Innovations at the MT 25 microtron aimed at applications in photon activation analysis.

Saved in:
Bibliographic Details
Title: Innovations at the MT 25 microtron aimed at applications in photon activation analysis.
Authors: Krist, Pavel1 krist@ujf.cas.cz, Horák, Zbyněk1, Mizera, Jiří1, Chvátil, David1, Vognar, Miroslav1, Řanda, Zdeněk1
Source: Journal of Radioanalytical & Nuclear Chemistry. Apr2015, Vol. 304 Issue 1, p183-188. 6p. 1 Color Photograph, 4 Diagrams, 2 Charts.
Subjects: Technological innovations, Microtrons, Nuclear activation analysis, Photon emission, Radioactive nuclear beams, Fuzzy systems
Abstract: Microtron MT 25 is an effective source of high energy photon radiation in photon activation analysis (PAA). Recent modernization of MT 25 was aimed at upgrading its parameters such as the mean accelerated electron current, quality of the beam and irradiation fields, and long-run operation stability and reliability. A fuzzy system for automated control of the current and energy of the accelerated electrons has been designed. Installation of an automated pneumatic tube delivery system for rapid sample transport between the beam position and detector will provide extension of the analytical range of PAA in the short time irradiation mode. [ABSTRACT FROM AUTHOR]
Copyright of Journal of Radioanalytical & Nuclear Chemistry is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Links:
  – Type: pdflink
Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 101679838
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Innovations at the MT 25 microtron aimed at applications in photon activation analysis.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Krist%2C+Pavel%22">Krist, Pavel</searchLink><relatesTo>1</relatesTo><i> krist@ujf.cas.cz</i><br /><searchLink fieldCode="AR" term="%22Horák%2C+Zbyněk%22">Horák, Zbyněk</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Mizera%2C+Jiří%22">Mizera, Jiří</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Chvátil%2C+David%22">Chvátil, David</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Vognar%2C+Miroslav%22">Vognar, Miroslav</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Řanda%2C+Zdeněk%22">Řanda, Zdeněk</searchLink><relatesTo>1</relatesTo>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Journal+of+Radioanalytical+%26+Nuclear+Chemistry%22">Journal of Radioanalytical & Nuclear Chemistry</searchLink>. Apr2015, Vol. 304 Issue 1, p183-188. 6p. 1 Color Photograph, 4 Diagrams, 2 Charts.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Technological+innovations%22">Technological innovations</searchLink><br /><searchLink fieldCode="DE" term="%22Microtrons%22">Microtrons</searchLink><br /><searchLink fieldCode="DE" term="%22Nuclear+activation+analysis%22">Nuclear activation analysis</searchLink><br /><searchLink fieldCode="DE" term="%22Photon+emission%22">Photon emission</searchLink><br /><searchLink fieldCode="DE" term="%22Radioactive+nuclear+beams%22">Radioactive nuclear beams</searchLink><br /><searchLink fieldCode="DE" term="%22Fuzzy+systems%22">Fuzzy systems</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Microtron MT 25 is an effective source of high energy photon radiation in photon activation analysis (PAA). Recent modernization of MT 25 was aimed at upgrading its parameters such as the mean accelerated electron current, quality of the beam and irradiation fields, and long-run operation stability and reliability. A fuzzy system for automated control of the current and energy of the accelerated electrons has been designed. Installation of an automated pneumatic tube delivery system for rapid sample transport between the beam position and detector will provide extension of the analytical range of PAA in the short time irradiation mode. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Journal of Radioanalytical & Nuclear Chemistry is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=101679838
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1007/s10967-014-3578-z
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 6
        StartPage: 183
    Subjects:
      – SubjectFull: Technological innovations
        Type: general
      – SubjectFull: Microtrons
        Type: general
      – SubjectFull: Nuclear activation analysis
        Type: general
      – SubjectFull: Photon emission
        Type: general
      – SubjectFull: Radioactive nuclear beams
        Type: general
      – SubjectFull: Fuzzy systems
        Type: general
    Titles:
      – TitleFull: Innovations at the MT 25 microtron aimed at applications in photon activation analysis.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Krist, Pavel
      – PersonEntity:
          Name:
            NameFull: Horák, Zbyněk
      – PersonEntity:
          Name:
            NameFull: Mizera, Jiří
      – PersonEntity:
          Name:
            NameFull: Chvátil, David
      – PersonEntity:
          Name:
            NameFull: Vognar, Miroslav
      – PersonEntity:
          Name:
            NameFull: Řanda, Zdeněk
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 04
              Text: Apr2015
              Type: published
              Y: 2015
          Identifiers:
            – Type: issn-print
              Value: 02365731
          Numbering:
            – Type: volume
              Value: 304
            – Type: issue
              Value: 1
          Titles:
            – TitleFull: Journal of Radioanalytical & Nuclear Chemistry
              Type: main
ResultId 1