Accuracy of a Novel Transcutaneous PCO2 and PO2 Sensor with Optical PO2 Measurement in Neonatal Intensive Care: A Single-Centre Prospective Clinical Trial.
Saved in:
| Title: | Accuracy of a Novel Transcutaneous PCO |
|---|---|
| Authors: | Baumann, Philipp1,2 (AUTHOR), Gotta, Verena3 (AUTHOR), Adzikah, Stephanie1 (AUTHOR), Bernet, Vera1,2,4 (AUTHOR) |
| Source: | Neonatology (16617800). 2022, Vol. 119 Issue 2, p230-237. 8p. |
| Database: | Academic Search Ultimate |
|
Full text is not displayed to guests.
Login for full access.
|
|
| FullText | Links: – Type: pdflink Text: Availability: 1 |
|---|---|
| Header | DbId: asn DbLabel: Academic Search Ultimate An: 155930850 AccessLevel: 2 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Accuracy of a Novel Transcutaneous PCO<subscript>2</subscript> and PO<subscript>2</subscript> Sensor with Optical PO<subscript>2</subscript> Measurement in Neonatal Intensive Care: A Single-Centre Prospective Clinical Trial. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Baumann%2C+Philipp%22">Baumann, Philipp</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Gotta%2C+Verena%22">Gotta, Verena</searchLink><relatesTo>3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Adzikah%2C+Stephanie%22">Adzikah, Stephanie</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Bernet%2C+Vera%22">Bernet, Vera</searchLink><relatesTo>1,2,4</relatesTo> (AUTHOR) – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Neonatology+%2816617800%29%22">Neonatology (16617800)</searchLink>. 2022, Vol. 119 Issue 2, p230-237. 8p. |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=asn&AN=155930850 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1159/000521809 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 8 StartPage: 230 Titles: – TitleFull: Accuracy of a Novel Transcutaneous PCO2 and PO2 Sensor with Optical PO2 Measurement in Neonatal Intensive Care: A Single-Centre Prospective Clinical Trial. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Baumann, Philipp – PersonEntity: Name: NameFull: Gotta, Verena – PersonEntity: Name: NameFull: Adzikah, Stephanie – PersonEntity: Name: NameFull: Bernet, Vera IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 03 Text: 2022 Type: published Y: 2022 Identifiers: – Type: issn-print Value: 16617800 Numbering: – Type: volume Value: 119 – Type: issue Value: 2 Titles: – TitleFull: Neonatology (16617800) Type: main |
| ResultId | 1 |