Assessment of an Advanced Monoenergetic Reconstruction Technique in Dual-Energy Computed Tomography of Head and Neck Cancer.
Saved in:
| Title: | Assessment of an Advanced Monoenergetic Reconstruction Technique in Dual-Energy Computed Tomography of Head and Neck Cancer. |
|---|---|
| Authors: | Albrecht, Moritz H (AUTHOR), Scholtz, Jan-Erik (AUTHOR), Kraft, Johannes (AUTHOR), Bauer, Ralf W (AUTHOR), Kaup, Moritz (AUTHOR), Dewes, Patricia (AUTHOR), Bucher, Andreas M (AUTHOR), Burck, Iris (AUTHOR), Wagenblast, Jens (AUTHOR), Lehnert, Thomas (AUTHOR), Kerl, J Matthias (AUTHOR), Vogl, Thomas J (AUTHOR), Wichmann, Julian L (AUTHOR) |
| Source: | European Radiology. Aug2015, Vol. 25 Issue 8, p2493-2501. 9p. |
| Abstract: | |
| Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
|
Full text is not displayed to guests.
Login for full access.
|
|
| FullText | Links: – Type: pdflink Text: Availability: 1 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 109594938 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Assessment of an Advanced Monoenergetic Reconstruction Technique in Dual-Energy Computed Tomography of Head and Neck Cancer. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Albrecht%2C+Moritz+H%22">Albrecht, Moritz H</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Scholtz%2C+Jan-Erik%22">Scholtz, Jan-Erik</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Kraft%2C+Johannes%22">Kraft, Johannes</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Bauer%2C+Ralf+W%22">Bauer, Ralf W</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Kaup%2C+Moritz%22">Kaup, Moritz</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Dewes%2C+Patricia%22">Dewes, Patricia</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Bucher%2C+Andreas+M%22">Bucher, Andreas M</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Burck%2C+Iris%22">Burck, Iris</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Wagenblast%2C+Jens%22">Wagenblast, Jens</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Lehnert%2C+Thomas%22">Lehnert, Thomas</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Kerl%2C+J+Matthias%22">Kerl, J Matthias</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Vogl%2C+Thomas+J%22">Vogl, Thomas J</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Wichmann%2C+Julian+L%22">Wichmann, Julian L</searchLink> (AUTHOR) – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22European+Radiology%22">European Radiology</searchLink>. Aug2015, Vol. 25 Issue 8, p2493-2501. 9p. – Name: Abstract Label: Abstract Group: Ab Data: <bold>Objectives: </bold>To define optimal keV settings for advanced monoenergetic (Mono+) dual-energy computed tomography (DECT) in patients with head and neck squamous cell carcinoma (SCC).<bold>Methods: </bold>DECT data of 44 patients (34 men, mean age 55.5 ± 16.0 years) with histopathologically confirmed SCC were reconstructed as 40, 55, 70 keV Mono + and M_0.3 (30 % 80 kV) linearly blended series. Attenuation of tumour, sternocleidomastoid muscle, internal jugular vein, submandibular gland, and noise were measured. Three radiologists with >3 years of experience subjectively assessed image quality, lesion delineation, image sharpness, and noise.<bold>Results: </bold>The highest lesion attenuation was shown for 40 keV series (248.1 ± 94.1 HU), followed by 55 keV (150.2 ± 55.5 HU; P = 0.001). Contrast-to-noise ratio (CNR) at 40 keV (19.09 ± 13.84) was significantly superior to all other reconstructions (55 keV, 10.25 ± 9.11; 70 keV, 7.68 ± 6.31; M_0.3, 5.49 ± 3.28; all P < 0.005). Subjective image quality was highest for 55 keV images (4.53; κ = 0.38, P = 0.003), followed by 40 keV (4.14; κ = 0.43, P < 0.001) and 70 keV reconstructions (4.06; κ = 0.32, P = 0.005), all superior (P < 0.004) to linear blending M_0.3 (3.81; κ = 0.280, P = 0.056).<bold>Conclusions: </bold>Mono + DECT at low keV levels significantly improves CNR and subjective image quality in patients with head and neck SCC, as tumour CNR peaks at 40 keV, and 55 keV images are preferred by observers.<bold>Key Points: </bold>• Mono + DECT combines increased contrast with reduced image noise, unlike linearly blended images. • Mono + DECT imaging allows for superior CNR and subjective image quality. • Head and neck tumour contrast-to-noise ratio peaks at 40 keV. • 55 keV images are preferred over all other series by observers. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=109594938 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1007/s00330-015-3627-1 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 9 StartPage: 2493 Titles: – TitleFull: Assessment of an Advanced Monoenergetic Reconstruction Technique in Dual-Energy Computed Tomography of Head and Neck Cancer. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Albrecht, Moritz H – PersonEntity: Name: NameFull: Scholtz, Jan-Erik – PersonEntity: Name: NameFull: Kraft, Johannes – PersonEntity: Name: NameFull: Bauer, Ralf W – PersonEntity: Name: NameFull: Kaup, Moritz – PersonEntity: Name: NameFull: Dewes, Patricia – PersonEntity: Name: NameFull: Bucher, Andreas M – PersonEntity: Name: NameFull: Burck, Iris – PersonEntity: Name: NameFull: Wagenblast, Jens – PersonEntity: Name: NameFull: Lehnert, Thomas – PersonEntity: Name: NameFull: Kerl, J Matthias – PersonEntity: Name: NameFull: Vogl, Thomas J – PersonEntity: Name: NameFull: Wichmann, Julian L IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 08 Text: Aug2015 Type: published Y: 2015 Identifiers: – Type: issn-print Value: 09387994 Numbering: – Type: volume Value: 25 – Type: issue Value: 8 Titles: – TitleFull: European Radiology Type: main |
| ResultId | 1 |