Spectroscopic (multi-energy) CT distinguishes iodine and barium contrast material in MICE.

Saved in:
Bibliographic Details
Title: Spectroscopic (multi-energy) CT distinguishes iodine and barium contrast material in MICE.
Authors: Anderson NG (AUTHOR), Butler AP (AUTHOR), Scott NJ (AUTHOR), Cook NJ (AUTHOR), Butzer JS (AUTHOR), Schleich N (AUTHOR), Firsching M (AUTHOR), Grasset R (AUTHOR), de Ruiter N (AUTHOR), Campbell M (AUTHOR), Butler PH (AUTHOR), Anderson, N G1 (AUTHOR), Butler, A P (AUTHOR), Scott, N J A (AUTHOR), Cook, N J (AUTHOR), Butzer, J S (AUTHOR), Schleich, N (AUTHOR), Firsching, M (AUTHOR), Grasset, R (AUTHOR), de Ruiter, N (AUTHOR)
Source: European Radiology. Sep2010, Vol. 20 Issue 9, p2126-2134. 9p.
Abstract: Objective: Spectral CT differs from dual-energy CT by using a conventional X-ray tube and a photon-counting detector. We wished to produce 3D spectroscopic images of mice that distinguished calcium, iodine and barium.Methods: We developed a desktop spectral CT, dubbed MARS, based around the Medipix2 photon-counting energy-discriminating detector. The single conventional X-ray tube operated at constant voltage (75 kVp) and constant current (150 microA). We anaesthetised with ketamine six black mice (C57BL/6). We introduced iodinated contrast material and barium sulphate into the vascular system, alimentary tract and respiratory tract as we euthanised them. The mice were preserved in resin and imaged at four detector energy levels from 12 keV to 42 keV to include the K-edges of iodine (33.0 keV) and barium (37.4 keV). Principal component analysis was applied to reconstructed images to identify components with independent energy response, then displayed in 2D and 3D.Results: Iodinated and barium contrast material was spectrally distinct from soft tissue and bone in all six mice. Calcium, iodine and barium were displayed as separate channels on 3D colour images at <55 microm isotropic voxels.Conclusion: Spectral CT distinguishes contrast agents with K-edges only 4 keV apart. Multi-contrast imaging and molecular CT are potential future applications. [ABSTRACT FROM AUTHOR]
Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: egs
DbLabel: Engineering Source
An: 104914259
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Spectroscopic (multi-energy) CT distinguishes iodine and barium contrast material in MICE.
– Name: Author
  Label: Authors
  Group: Au
  Data: &lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Anderson+NG%22&quot;&gt;Anderson NG&lt;/searchLink&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Butler+AP%22&quot;&gt;Butler AP&lt;/searchLink&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Scott+NJ%22&quot;&gt;Scott NJ&lt;/searchLink&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Cook+NJ%22&quot;&gt;Cook NJ&lt;/searchLink&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Butzer+JS%22&quot;&gt;Butzer JS&lt;/searchLink&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Schleich+N%22&quot;&gt;Schleich N&lt;/searchLink&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Firsching+M%22&quot;&gt;Firsching M&lt;/searchLink&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Grasset+R%22&quot;&gt;Grasset R&lt;/searchLink&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22de+Ruiter+N%22&quot;&gt;de Ruiter N&lt;/searchLink&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Campbell+M%22&quot;&gt;Campbell M&lt;/searchLink&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Butler+PH%22&quot;&gt;Butler PH&lt;/searchLink&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Anderson%2C+N+G%22&quot;&gt;Anderson, N G&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Butler%2C+A+P%22&quot;&gt;Butler, A P&lt;/searchLink&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Scott%2C+N+J+A%22&quot;&gt;Scott, N J A&lt;/searchLink&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Cook%2C+N+J%22&quot;&gt;Cook, N J&lt;/searchLink&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Butzer%2C+J+S%22&quot;&gt;Butzer, J S&lt;/searchLink&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Schleich%2C+N%22&quot;&gt;Schleich, N&lt;/searchLink&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Firsching%2C+M%22&quot;&gt;Firsching, M&lt;/searchLink&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Grasset%2C+R%22&quot;&gt;Grasset, R&lt;/searchLink&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22de+Ruiter%2C+N%22&quot;&gt;de Ruiter, N&lt;/searchLink&gt; (AUTHOR)
– Name: TitleSource
  Label: Source
  Group: Src
  Data: &lt;searchLink fieldCode=&quot;JN&quot; term=&quot;%22European+Radiology%22&quot;&gt;European Radiology&lt;/searchLink&gt;. Sep2010, Vol. 20 Issue 9, p2126-2134. 9p.
