Diffusion-weighted and T2-weighted MR imaging for colorectal liver metastases detection in a rat model at 7 T: a comparative study using histological examination as reference.

Saved in:
Bibliographic Details
Title: Diffusion-weighted and T2-weighted MR imaging for colorectal liver metastases detection in a rat model at 7 T: a comparative study using histological examination as reference.
Authors: Wagner, Mathilde (AUTHOR), Maggiori, Léon (AUTHOR), Ronot, Maxime (AUTHOR), Paradis, Valérie (AUTHOR), Vilgrain, Valérie (AUTHOR), Panis, Yves (AUTHOR), Van Beers, Bernard E (AUTHOR)
Source: European Radiology. Aug2013, Vol. 23 Issue 8, p2156-2164. 9p.
Abstract: Objectives: To compare diffusion-weighted (DW) and T2-weighted MR imaging in detecting colorectal liver metastases in a rat model, using histological examination as a reference method.Methods: Eighteen rats had four liver injections of colon cancer cells. MR examinations at 7 T included FSE-T2-weighted imaging and SE-DW MR imaging (b = 0, 20 and 150 s/mm(2)) and were analysed by two independent readers. Histological examination was performed on 0.4-mm slices. McNemar's test was used to compare the sensitivities and the Wilcoxon matched pairs test to compare the average number of false-positives per rat.Results: One hundred and sixty-six liver metastases were identified on histological examination. The sensitivity in detecting liver metastases was significantly higher on DW MR than on T2-weighted images (99/166 (60 %) (reader 1) and 92/166 (55 %) (reader 2) versus 77/166 (46 %), P ≤ 0.001), without an increase in false-positives per rat (P = 0.773/P = 0.850). After stratification according to metastasis diameter, DW MR imaging had a significantly higher sensitivity than T2-weighted imaging only for metastases with a diameter (0.6-1.2 mm) similar to that of the spatial resolution of MR imaging in the current study.Conclusions: This MR study with histological correlations shows the higher sensitivity of DW relative to T2-weighted imaging at 7 T for detecting liver metastases, especially small ones.Key Points: • Diffusion weighted (DW) sequences are increasingly used in magnetic resonance imaging (MRI). • DW has higher sensitivity for liver metastases than T2-weighted imaging at 7 T. • This increase in sensitivity is especially marked for small liver metastasis detection. • This higher sensitivity is confirmed in an animal model with histological correlation. • DW imaging has the potential for earlier diagnosis of small liver metastases. [ABSTRACT FROM AUTHOR]
Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
URL: 88901099
Database: Engineering Source
FullText Links:
  – Type: pdflink
Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 104080231
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Diffusion-weighted and T2-weighted MR imaging for colorectal liver metastases detection in a rat model at 7 T: a comparative study using histological examination as reference.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Wagner%2C+Mathilde%22">Wagner, Mathilde</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Maggiori%2C+Léon%22">Maggiori, Léon</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Ronot%2C+Maxime%22">Ronot, Maxime</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Paradis%2C+Valérie%22">Paradis, Valérie</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Vilgrain%2C+Valérie%22">Vilgrain, Valérie</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Panis%2C+Yves%22">Panis, Yves</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Van+Beers%2C+Bernard+E%22">Van Beers, Bernard E</searchLink> (AUTHOR)
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22European+Radiology%22">European Radiology</searchLink>. Aug2013, Vol. 23 Issue 8, p2156-2164. 9p.
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: <bold>Objectives: </bold>To compare diffusion-weighted (DW) and T2-weighted MR imaging in detecting colorectal liver metastases in a rat model, using histological examination as a reference method.<bold>Methods: </bold>Eighteen rats had four liver injections of colon cancer cells. MR examinations at 7 T included FSE-T2-weighted imaging and SE-DW MR imaging (b = 0, 20 and 150 s/mm(2)) and were analysed by two independent readers. Histological examination was performed on 0.4-mm slices. McNemar's test was used to compare the sensitivities and the Wilcoxon matched pairs test to compare the average number of false-positives per rat.<bold>Results: </bold>One hundred and sixty-six liver metastases were identified on histological examination. The sensitivity in detecting liver metastases was significantly higher on DW MR than on T2-weighted images (99/166 (60 %) (reader 1) and 92/166 (55 %) (reader 2) versus 77/166 (46 %), P ≤ 0.001), without an increase in false-positives per rat (P = 0.773/P = 0.850). After stratification according to metastasis diameter, DW MR imaging had a significantly higher sensitivity than T2-weighted imaging only for metastases with a diameter (0.6-1.2 mm) similar to that of the spatial resolution of MR imaging in the current study.<bold>Conclusions: </bold>This MR study with histological correlations shows the higher sensitivity of DW relative to T2-weighted imaging at 7 T for detecting liver metastases, especially small ones.<bold>Key Points: </bold>• Diffusion weighted (DW) sequences are increasingly used in magnetic resonance imaging (MRI). • DW has higher sensitivity for liver metastases than T2-weighted imaging at 7 T. • This increase in sensitivity is especially marked for small liver metastasis detection. • This higher sensitivity is confirmed in an animal model with histological correlation. • DW imaging has the potential for earlier diagnosis of small liver metastases. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
– Name: URL
  Label: URL
  Group: URL
  Data: <link linkTarget="URL" linkTerm="88901099" linkWindow="_blank">88901099</link>
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=104080231
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1007/s00330-013-2789-y
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 9
        StartPage: 2156
    Titles:
      – TitleFull: Diffusion-weighted and T2-weighted MR imaging for colorectal liver metastases detection in a rat model at 7 T: a comparative study using histological examination as reference.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Wagner, Mathilde
      – PersonEntity:
          Name:
            NameFull: Maggiori, Léon
      – PersonEntity:
          Name:
            NameFull: Ronot, Maxime
      – PersonEntity:
          Name:
            NameFull: Paradis, Valérie
      – PersonEntity:
          Name:
            NameFull: Vilgrain, Valérie
      – PersonEntity:
          Name:
            NameFull: Panis, Yves
      – PersonEntity:
          Name:
            NameFull: Van Beers, Bernard E
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 08
              Text: Aug2013
              Type: published
              Y: 2013
          Identifiers:
            – Type: issn-print
              Value: 09387994
          Numbering:
            – Type: volume
              Value: 23
            – Type: issue
              Value: 8
          Titles:
            – TitleFull: European Radiology
              Type: main
ResultId 1