MR angiography with parallel acquisition for assessment of the visceral arteries: comparison with conventional MR angiography and 64-detector-row computed tomography.
Saved in:
| Title: | MR angiography with parallel acquisition for assessment of the visceral arteries: comparison with conventional MR angiography and 64-detector-row computed tomography. |
|---|---|
| Authors: | Sutter R (AUTHOR), Heilmaier C (AUTHOR), Lutz AM (AUTHOR), Weishaupt D (AUTHOR), Seifert B (AUTHOR), Willmann JK (AUTHOR), Sutter, Reto1 (AUTHOR), Heilmaier, Christina (AUTHOR), Lutz, Amelie M (AUTHOR), Weishaupt, Dominik (AUTHOR), Seifert, Burkhardt (AUTHOR), Willmann, Jürgen K (AUTHOR) |
| Source: | European Radiology. Nov2009, Vol. 19 Issue 11, p2679-2688. 10p. |
| Abstract: | The purpose of the study was to retrospectively compare three-dimensional gadolinium-enhanced magnetic resonance angiography (conventional MRA) with MRA accelerated by a parallel acquisition technique (fast MRA) for the assessment of visceral arteries, using 64-detector-row computed tomography angiography (MDCTA) as the reference standard. Eighteen patients underwent fast MRA (imaging time 17 s), conventional MRA (29 s) and MDCTA of the abdomen and pelvis. Two independent readers assessed subjective image quality and the presence of arterial stenosis. Data were analysed on per-patient and per-segment bases. Fast MRA yielded better subjective image quality in all segments compared with conventional MRA (P = 0.012 for reader 1, P = 0.055 for reader 2) because of fewer motion-induced artefacts. Sensitivity and specificity of fast MRA for the detection of arterial stenosis were 100% for both readers. Sensitivity of conventional MRA was 89% for both readers, and specificity was 100% (reader 1) and 99% (reader 2). Differences in sensitivity between the two types of MRA were not significant for either reader. Interobserver agreement for the detection of arterial stenosis was excellent for fast (kappa = 1.00) and good for conventional MRA (kappa = 0.76). Thus, subjective image quality of visceral arteries remains good on fast MRA compared with conventional MRA, and the two techniques do not differ substantially in the grading of arterial stenosis, despite the markedly reduced acquisition time of fast MRA. [ABSTRACT FROM AUTHOR] |
| Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
|
Full text is not displayed to guests.
Login for full access.
|
|
| FullText | Links: – Type: pdflink Text: Availability: 1 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 105230780 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: MR angiography with parallel acquisition for assessment of the visceral arteries: comparison with conventional MR angiography and 64-detector-row computed tomography. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Sutter+R%22">Sutter R</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Heilmaier+C%22">Heilmaier C</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Lutz+AM%22">Lutz AM</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Weishaupt+D%22">Weishaupt D</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Seifert+B%22">Seifert B</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Willmann+JK%22">Willmann JK</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Sutter%2C+Reto%22">Sutter, Reto</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Heilmaier%2C+Christina%22">Heilmaier, Christina</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Lutz%2C+Amelie+M%22">Lutz, Amelie M</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Weishaupt%2C+Dominik%22">Weishaupt, Dominik</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Seifert%2C+Burkhardt%22">Seifert, Burkhardt</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Willmann%2C+Jürgen+K%22">Willmann, Jürgen K</searchLink> (AUTHOR) – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22European+Radiology%22">European Radiology</searchLink>. Nov2009, Vol. 19 Issue 11, p2679-2688. 10p. – Name: Abstract Label: Abstract Group: Ab Data: The purpose of the study was to retrospectively compare three-dimensional gadolinium-enhanced magnetic resonance angiography (conventional MRA) with MRA accelerated by a parallel acquisition technique (fast MRA) for the assessment of visceral arteries, using 64-detector-row computed tomography angiography (MDCTA) as the reference standard. Eighteen patients underwent fast MRA (imaging time 17 s), conventional MRA (29 s) and MDCTA of the abdomen and pelvis. Two independent readers assessed subjective image quality and the presence of arterial stenosis. Data were analysed on per-patient and per-segment bases. Fast MRA yielded better subjective image quality in all segments compared with conventional MRA (P = 0.012 for reader 1, P = 0.055 for reader 2) because of fewer motion-induced artefacts. Sensitivity and specificity of fast MRA for the detection of arterial stenosis were 100% for both readers. Sensitivity of conventional MRA was 89% for both readers, and specificity was 100% (reader 1) and 99% (reader 2). Differences in sensitivity between the two types of MRA were not significant for either reader. Interobserver agreement for the detection of arterial stenosis was excellent for fast (kappa = 1.00) and good for conventional MRA (kappa = 0.76). Thus, subjective image quality of visceral arteries remains good on fast MRA compared with conventional MRA, and the two techniques do not differ substantially in the grading of arterial stenosis, despite the markedly reduced acquisition time of fast MRA. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=105230780 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1007/s00330-009-1473-8 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 10 StartPage: 2679 Titles: – TitleFull: MR angiography with parallel acquisition for assessment of the visceral arteries: comparison with conventional MR angiography and 64-detector-row computed tomography. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Sutter R – PersonEntity: Name: NameFull: Heilmaier C – PersonEntity: Name: NameFull: Lutz AM – PersonEntity: Name: NameFull: Weishaupt D – PersonEntity: Name: NameFull: Seifert B – PersonEntity: Name: NameFull: Willmann JK – PersonEntity: Name: NameFull: Sutter, Reto – PersonEntity: Name: NameFull: Heilmaier, Christina – PersonEntity: Name: NameFull: Lutz, Amelie M – PersonEntity: Name: NameFull: Weishaupt, Dominik – PersonEntity: Name: NameFull: Seifert, Burkhardt – PersonEntity: Name: NameFull: Willmann, Jürgen K IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 11 Text: Nov2009 Type: published Y: 2009 Identifiers: – Type: issn-print Value: 09387994 Numbering: – Type: volume Value: 19 – Type: issue Value: 11 Titles: – TitleFull: European Radiology Type: main |
| ResultId | 1 |