Usefulness of multifunctional gastrointestinal coil catheter for colorectal stent placement.

Saved in:
Bibliographic Details
Title: Usefulness of multifunctional gastrointestinal coil catheter for colorectal stent placement.
Authors: Kim TH (AUTHOR), Song HY (AUTHOR), Shin JH (AUTHOR), Park IK (AUTHOR), Kim JH (AUTHOR), Lim JO (AUTHOR), Kim KR (AUTHOR), Choi EK (AUTHOR), Kim, Tae-Hyung1 (AUTHOR), Song, Ho-Young (AUTHOR), Shin, Ji Hoon (AUTHOR), Park, In Kook (AUTHOR), Kim, Jin Hyoung (AUTHOR), Lim, Jin-Oh (AUTHOR), Kim, Kyung Rae (AUTHOR), Choi, Eugene K (AUTHOR)
Source: European Radiology. Nov2008, Vol. 18 Issue 11, p2530-2534. 5p.
Abstract: The purpose of this study was to evaluate the usefulness of a multifunctional gastrointestinal coil catheter for stent placement in 98 patients with colorectal strictures. The catheter was used in 98 consecutive patients for stent placement in the rectum (n = 24), recto-sigmoid (n = 13), sigmoid (n = 38), descending (n = 6), transverse (n = 11), splenic flexure (n = 3), hepatic flexure (n = 2), and ascending (n = 1) colon. The catheter was made of a stainless steel coil (1.3 mm in inner diameter), a 0.4-mm nitinol wire, a polyolefin tube, and a hemostasis valve. Usefulness of the catheter was evaluated depending on whether the catheter could pass a stricture over a guide wire and whether measurement of the stricture length was possible. The passage of the catheter over a guide wire beyond the stricture was technically successful and well tolerated in 93 (94.9%) of 98 patients. In the failed five patients, it was not possible to negotiate the guide wire due to presence of nearly complete small bowel obstruction. The average length of stricture was 6.15 cm (range, 3 cm to 20 cm) in patients with the colorectal stricture. There were no procedure-related complications. In conclusion, the multifunctional coil catheter seems to be useful in colorectal stent placement. [ABSTRACT FROM AUTHOR]
Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: egs
DbLabel: Engineering Source
An: 105617864
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Usefulness of multifunctional gastrointestinal coil catheter for colorectal stent placement.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Kim+TH%22">Kim TH</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Song+HY%22">Song HY</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Shin+JH%22">Shin JH</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Park+IK%22">Park IK</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Kim+JH%22">Kim JH</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Lim+JO%22">Lim JO</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Kim+KR%22">Kim KR</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Choi+EK%22">Choi EK</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Kim%2C+Tae-Hyung%22">Kim, Tae-Hyung</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Song%2C+Ho-Young%22">Song, Ho-Young</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Shin%2C+Ji+Hoon%22">Shin, Ji Hoon</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Park%2C+In+Kook%22">Park, In Kook</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Kim%2C+Jin+Hyoung%22">Kim, Jin Hyoung</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Lim%2C+Jin-Oh%22">Lim, Jin-Oh</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Kim%2C+Kyung+Rae%22">Kim, Kyung Rae</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Choi%2C+Eugene+K%22">Choi, Eugene K</searchLink> (AUTHOR)
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22European+Radiology%22">European Radiology</searchLink>. Nov2008, Vol. 18 Issue 11, p2530-2534. 5p.
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: The purpose of this study was to evaluate the usefulness of a multifunctional gastrointestinal coil catheter for stent placement in 98 patients with colorectal strictures. The catheter was used in 98 consecutive patients for stent placement in the rectum (n = 24), recto-sigmoid (n = 13), sigmoid (n = 38), descending (n = 6), transverse (n = 11), splenic flexure (n = 3), hepatic flexure (n = 2), and ascending (n = 1) colon. The catheter was made of a stainless steel coil (1.3 mm in inner diameter), a 0.4-mm nitinol wire, a polyolefin tube, and a hemostasis valve. Usefulness of the catheter was evaluated depending on whether the catheter could pass a stricture over a guide wire and whether measurement of the stricture length was possible. The passage of the catheter over a guide wire beyond the stricture was technically successful and well tolerated in 93 (94.9%) of 98 patients. In the failed five patients, it was not possible to negotiate the guide wire due to presence of nearly complete small bowel obstruction. The average length of stricture was 6.15 cm (range, 3 cm to 20 cm) in patients with the colorectal stricture. There were no procedure-related complications. In conclusion, the multifunctional coil catheter seems to be useful in colorectal stent placement. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=105617864
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1007/s00330-008-1042-6
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 5
        StartPage: 2530
    Titles:
      – TitleFull: Usefulness of multifunctional gastrointestinal coil catheter for colorectal stent placement.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Kim TH
      – PersonEntity:
          Name:
            NameFull: Song HY
      – PersonEntity:
          Name:
            NameFull: Shin JH
      – PersonEntity:
          Name:
            NameFull: Park IK
      – PersonEntity:
          Name:
            NameFull: Kim JH
      – PersonEntity:
          Name:
            NameFull: Lim JO
      – PersonEntity:
          Name:
            NameFull: Kim KR
      – PersonEntity:
          Name:
            NameFull: Choi EK
      – PersonEntity:
          Name:
            NameFull: Kim, Tae-Hyung
      – PersonEntity:
          Name:
            NameFull: Song, Ho-Young
      – PersonEntity:
          Name:
            NameFull: Shin, Ji Hoon
      – PersonEntity:
          Name:
            NameFull: Park, In Kook
      – PersonEntity:
          Name:
            NameFull: Kim, Jin Hyoung
      – PersonEntity:
          Name:
            NameFull: Lim, Jin-Oh
      – PersonEntity:
          Name:
            NameFull: Kim, Kyung Rae
      – PersonEntity:
          Name:
            NameFull: Choi, Eugene K
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 11
              Text: Nov2008
              Type: published
              Y: 2008
          Identifiers:
            – Type: issn-print
              Value: 09387994
          Numbering:
            – Type: volume
              Value: 18
            – Type: issue
              Value: 11
          Titles:
            – TitleFull: European Radiology
              Type: main
ResultId 1