Coordinated direct current matching control strategy for multi-terminal DC transmission systems with integrated wind farms.

Saved in:
Bibliographic Details
Title: Coordinated direct current matching control strategy for multi-terminal DC transmission systems with integrated wind farms.
Authors: Zhu, Jiebei1 Jiebei.zhu@nationalgrid.com, Booth, Campbell D.2 Campbell.d.booth@strath.ac.uk, Adam, Grain P.2 Grain.adam@strath.ac.uk, Roscoe, Andrew J.2 Andrew.j.roscoe@strath.ac.uk
Source: Electric Power Systems Research. Jul2015, Vol. 124, p55-64. 10p.
Subjects: Direct current in electric power distribution, Electric power transmission, Wind power plants, Smart power grids, Electric power plants, Renewable energy sources
Abstract: A new direct current matching control (DCMC) scheme is proposed in this paper. The scheme is ideally suited for the integration of a large number of wind farms with AC grid systems via a multi-terminal HVDC (MTDC) network incorporating several grid-side converters. The proposed DCMC, which matches, in a near-instantaneous fashion, the cumulative injected DC currents from all wind farms with the total of the output DC currents to the AC grids (via inverters) by communicating real-time data between all terminals, is an improvement upon and potential replacement for conventional DC voltage droop and master–slave control strategies. Through the utilization of a wide-area supervisory control and data acquisition (WA-SCADA) system, the proposed DCMC aims to enhance MTDC network voltage stability and facilitate flexible power dispatch to the supplied AC grids, while maximizing the total amount of generated wind power and offering more flexibility in terms of the ability for wind farms to independently control and maximize their outputs without any requirement for output to be constrained. A six-terminal MTDC system connecting three wind farms to three independent mainland AC grids is used to validate the proposed DCMC and compare its performance with conventional control strategies, three simulation studies are carried out to test and verify the DCMC. [ABSTRACT FROM AUTHOR]
Copyright of Electric Power Systems Research is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Description
Abstract:A new direct current matching control (DCMC) scheme is proposed in this paper. The scheme is ideally suited for the integration of a large number of wind farms with AC grid systems via a multi-terminal HVDC (MTDC) network incorporating several grid-side converters. The proposed DCMC, which matches, in a near-instantaneous fashion, the cumulative injected DC currents from all wind farms with the total of the output DC currents to the AC grids (via inverters) by communicating real-time data between all terminals, is an improvement upon and potential replacement for conventional DC voltage droop and master–slave control strategies. Through the utilization of a wide-area supervisory control and data acquisition (WA-SCADA) system, the proposed DCMC aims to enhance MTDC network voltage stability and facilitate flexible power dispatch to the supplied AC grids, while maximizing the total amount of generated wind power and offering more flexibility in terms of the ability for wind farms to independently control and maximize their outputs without any requirement for output to be constrained. A six-terminal MTDC system connecting three wind farms to three independent mainland AC grids is used to validate the proposed DCMC and compare its performance with conventional control strategies, three simulation studies are carried out to test and verify the DCMC. [ABSTRACT FROM AUTHOR]
ISSN:03787796
DOI:10.1016/j.epsr.2015.02.015