Usefulness of multifunctional gastrointestinal coil catheter for colorectal stent placement.

Saved in:
Bibliographic Details
Title: Usefulness of multifunctional gastrointestinal coil catheter for colorectal stent placement.
Authors: Kim TH (AUTHOR), Song HY (AUTHOR), Shin JH (AUTHOR), Park IK (AUTHOR), Kim JH (AUTHOR), Lim JO (AUTHOR), Kim KR (AUTHOR), Choi EK (AUTHOR), Kim, Tae-Hyung1 (AUTHOR), Song, Ho-Young (AUTHOR), Shin, Ji Hoon (AUTHOR), Park, In Kook (AUTHOR), Kim, Jin Hyoung (AUTHOR), Lim, Jin-Oh (AUTHOR), Kim, Kyung Rae (AUTHOR), Choi, Eugene K (AUTHOR)
Source: European Radiology. Nov2008, Vol. 18 Issue 11, p2530-2534. 5p.
Abstract: The purpose of this study was to evaluate the usefulness of a multifunctional gastrointestinal coil catheter for stent placement in 98 patients with colorectal strictures. The catheter was used in 98 consecutive patients for stent placement in the rectum (n = 24), recto-sigmoid (n = 13), sigmoid (n = 38), descending (n = 6), transverse (n = 11), splenic flexure (n = 3), hepatic flexure (n = 2), and ascending (n = 1) colon. The catheter was made of a stainless steel coil (1.3 mm in inner diameter), a 0.4-mm nitinol wire, a polyolefin tube, and a hemostasis valve. Usefulness of the catheter was evaluated depending on whether the catheter could pass a stricture over a guide wire and whether measurement of the stricture length was possible. The passage of the catheter over a guide wire beyond the stricture was technically successful and well tolerated in 93 (94.9%) of 98 patients. In the failed five patients, it was not possible to negotiate the guide wire due to presence of nearly complete small bowel obstruction. The average length of stricture was 6.15 cm (range, 3 cm to 20 cm) in patients with the colorectal stricture. There were no procedure-related complications. In conclusion, the multifunctional coil catheter seems to be useful in colorectal stent placement. [ABSTRACT FROM AUTHOR]
Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
Description
Abstract:The purpose of this study was to evaluate the usefulness of a multifunctional gastrointestinal coil catheter for stent placement in 98 patients with colorectal strictures. The catheter was used in 98 consecutive patients for stent placement in the rectum (n = 24), recto-sigmoid (n = 13), sigmoid (n = 38), descending (n = 6), transverse (n = 11), splenic flexure (n = 3), hepatic flexure (n = 2), and ascending (n = 1) colon. The catheter was made of a stainless steel coil (1.3 mm in inner diameter), a 0.4-mm nitinol wire, a polyolefin tube, and a hemostasis valve. Usefulness of the catheter was evaluated depending on whether the catheter could pass a stricture over a guide wire and whether measurement of the stricture length was possible. The passage of the catheter over a guide wire beyond the stricture was technically successful and well tolerated in 93 (94.9%) of 98 patients. In the failed five patients, it was not possible to negotiate the guide wire due to presence of nearly complete small bowel obstruction. The average length of stricture was 6.15 cm (range, 3 cm to 20 cm) in patients with the colorectal stricture. There were no procedure-related complications. In conclusion, the multifunctional coil catheter seems to be useful in colorectal stent placement. [ABSTRACT FROM AUTHOR]
ISSN:09387994
DOI:10.1007/s00330-008-1042-6