Influence of nuclear interactions in body tissues on tumor dose in carbon-ion radiotherapy.
Saved in:
| Title: | Influence of nuclear interactions in body tissues on tumor dose in carbon-ion radiotherapy. |
|---|---|
| Authors: | Inaniwa, T.1, Kanematsu, N.1, Tsuji, H.2, Kamada, T.2 |
| Source: | Medical Physics. Dec2015, Vol. 42 Issue 12, p7132-7137. 6p. |
| Subjects: | Head & neck cancer diagnosis, Head & neck cancer treatment, Cancer radiotherapy, Radiation doses, Carbon, Medical errors |
| Abstract: | Purpose: In carbon-ion radiotherapy treatment planning, the planar integrated dose (PID) measured in water is applied to the patient dose calculation with density scaling using the stopping power ratio. Since body tissues are chemically different from water, this dose calculation can be subject to errors, particularly due to differences in inelastic nuclear interactions. In recent studies, the authors proposed and validated a PID correction method for these errors. In the present study, the authors used this correction method to assess the influence of these nuclear interactions in body tissues on tumor dose in various clinical cases. Methods: Using 10-20 cases each of prostate, head and neck (HN), bone and soft tissue (BS), lung, liver, pancreas, and uterine neoplasms, the authors first used treatment plans for carbon-ion radiotherapy without nuclear interaction correction to derive uncorrected dose distributions. The authors then compared these distributions with recalculated distributions using the nuclear interaction correction (corrected dose distributions). Results: Median (25%/75% quartiles) differences between the target mean uncorrected doses and corrected doses were 0.2% (0.1%/0.2%), 0.0% (0.0%/0.0%), -0.3% (-0.4%/-0.2%), -0.1% (-0.2%/-0.1%), -0.1% (-0.2%/0.0%), -0.4% (-0.5%/-0.1%), and -0.3% (-0.4%/0.0%) for the prostate, HN, BS, lung, liver, pancreas, and uterine cases, respectively. The largest difference of -1.6% in target mean and -2.5% at maximum were observed in a uterine case. Conclusions: For most clinical cases, dose calculation errors due to the water nonequivalence of the tissues in nuclear interactions would be marginal compared to intrinsic uncertainties in treatment planning, patient setup, beam delivery, and clinical response. In some extreme cases, however, these errors can be substantial. Accordingly, this correction method should be routinely applied to treatment planning in clinical practice. [ABSTRACT FROM AUTHOR] |
| Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
|
Full text is not displayed to guests.
Login for full access.
|
|
| FullText | Links: – Type: pdflink Text: Availability: 1 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 111402350 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Influence of nuclear interactions in body tissues on tumor dose in carbon-ion radiotherapy. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Inaniwa%2C+T%2E%22">Inaniwa, T.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Kanematsu%2C+N%2E%22">Kanematsu, N.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Tsuji%2C+H%2E%22">Tsuji, H.</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Kamada%2C+T%2E%22">Kamada, T.</searchLink><relatesTo>2</relatesTo> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Medical+Physics%22">Medical Physics</searchLink>. Dec2015, Vol. 42 Issue 12, p7132-7137. 6p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Head+%26+neck+cancer+diagnosis%22">Head & neck cancer diagnosis</searchLink><br /><searchLink fieldCode="DE" term="%22Head+%26+neck+cancer+treatment%22">Head & neck cancer treatment</searchLink><br /><searchLink fieldCode="DE" term="%22Cancer+radiotherapy%22">Cancer radiotherapy</searchLink><br /><searchLink fieldCode="DE" term="%22Radiation+doses%22">Radiation doses</searchLink><br /><searchLink fieldCode="DE" term="%22Carbon%22">Carbon</searchLink><br /><searchLink fieldCode="DE" term="%22Medical+errors%22">Medical errors</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: Purpose: In carbon-ion radiotherapy treatment planning, the planar integrated dose (PID) measured in water is applied to the patient dose calculation with density scaling using the stopping power ratio. Since body tissues are chemically different from water, this dose calculation can be subject to errors, particularly due to differences in inelastic nuclear interactions. In recent studies, the authors proposed and validated a PID correction method for these errors. In the present study, the authors used this correction method to assess the influence of these nuclear interactions in body tissues on tumor dose in various clinical cases. Methods: Using 10-20 cases each of prostate, head and neck (HN), bone and soft tissue (BS), lung, liver, pancreas, and uterine neoplasms, the authors first used treatment plans for carbon-ion radiotherapy without nuclear interaction correction to derive uncorrected dose distributions. The authors then compared these distributions with recalculated distributions using the nuclear interaction correction (corrected dose distributions). Results: Median (25%/75% quartiles) differences between the target mean uncorrected doses and corrected doses were 0.2% (0.1%/0.2%), 0.0% (0.0%/0.0%), -0.3% (-0.4%/-0.2%), -0.1% (-0.2%/-0.1%), -0.1% (-0.2%/0.0%), -0.4% (-0.5%/-0.1%), and -0.3% (-0.4%/0.0%) for the prostate, HN, BS, lung, liver, pancreas, and uterine cases, respectively. The largest difference of -1.6% in target mean and -2.5% at maximum were observed in a uterine case. Conclusions: For most clinical cases, dose calculation errors due to the water nonequivalence of the tissues in nuclear interactions would be marginal compared to intrinsic uncertainties in treatment planning, patient setup, beam delivery, and clinical response. In some extreme cases, however, these errors can be substantial. Accordingly, this correction method should be routinely applied to treatment planning in clinical practice. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=111402350 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1118/1.4936105 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 6 StartPage: 7132 Subjects: – SubjectFull: Head & neck cancer diagnosis Type: general – SubjectFull: Head & neck cancer treatment Type: general – SubjectFull: Cancer radiotherapy Type: general – SubjectFull: Radiation doses Type: general – SubjectFull: Carbon Type: general – SubjectFull: Medical errors Type: general Titles: – TitleFull: Influence of nuclear interactions in body tissues on tumor dose in carbon-ion radiotherapy. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Inaniwa, T. – PersonEntity: Name: NameFull: Kanematsu, N. – PersonEntity: Name: NameFull: Tsuji, H. – PersonEntity: Name: NameFull: Kamada, T. IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 12 Text: Dec2015 Type: published Y: 2015 Identifiers: – Type: issn-print Value: 00942405 Numbering: – Type: volume Value: 42 – Type: issue Value: 12 Titles: – TitleFull: Medical Physics Type: main |
| ResultId | 1 |