Alteration of the amount and morphology of wear particles by the addition of loading profile transitions during artificial hip wear testing.

Saved in:
Bibliographic Details
Title: Alteration of the amount and morphology of wear particles by the addition of loading profile transitions during artificial hip wear testing.
Authors: Shorez JP (AUTHOR), Harding TS (AUTHOR), Atkinson PJ (AUTHOR), Walter N (AUTHOR), Shorez, J P1 (AUTHOR), Harding, T S (AUTHOR), Atkinson, P J (AUTHOR), Walter, N (AUTHOR)
Source: Proceedings of the Institution of Mechanical Engineers -- Part H -- Journal of Engineering in Medicine (Professional Engineering Publishing). Aug2008, Vol. 222 Issue 6, p865-875. 11p.
Abstract: Current validation tests of total hip arthroplasty endo-prostheses capture only a single activity performed by patients: continuous walking. A more representative test that includes transitions from a static loaded position to dynamic motion would simulate common motions by patients in which they change from standing to walking. The introduction of such transitions into a traditional test protocol could provide insight into actual wear behaviours and more realistic wear particle properties such as size and shape. First, the introduction of transitions will increase the measured wear rate. Second, the amount of wear will be positively correlated to the number of transitions per day. Finally, the size and shape of polyethylene particle produced via testing with transitions will differ from those of a conventional continuous walking test. Three identical sets of four cobalt chromium femoral heads and sterilized acetabular cups sterilized in ethylene oxide were tested in 30 per cent bovine serum under three conditions: continuous walking (0 transitions/day), 10 transitions/day, and 100 transitions/day. A day was defined as 2500 steps. The static and peak dynamic loads were 260 N and 1.9 kN respectively. A testing duration of 106 cycles was completed for each of the three tests. The wear rate was found to be inversely related to the number of transitions. Particle analysis showed that the particle size decreased as the number of transitions increased. Particles from the 100 transitions/day test were more fibular and produced more particles of the size known to promote an immune reactive response. Contrary to our hypothesis, as the number of transitions performed by patients increased, the wear rate and accumulated wear decreased. In addition, as the number of transitions increased, a larger percentage of wear particles were in the submicron size range. Consequently, despite a decrease in wear due to the presence of loading profile transitions, there is a potentially greater risk of osteolysis owing to the increased production of immunoreactive particles. [ABSTRACT FROM AUTHOR]
Copyright of Proceedings of the Institution of Mechanical Engineers -- Part H -- Journal of Engineering in Medicine (Professional Engineering Publishing) is the property of Professional Engineering Publishing and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 105627424
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Alteration of the amount and morphology of wear particles by the addition of loading profile transitions during artificial hip wear testing.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Shorez+JP%22">Shorez JP</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Harding+TS%22">Harding TS</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Atkinson+PJ%22">Atkinson PJ</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Walter+N%22">Walter N</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Shorez%2C+J+P%22">Shorez, J P</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Harding%2C+T+S%22">Harding, T S</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Atkinson%2C+P+J%22">Atkinson, P J</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Walter%2C+N%22">Walter, N</searchLink> (AUTHOR)
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Proceedings+of+the+Institution+of+Mechanical+Engineers+--+Part+H+--+Journal+of+Engineering+in+Medicine+%28Professional+Engineering+Publishing%29%22">Proceedings of the Institution of Mechanical Engineers -- Part H -- Journal of Engineering in Medicine (Professional Engineering Publishing)</searchLink>. Aug2008, Vol. 222 Issue 6, p865-875. 11p.
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Current validation tests of total hip arthroplasty endo-prostheses capture only a single activity performed by patients: continuous walking. A more representative test that includes transitions from a static loaded position to dynamic motion would simulate common motions by patients in which they change from standing to walking. The introduction of such transitions into a traditional test protocol could provide insight into actual wear behaviours and more realistic wear particle properties such as size and shape. First, the introduction of transitions will increase the measured wear rate. Second, the amount of wear will be positively correlated to the number of transitions per day. Finally, the size and shape of polyethylene particle produced via testing with transitions will differ from those of a conventional continuous walking test. Three identical sets of four cobalt chromium femoral heads and sterilized acetabular cups sterilized in ethylene oxide were tested in 30 per cent bovine serum under three conditions: continuous walking (0 transitions/day), 10 transitions/day, and 100 transitions/day. A day was defined as 2500 steps. The static and peak dynamic loads were 260 N and 1.9 kN respectively. A testing duration of 106 cycles was completed for each of the three tests. The wear rate was found to be inversely related to the number of transitions. Particle analysis showed that the particle size decreased as the number of transitions increased. Particles from the 100 transitions/day test were more fibular and produced more particles of the size known to promote an immune reactive response. Contrary to our hypothesis, as the number of transitions performed by patients increased, the wear rate and accumulated wear decreased. In addition, as the number of transitions increased, a larger percentage of wear particles were in the submicron size range. Consequently, despite a decrease in wear due to the presence of loading profile transitions, there is a potentially greater risk of osteolysis owing to the increased production of immunoreactive particles. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Proceedings of the Institution of Mechanical Engineers -- Part H -- Journal of Engineering in Medicine (Professional Engineering Publishing) is the property of Professional Engineering Publishing and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=105627424
RecordInfo BibRecord:
  BibEntity:
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 11
        StartPage: 865
    Titles:
      – TitleFull: Alteration of the amount and morphology of wear particles by the addition of loading profile transitions during artificial hip wear testing.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Shorez JP
      – PersonEntity:
          Name:
            NameFull: Harding TS
      – PersonEntity:
          Name:
            NameFull: Atkinson PJ
      – PersonEntity:
          Name:
            NameFull: Walter N
      – PersonEntity:
          Name:
            NameFull: Shorez, J P
      – PersonEntity:
          Name:
            NameFull: Harding, T S
      – PersonEntity:
          Name:
            NameFull: Atkinson, P J
      – PersonEntity:
          Name:
            NameFull: Walter, N
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 08
              Text: Aug2008
              Type: published
              Y: 2008
          Identifiers:
            – Type: issn-print
              Value: 09544119
          Numbering:
            – Type: volume
              Value: 222
            – Type: issue
              Value: 6
          Titles:
            – TitleFull: Proceedings of the Institution of Mechanical Engineers -- Part H -- Journal of Engineering in Medicine (Professional Engineering Publishing)
              Type: main
ResultId 1