Low-dose helical computed tomography (CT) in the perioperative workup of adolescent idiopathic scoliosis.

Saved in:
Bibliographic Details
Title: Low-dose helical computed tomography (CT) in the perioperative workup of adolescent idiopathic scoliosis.
Authors: Abul-Kasim K (AUTHOR), Overgaard A (AUTHOR), Maly P (AUTHOR), Ohlin A (AUTHOR), Gunnarsson M (AUTHOR), Sundgren PC (AUTHOR), Abul-Kasim, Kasim1 (AUTHOR), Overgaard, Angelica (AUTHOR), Maly, Pavel (AUTHOR), Ohlin, Acke (AUTHOR), Gunnarsson, Mikael (AUTHOR), Sundgren, Pia C (AUTHOR)
Source: European Radiology. Mar2009, Vol. 19 Issue 3, p610-618. 9p.
Abstract: The study aims were to estimate the radiation dose in patients examined with low dose spine CT and to compare it with that received by patients undergoing standard CT for trauma of the same region, as well as to evaluate the impact of dose reduction on image quality. Radiation doses in 113 consecutive low dose spine CTs were compared with those in 127 CTs for trauma. The inter- and intraobserver agreement in measurements of pedicular width, and vertebral rotation, measurements of signal-to-noise ratio and assessment of hardware status were the indicators in the evaluation of image quality. The effective dose of the low dose spine CT (0.37 mSv) was 20 times lower than that of a standard CT for trauma (13.09 mSv). This dose reduction conveyed no impact on image quality. This low dose spine CT protocol allows detailed evaluation that is necessary for preoperative planning and postoperative evaluation. [ABSTRACT FROM AUTHOR]
Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
Description
Abstract:The study aims were to estimate the radiation dose in patients examined with low dose spine CT and to compare it with that received by patients undergoing standard CT for trauma of the same region, as well as to evaluate the impact of dose reduction on image quality. Radiation doses in 113 consecutive low dose spine CTs were compared with those in 127 CTs for trauma. The inter- and intraobserver agreement in measurements of pedicular width, and vertebral rotation, measurements of signal-to-noise ratio and assessment of hardware status were the indicators in the evaluation of image quality. The effective dose of the low dose spine CT (0.37 mSv) was 20 times lower than that of a standard CT for trauma (13.09 mSv). This dose reduction conveyed no impact on image quality. This low dose spine CT protocol allows detailed evaluation that is necessary for preoperative planning and postoperative evaluation. [ABSTRACT FROM AUTHOR]
ISSN:09387994