The Usefulness of the Glucose Management Indicator in Evaluating the Quality of Glycemic Control in Patients with Type 1 Diabetes Using Continuous Glucose Monitoring Sensors: A Cross-Sectional, Multicenter Study.
Saved in:
| Title: | The Usefulness of the Glucose Management Indicator in Evaluating the Quality of Glycemic Control in Patients with Type 1 Diabetes Using Continuous Glucose Monitoring Sensors: A Cross-Sectional, Multicenter Study. |
|---|---|
| Authors: | Lazar, Sandra1,2,3, Potre, Ovidiu1,2,4, potre.ovidiu@umft.ro, Ionita, Ioana1,2,3,4, Reurean-Pintilei, Delia-Viola4,5,6, Timar, Romulus3,5,7,8, Herascu, Andreea3,6,7,8, Avram, Vlad Florian3,7,8, Timar, Bogdan3,7,8 |
| Source: | Biosensors (2079-6374); Mar2025, Vol. 15 Issue 3, p190, 16p |
| Database: | Applied Science & Technology Source |
|
Full text is not displayed to guests.
Login for full access.
|
|
| FullText | Links: – Type: pdflink Text: Availability: 1 |
|---|---|
| Header | DbId: aci DbLabel: Applied Science & Technology Source An: 184103655 AccessLevel: 2 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: The Usefulness of the Glucose Management Indicator in Evaluating the Quality of Glycemic Control in Patients with Type 1 Diabetes Using Continuous Glucose Monitoring Sensors: A Cross-Sectional, Multicenter Study. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AU" term="%22Lazar%2C+Sandra%22">Lazar, Sandra</searchLink><relatesTo>1,2,3</relatesTo><br /><searchLink fieldCode="AU" term="%22Potre%2C+Ovidiu%22">Potre, Ovidiu</searchLink><relatesTo>1,2,4</relatesTo>, <i>potre.ovidiu@umft.ro</i><br /><searchLink fieldCode="AU" term="%22Ionita%2C+Ioana%22">Ionita, Ioana</searchLink><relatesTo>1,2,3,4</relatesTo><br /><searchLink fieldCode="AU" term="%22Reurean-Pintilei%2C+Delia-Viola%22">Reurean-Pintilei, Delia-Viola</searchLink><relatesTo>4,5,6</relatesTo><br /><searchLink fieldCode="AU" term="%22Timar%2C+Romulus%22">Timar, Romulus</searchLink><relatesTo>3,5,7,8</relatesTo><br /><searchLink fieldCode="AU" term="%22Herascu%2C+Andreea%22">Herascu, Andreea</searchLink><relatesTo>3,6,7,8</relatesTo><br /><searchLink fieldCode="AU" term="%22Avram%2C+Vlad+Florian%22">Avram, Vlad Florian</searchLink><relatesTo>3,7,8</relatesTo><br /><searchLink fieldCode="AU" term="%22Timar%2C+Bogdan%22">Timar, Bogdan</searchLink><relatesTo>3,7,8</relatesTo> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Biosensors+%282079-6374%29%22">Biosensors (2079-6374)</searchLink>; Mar2025, Vol. 15 Issue 3, p190, 16p |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=aci&AN=184103655 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.3390/bios15030190 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 16 StartPage: 190 Titles: – TitleFull: The Usefulness of the Glucose Management Indicator in Evaluating the Quality of Glycemic Control in Patients with Type 1 Diabetes Using Continuous Glucose Monitoring Sensors: A Cross-Sectional, Multicenter Study. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Lazar, Sandra – PersonEntity: Name: NameFull: Potre, Ovidiu – PersonEntity: Name: NameFull: Ionita, Ioana – PersonEntity: Name: NameFull: Reurean-Pintilei, Delia-Viola – PersonEntity: Name: NameFull: Timar, Romulus – PersonEntity: Name: NameFull: Herascu, Andreea – PersonEntity: Name: NameFull: Avram, Vlad Florian – PersonEntity: Name: NameFull: Timar, Bogdan IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 03 Text: Mar2025 Type: published Y: 2025 Identifiers: – Type: issn-print Value: 20796374 Numbering: – Type: volume Value: 15 – Type: issue Value: 3 Titles: – TitleFull: Biosensors (2079-6374) Type: main |
| ResultId | 1 |