Optical phantoms with adjustable subdiffusive scattering parameters.
Saved in:
| Title: | Optical phantoms with adjustable subdiffusive scattering parameters. |
|---|---|
| Authors: | Krauter, Philipp1 philipp.krauter@ilm-ulm.de, Nothelfer, Steffen1, Bodenschatz, Nico1, Simon, Emanuel1, Stocker, Sabrina1, Foschum, Florian Foschum1, Kienle, Alwin1 |
| Source: | Journal of Biomedical Optics. Oct2015, Vol. 20 Issue 10, p105008-1-105008-10. 10p. |
| Subjects: | Imaging phantoms, Scattering potentials, Intrinsic factor (Physiology), Fluorescence, Refractive index |
| Abstract: | A new epoxy-resin-based optical phantom system with adjustable subdiffusive scattering parameters is presented along with measurements of the intrinsic absorption, scattering, fluorescence, and refractive index of the matrix material. Both an aluminium oxide powder and a titanium dioxide dispersion were used as scattering agents and we present measurements of their scattering and reduced scattering coefficients. A method is theoretically described for a mixture of both scattering agents to obtain continuously adjustable anisotropy values g between 0.65 and 0.9 and values of the phase function parameter γ in the range of 1.4 to 2.2. Furthermore, we show absorption spectra for a set of pigments that can be added to achieve particular absorption characteristics. By additional analysis of the aging, a fully characterized phantom system is obtained with the novelty of g and γ parameter adjustment. [ABSTRACT FROM AUTHOR] |
| Copyright of Journal of Biomedical Optics is the property of SPIE - International Society of Optical Engineering and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
| FullText | Text: Availability: 0 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 111431264 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Optical phantoms with adjustable subdiffusive scattering parameters. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Krauter%2C+Philipp%22">Krauter, Philipp</searchLink><relatesTo>1</relatesTo><i> philipp.krauter@ilm-ulm.de</i><br /><searchLink fieldCode="AR" term="%22Nothelfer%2C+Steffen%22">Nothelfer, Steffen</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Bodenschatz%2C+Nico%22">Bodenschatz, Nico</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Simon%2C+Emanuel%22">Simon, Emanuel</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Stocker%2C+Sabrina%22">Stocker, Sabrina</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Foschum%2C+Florian+Foschum%22">Foschum, Florian Foschum</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Kienle%2C+Alwin%22">Kienle, Alwin</searchLink><relatesTo>1</relatesTo> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Journal+of+Biomedical+Optics%22">Journal of Biomedical Optics</searchLink>. Oct2015, Vol. 20 Issue 10, p105008-1-105008-10. 10p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Imaging+phantoms%22">Imaging phantoms</searchLink><br /><searchLink fieldCode="DE" term="%22Scattering+potentials%22">Scattering potentials</searchLink><br /><searchLink fieldCode="DE" term="%22Intrinsic+factor+%28Physiology%29%22">Intrinsic factor (Physiology)</searchLink><br /><searchLink fieldCode="DE" term="%22Fluorescence%22">Fluorescence</searchLink><br /><searchLink fieldCode="DE" term="%22Refractive+index%22">Refractive index</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: A new epoxy-resin-based optical phantom system with adjustable subdiffusive scattering parameters is presented along with measurements of the intrinsic absorption, scattering, fluorescence, and refractive index of the matrix material. Both an aluminium oxide powder and a titanium dioxide dispersion were used as scattering agents and we present measurements of their scattering and reduced scattering coefficients. A method is theoretically described for a mixture of both scattering agents to obtain continuously adjustable anisotropy values g between 0.65 and 0.9 and values of the phase function parameter γ in the range of 1.4 to 2.2. Furthermore, we show absorption spectra for a set of pigments that can be added to achieve particular absorption characteristics. By additional analysis of the aging, a fully characterized phantom system is obtained with the novelty of g and γ parameter adjustment. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Journal of Biomedical Optics is the property of SPIE - International Society of Optical Engineering and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=111431264 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1117/1.JBO.20.10.105008 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 10 StartPage: 105008-1 Subjects: – SubjectFull: Imaging phantoms Type: general – SubjectFull: Scattering potentials Type: general – SubjectFull: Intrinsic factor (Physiology) Type: general – SubjectFull: Fluorescence Type: general – SubjectFull: Refractive index Type: general Titles: – TitleFull: Optical phantoms with adjustable subdiffusive scattering parameters. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Krauter, Philipp – PersonEntity: Name: NameFull: Nothelfer, Steffen – PersonEntity: Name: NameFull: Bodenschatz, Nico – PersonEntity: Name: NameFull: Simon, Emanuel – PersonEntity: Name: NameFull: Stocker, Sabrina – PersonEntity: Name: NameFull: Foschum, Florian Foschum – PersonEntity: Name: NameFull: Kienle, Alwin IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 10 Text: Oct2015 Type: published Y: 2015 Identifiers: – Type: issn-print Value: 10833668 Numbering: – Type: volume Value: 20 – Type: issue Value: 10 Titles: – TitleFull: Journal of Biomedical Optics Type: main |
| ResultId | 1 |