Improved Dynamic Response Assessment for Intra-Articular Injected Iron Oxide Nanoparticles.

Saved in:
Bibliographic Details
Title: Improved Dynamic Response Assessment for Intra-Articular Injected Iron Oxide Nanoparticles.
Authors: Crowe, L. A.1 lindsey.crowe@hcuge.ch, Tobalem, F.1, Gramoun, A.1, Delattre, B. M. A.1, Grosdemange, K.1, Salaklang, J.2, Redjem, A.2, Petri-Fink, A.2, Hofmann, H.3, Vallée, J. -P.1
Source: Magnetic Resonance in Medicine. Nov2012, Vol. 68 Issue 5, p1544-1552. 9p.
Abstract: The emerging importance of nanoparticle technology, including iron oxide nanoparticles for monitoring development, progression, and treatment of inflammatory diseases such as arthritis, drives development of imaging techniques. Studies require an imaging protocol that is sensitive and quantifiable for the detection of iron oxide over a wide range of concentrations. Conventional signal loss measurements of iron oxide nanoparticle containing tissues saturate at medium concentrations and show a nonlinear/nonproportional intensity to concentration profile due to the competing effects of T1 and T2 relaxation. A concentration calibration phantom and an in vivo study of intra-articular injection in a rat knee of known concentrations of iron oxide were assessed using the difference-ultrashort echo time sequence giving a positive, quantifiable, unambiguous iron signal and monotonic, increasing concentration response over a wide concentration range in the phantom with limited susceptibility artifacts and high contrast in vivo to all other tissues. This improved dynamic response to concentration opens possibilities for quantification due to its linear nature at physiologically relevant concentrations. [ABSTRACT FROM AUTHOR]
Copyright of Magnetic Resonance in Medicine is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Links:
  – Type: pdflink
Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 103682843
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Improved Dynamic Response Assessment for Intra-Articular Injected Iron Oxide Nanoparticles.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Crowe%2C+L%2E+A%2E%22">Crowe, L. A.</searchLink><relatesTo>1</relatesTo><i> lindsey.crowe@hcuge.ch</i><br /><searchLink fieldCode="AR" term="%22Tobalem%2C+F%2E%22">Tobalem, F.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Gramoun%2C+A%2E%22">Gramoun, A.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Delattre%2C+B%2E+M%2E+A%2E%22">Delattre, B. M. A.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Grosdemange%2C+K%2E%22">Grosdemange, K.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Salaklang%2C+J%2E%22">Salaklang, J.</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Redjem%2C+A%2E%22">Redjem, A.</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Petri-Fink%2C+A%2E%22">Petri-Fink, A.</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Hofmann%2C+H%2E%22">Hofmann, H.</searchLink><relatesTo>3</relatesTo><br /><searchLink fieldCode="AR" term="%22Vallée%2C+J%2E+-P%2E%22">Vallée, J. -P.</searchLink><relatesTo>1</relatesTo>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Magnetic+Resonance+in+Medicine%22">Magnetic Resonance in Medicine</searchLink>. Nov2012, Vol. 68 Issue 5, p1544-1552. 9p.
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: The emerging importance of nanoparticle technology, including iron oxide nanoparticles for monitoring development, progression, and treatment of inflammatory diseases such as arthritis, drives development of imaging techniques. Studies require an imaging protocol that is sensitive and quantifiable for the detection of iron oxide over a wide range of concentrations. Conventional signal loss measurements of iron oxide nanoparticle containing tissues saturate at medium concentrations and show a nonlinear/nonproportional intensity to concentration profile due to the competing effects of T1 and T2 relaxation. A concentration calibration phantom and an in vivo study of intra-articular injection in a rat knee of known concentrations of iron oxide were assessed using the difference-ultrashort echo time sequence giving a positive, quantifiable, unambiguous iron signal and monotonic, increasing concentration response over a wide concentration range in the phantom with limited susceptibility artifacts and high contrast in vivo to all other tissues. This improved dynamic response to concentration opens possibilities for quantification due to its linear nature at physiologically relevant concentrations. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Magnetic Resonance in Medicine is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=103682843
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1002/mrm.24166
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 9
        StartPage: 1544
    Titles:
      – TitleFull: Improved Dynamic Response Assessment for Intra-Articular Injected Iron Oxide Nanoparticles.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Crowe, L. A.
      – PersonEntity:
          Name:
            NameFull: Tobalem, F.
      – PersonEntity:
          Name:
            NameFull: Gramoun, A.
      – PersonEntity:
          Name:
            NameFull: Delattre, B. M. A.
      – PersonEntity:
          Name:
            NameFull: Grosdemange, K.
      – PersonEntity:
          Name:
            NameFull: Salaklang, J.
      – PersonEntity:
          Name:
            NameFull: Redjem, A.
      – PersonEntity:
          Name:
            NameFull: Petri-Fink, A.
      – PersonEntity:
          Name:
            NameFull: Hofmann, H.
      – PersonEntity:
          Name:
            NameFull: Vallée, J. -P.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 11
              Text: Nov2012
              Type: published
              Y: 2012
          Identifiers:
            – Type: issn-print
              Value: 07403194
          Numbering:
            – Type: volume
              Value: 68
            – Type: issue
              Value: 5
          Titles:
            – TitleFull: Magnetic Resonance in Medicine
              Type: main
ResultId 1