CT colonography : defining performance and interventions to improve interpretation

Saved in:
Bibliographic Details
Title: CT colonography : defining performance and interventions to improve interpretation
Authors: Burling, David
Committee Members: Halligan, Steve
Summary: CT colonography is now widely regarded as the optimal radiological technique for colonic examination. However, performance characteristics, particularly relating to interpretation accuracy, interpretation times and polyp measurement have been derived primarily from academic centres in the USA. For successful implementation of CT colonography, such performance characteristics must be generalisable to non-academic centres, different patient populations in different geographical locations, and different clinical environments. This thesis aims to investigate current UK implementation and to determine the interpretative performance of observers across the UK and Europe, focussing on those interventions influencing reader accuracy and polyp measurement. The first chapter reviews the technique, diagnostic performance and clinical role of CT colonography. It is followed by two surveys revealing CT colonography is widely available across the UK NHS, and that hitherto unsuspected complications do occur, although CT colonography appears relatively safe in routine clinical practice when compared to alternatives. The effect of directed training on reader performance is investigated in a multi-centre European study and shows that experienced radiologists are significantly more accurate and time-efficient when reporting CT colonography compared to specifically trained but less experienced radiologists and radiographers. A subsequent study also shows they are more accurate than radiologists offering CT colonography in UK clinical practice routinely. Trained radiographers can perform as well as their radiologist counterparts. The accuracy of polyp measurement is investigated and the effect of different visualisation displays determined. Results suggest that an optimised 2D display utilising a 'colon CT window' should be recommended. Finally, we show that an automatic measurement software tool improves inter and intra-observer agreement for polyp measurement 'in vitro' although the benefit for in-vivo measurement is less clear.
URL: https://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.439390
Database: OpenDissertations
FullText Text:
  Availability: 0
Header DbId: ddu
DbLabel: OpenDissertations
An: ddu.oai.ethos.bl.uk.439390
AccessLevel: 6
PubType: Dissertation/ Thesis
PubTypeId: dissertation
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: CT colonography : defining performance and interventions to improve interpretation
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Burling%2C+David%22">Burling, David</searchLink>
– Name: Author
  Label: Committee Members
  Group: Au
  Data: <searchLink fieldCode="CO" term="%22Halligan%2C+Steve%22">Halligan, Steve</searchLink>
– Name: Abstract
  Label: Summary
  Group: Ab
  Data: CT colonography is now widely regarded as the optimal radiological technique for colonic examination. However, performance characteristics, particularly relating to interpretation accuracy, interpretation times and polyp measurement have been derived primarily from academic centres in the USA. For successful implementation of CT colonography, such performance characteristics must be generalisable to non-academic centres, different patient populations in different geographical locations, and different clinical environments. This thesis aims to investigate current UK implementation and to determine the interpretative performance of observers across the UK and Europe, focussing on those interventions influencing reader accuracy and polyp measurement. The first chapter reviews the technique, diagnostic performance and clinical role of CT colonography. It is followed by two surveys revealing CT colonography is widely available across the UK NHS, and that hitherto unsuspected complications do occur, although CT colonography appears relatively safe in routine clinical practice when compared to alternatives. The effect of directed training on reader performance is investigated in a multi-centre European study and shows that experienced radiologists are significantly more accurate and time-efficient when reporting CT colonography compared to specifically trained but less experienced radiologists and radiographers. A subsequent study also shows they are more accurate than radiologists offering CT colonography in UK clinical practice routinely. Trained radiographers can perform as well as their radiologist counterparts. The accuracy of polyp measurement is investigated and the effect of different visualisation displays determined. Results suggest that an optimised 2D display utilising a 'colon CT window' should be recommended. Finally, we show that an automatic measurement software tool improves inter and intra-observer agreement for polyp measurement 'in vitro' although the benefit for in-vivo measurement is less clear.
– Name: URL
  Label: URL
  Group: URL
  Data: <link linkTarget="URL" linkTerm="https://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.439390" linkWindow="_blank">https://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.439390</link>
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=ddu&AN=ddu.oai.ethos.bl.uk.439390
RecordInfo BibRecord:
  BibEntity:
    Languages:
      – Code: eng
        Text: English
    Subjects:
      – SubjectFull: 616.342075722
        Type: general
    Titles:
      – TitleFull: CT colonography : defining performance and interventions to improve interpretation
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Burling, David
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 01
              Type: published
              Y: 2006
ResultId 1