Fin spacing interaction in fluidized bed heat exchangers

Saved in:
Bibliographic Details
Title: Fin spacing interaction in fluidized bed heat exchangers
Authors: Al-Ali, Burhan M. A.
Summary: The work presented in this thesis is concerned with the heat transfer performance of a single horizontal bare tube and a variety of finned tubes immersed in a shallow air fluidized bed. Results of experimental investigations with the bare tube indicate that the tube position in the bed influences its performance narticularly where fine bed materials are used. In some cases the maximum heat transfer is obtained with the tube in the particle cloud just above the dense phase fluidized bed - a phenomenon that has not been previously observed. This was attributed to the unusual particle circulation in shallow beds. The data is also presented in dimensionless correlations which may be useful for design purposes. A close approximation to the bare tube data can be obtained by using thetransient heating of a spherical robe and this provides a valuable way of accumulating a lot of data very rapidly. The experimental data on finned tubes shows that a fin spacing less than twenty times the average particle diameter can cause a significant reduction in heat transfer due to the interaction which takes place between the particles and the surface of the fins. Furthermore, evidence is provided to show that particle shape plays an important part in the interaction with spherical particles being superior to angular particles at low fin spacing/particle diameter ratio. The finned tube data is less sensitive to tube position in the bed than bare tubes and the best performance is when the tube is positioned at the distributor. A reduction in bed depth decreases the thermal performance of the finned tube but in many practical installations the reduction in pressure drop might more than comnensate for the reduced heat flux. Information is also provided on the theoretical uerformance of fins and the effect of the root contact area between the fins and the tube was investigated.
URL: https://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.447187
Database: OpenDissertations
FullText Text:
  Availability: 0
Header DbId: ddu
DbLabel: OpenDissertations
An: ddu.oai.ethos.bl.uk.447187
AccessLevel: 6
PubType: Dissertation/ Thesis
PubTypeId: dissertation
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Fin spacing interaction in fluidized bed heat exchangers
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Al-Ali%2C+Burhan+M%2E+A%2E%22">Al-Ali, Burhan M. A.</searchLink>
– Name: Abstract
  Label: Summary
  Group: Ab
  Data: The work presented in this thesis is concerned with the heat transfer performance of a single horizontal bare tube and a variety of finned tubes immersed in a shallow air fluidized bed. Results of experimental investigations with the bare tube indicate that the tube position in the bed influences its performance narticularly where fine bed materials are used. In some cases the maximum heat transfer is obtained with the tube in the particle cloud just above the dense phase fluidized bed - a phenomenon that has not been previously observed. This was attributed to the unusual particle circulation in shallow beds. The data is also presented in dimensionless correlations which may be useful for design purposes. A close approximation to the bare tube data can be obtained by using thetransient heating of a spherical robe and this provides a valuable way of accumulating a lot of data very rapidly. The experimental data on finned tubes shows that a fin spacing less than twenty times the average particle diameter can cause a significant reduction in heat transfer due to the interaction which takes place between the particles and the surface of the fins. Furthermore, evidence is provided to show that particle shape plays an important part in the interaction with spherical particles being superior to angular particles at low fin spacing/particle diameter ratio. The finned tube data is less sensitive to tube position in the bed than bare tubes and the best performance is when the tube is positioned at the distributor. A reduction in bed depth decreases the thermal performance of the finned tube but in many practical installations the reduction in pressure drop might more than comnensate for the reduced heat flux. Information is also provided on the theoretical uerformance of fins and the effect of the root contact area between the fins and the tube was investigated.
– Name: URL
  Label: URL
  Group: URL
  Data: <link linkTarget="URL" linkTerm="https://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.447187" linkWindow="_blank">https://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.447187</link>
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=ddu&AN=ddu.oai.ethos.bl.uk.447187
RecordInfo BibRecord:
  BibEntity:
    Languages:
      – Code: eng
        Text: English
    Subjects:
      – SubjectFull: 660.2842
        Type: general
      – SubjectFull: Mechanical Engineering
        Type: general
    Titles:
      – TitleFull: Fin spacing interaction in fluidized bed heat exchangers
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Al-Ali, Burhan M. A.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 01
              Type: published
              Y: 1976
ResultId 1