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: &lt;bold&gt;Objective: &lt;/bold&gt;Spectral CT differs from dual-energy CT by using a conventional X-ray tube and a photon-counting detector. We wished to produce 3D spectroscopic images of mice that distinguished calcium, iodine and barium.&lt;bold&gt;Methods: &lt;/bold&gt;We developed a desktop spectral CT, dubbed MARS, based around the Medipix2 photon-counting energy-discriminating detector. The single conventional X-ray tube operated at constant voltage (75 kVp) and constant current (150 microA). We anaesthetised with ketamine six black mice (C57BL/6). We introduced iodinated contrast material and barium sulphate into the vascular system, alimentary tract and respiratory tract as we euthanised them. The mice were preserved in resin and imaged at four detector energy levels from 12 keV to 42 keV to include the K-edges of iodine (33.0 keV) and barium (37.4 keV). Principal component analysis was applied to reconstructed images to identify components with independent energy response, then displayed in 2D and 3D.&lt;bold&gt;Results: &lt;/bold&gt;Iodinated and barium contrast material was spectrally distinct from soft tissue and bone in all six mice. Calcium, iodine and barium were displayed as separate channels on 3D colour images at &lt;55 microm isotropic voxels.&lt;bold&gt;Conclusion: &lt;/bold&gt;Spectral CT distinguishes contrast agents with K-edges only 4 keV apart. Multi-contrast imaging and molecular CT are potential future applications. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: &lt;i&gt;Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder&#39;s express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.&lt;/i&gt; (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=104914259
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1007/s00330-010-1768-9
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 9
        StartPage: 2126
    Titles:
      – TitleFull: Spectroscopic (multi-energy) CT distinguishes iodine and barium contrast material in MICE.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Anderson NG
      – PersonEntity:
          Name:
            NameFull: Butler AP
      – PersonEntity:
          Name:
            NameFull: Scott NJ
      – PersonEntity:
          Name:
            NameFull: Cook NJ
      – PersonEntity:
          Name:
            NameFull: Butzer JS
      – PersonEntity:
          Name:
            NameFull: Schleich N
      – PersonEntity:
          Name:
            NameFull: Firsching M
      – PersonEntity:
          Name:
            NameFull: Grasset R
      – PersonEntity:
          Name:
            NameFull: de Ruiter N
      – PersonEntity:
          Name:
            NameFull: Campbell M
      – PersonEntity:
          Name:
            NameFull: Butler PH
      – PersonEntity:
          Name:
            NameFull: Anderson, N G
      – PersonEntity:
          Name:
            NameFull: Butler, A P
      – PersonEntity:
          Name:
            NameFull: Scott, N J A
      – PersonEntity:
          Name:
            NameFull: Cook, N J
      – PersonEntity:
          Name:
            NameFull: Butzer, J S
      – PersonEntity:
          Name:
            NameFull: Schleich, N
      – PersonEntity:
          Name:
            NameFull: Firsching, M
      – PersonEntity:
          Name:
            NameFull: Grasset, R
      – PersonEntity:
          Name:
            NameFull: de Ruiter, N
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 09
              Text: Sep2010
              Type: published
              Y: 2010
          Identifiers:
            – Type: issn-print
              Value: 09387994
          Numbering:
            – Type: volume
              Value: 20
            – Type: issue
              Value: 9
          Titles:
            – TitleFull: European Radiology
              Type: main
ResultId 1