, Vol. 24 Issue 10, p1-7, 7p |
| Database: | Applied Science & Technology Source |
| FullText | Text: Availability: 0 |
|---|---|
| Header | DbId: aci DbLabel: Applied Science & Technology Source An: 172875252 AccessLevel: 2 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Physicists should perform reference planning for CBCT guided online adaptive radiotherapy. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AU" term="%22Lin%2C+Mu‐Han%22">Lin, Mu‐Han</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AU" term="%22Kavanaugh%2C+James+A%2E%22">Kavanaugh, James A.</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AU" term="%22Kim%2C+Minsun%22">Kim, Minsun</searchLink><relatesTo>3</relatesTo><br /><searchLink fieldCode="AU" term="%22Cardenas%2C+Carlos+E%2E%22">Cardenas, Carlos E.</searchLink><relatesTo>4</relatesTo><br /><searchLink fieldCode="AU" term="%22Rong%2C+Yi%22">Rong, Yi</searchLink><relatesTo>5</relatesTo>, <i>rong.yi@mayo.edu</i> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Journal+of+Applied+Clinical+Medical+Physics%22">Journal of Applied Clinical Medical Physics</searchLink>; Oct2023, Vol. 24 Issue 10, p1-7, 7p |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=aci&AN=172875252 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1002/acm2.14163 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 7 StartPage: 1 Titles: – TitleFull: Physicists should perform reference planning for CBCT guided online adaptive radiotherapy. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Lin, Mu‐Han – PersonEntity: Name: NameFull: Kavanaugh, James A. – PersonEntity: Name: NameFull: Kim, Minsun – PersonEntity: Name: NameFull: Cardenas, Carlos E. – PersonEntity: Name: NameFull: Rong, Yi IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 10 Text: Oct2023 Type: published Y: 2023 Identifiers: – Type: issn-print Value: 15269914 Numbering: – Type: volume Value: 24 – Type: issue Value: 10 Titles: – TitleFull: Journal of Applied Clinical Medical Physics Type: main |
| ResultId | 1 |