Rigorous buoyancy driven bubble mixing for centrifugal microfluidics.

Saved in:
Bibliographic Details
Title: Rigorous buoyancy driven bubble mixing for centrifugal microfluidics.
Authors: Burger, S.1, Schulz, M.1, von Stetten, F.1,2, Zengerle, R.1,2,3, Paust, N.1,2
Source: Lab on a Chip. 1/21/2016, Vol. 16 Issue 2, p261-268. 8p.
Subjects: Microfluidics, Centrifugal force, Biological assay research, Bubbles, Labs on a chip
Abstract: We present batch-mode mixing for centrifugal microfluidics operated at fixed rotational frequency. Gas is generated by the disk integrated decomposition of hydrogen peroxide (H2O2) to liquid water (H2O) and gaseous oxygen (O2) and inserted into a mixing chamber. There, bubbles are formed that ascent through the liquid in the artificial gravity field and lead to drag flow. Additionaly, strong buoyancy causes deformation and rupture of the gas bubbles and induces strong mixing flows in the liquids. Buoyancy driven bubble mixing is quantitatively compared to shake mode mixing, mixing by reciprocation and vortex mixing. To determine mixing efficiencies in a meaningful way, the different mixers are employed for mixing of a lysis reagent and human whole blood. Subsequently, DNA is extracted from the lysate and the amount of DNA recovered is taken as a measure for mixing efficiency. Relative to standard vortex mixing, DNA extraction based on buoyancy driven bubble mixing resulted in yields of 92 ± 8% (100 s mixing time) and 100 ± 8% (600 s) at 130g centrifugal acceleration. Shake mode mixing yields 96 ± 11% and is thus equal to buoyancy driven bubble mixing. An advantage of buoyancy driven bubble mixing is that it can be operated at fixed rotational frequency, however. The additional costs of implementing buoyancy driven bubble mixing are low since both the activation liquid and the catalyst are very low cost and no external means are required in the processing device. Furthermore, buoyancy driven bubble mixing can easily be integrated in a monolithic manner and is compatible to scalable manufacturing technologies such as injection moulding or thermoforming. We consider buoyancy driven bubble mixing an excellent alternative to shake mode mixing, in particular if the processing device is not capable of providing fast changes of rotational frequency or if the low average rotational frequency is challenging for the other integrated fluidic operations. [ABSTRACT FROM AUTHOR]
Copyright of Lab on a Chip is the property of Royal Society of Chemistry and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 112085861
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Rigorous buoyancy driven bubble mixing for centrifugal microfluidics.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Burger%2C+S%2E%22">Burger, S.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Schulz%2C+M%2E%22">Schulz, M.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22von+Stetten%2C+F%2E%22">von Stetten, F.</searchLink><relatesTo>1,2</relatesTo><br /><searchLink fieldCode="AR" term="%22Zengerle%2C+R%2E%22">Zengerle, R.</searchLink><relatesTo>1,2,3</relatesTo><br /><searchLink fieldCode="AR" term="%22Paust%2C+N%2E%22">Paust, N.</searchLink><relatesTo>1,2</relatesTo>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Lab+on+a+Chip%22">Lab on a Chip</searchLink>. 1/21/2016, Vol. 16 Issue 2, p261-268. 8p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Microfluidics%22">Microfluidics</searchLink><br /><searchLink fieldCode="DE" term="%22Centrifugal+force%22">Centrifugal force</searchLink><br /><searchLink fieldCode="DE" term="%22Biological+assay+research%22">Biological assay research</searchLink><br /><searchLink fieldCode="DE" term="%22Bubbles%22">Bubbles</searchLink><br /><searchLink fieldCode="DE" term="%22Labs+on+a+chip%22">Labs on a chip</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: We present batch-mode mixing for centrifugal microfluidics operated at fixed rotational frequency. Gas is generated by the disk integrated decomposition of hydrogen peroxide (H2O2) to liquid water (H2O) and gaseous oxygen (O2) and inserted into a mixing chamber. There, bubbles are formed that ascent through the liquid in the artificial gravity field and lead to drag flow. Additionaly, strong buoyancy causes deformation and rupture of the gas bubbles and induces strong mixing flows in the liquids. Buoyancy driven bubble mixing is quantitatively compared to shake mode mixing, mixing by reciprocation and vortex mixing. To determine mixing efficiencies in a meaningful way, the different mixers are employed for mixing of a lysis reagent and human whole blood. Subsequently, DNA is extracted from the lysate and the amount of DNA recovered is taken as a measure for mixing efficiency. Relative to standard vortex mixing, DNA extraction based on buoyancy driven bubble mixing resulted in yields of 92 ± 8% (100 s mixing time) and 100 ± 8% (600 s) at 130g centrifugal acceleration. Shake mode mixing yields 96 ± 11% and is thus equal to buoyancy driven bubble mixing. An advantage of buoyancy driven bubble mixing is that it can be operated at fixed rotational frequency, however. The additional costs of implementing buoyancy driven bubble mixing are low since both the activation liquid and the catalyst are very low cost and no external means are required in the processing device. Furthermore, buoyancy driven bubble mixing can easily be integrated in a monolithic manner and is compatible to scalable manufacturing technologies such as injection moulding or thermoforming. We consider buoyancy driven bubble mixing an excellent alternative to shake mode mixing, in particular if the processing device is not capable of providing fast changes of rotational frequency or if the low average rotational frequency is challenging for the other integrated fluidic operations. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Lab on a Chip is the property of Royal Society of Chemistry and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=112085861
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1039/c5lc01280e
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 8
        StartPage: 261
    Subjects:
      – SubjectFull: Microfluidics
        Type: general
      – SubjectFull: Centrifugal force
        Type: general
      – SubjectFull: Biological assay research
        Type: general
      – SubjectFull: Bubbles
        Type: general
      – SubjectFull: Labs on a chip
        Type: general
    Titles:
      – TitleFull: Rigorous buoyancy driven bubble mixing for centrifugal microfluidics.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Burger, S.
      – PersonEntity:
          Name:
            NameFull: Schulz, M.
      – PersonEntity:
          Name:
            NameFull: von Stetten, F.
      – PersonEntity:
          Name:
            NameFull: Zengerle, R.
      – PersonEntity:
          Name:
            NameFull: Paust, N.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 21
              M: 01
              Text: 1/21/2016
              Type: published
              Y: 2016
          Identifiers:
            – Type: issn-print
              Value: 14730197
          Numbering:
            – Type: volume
              Value: 16
            – Type: issue
              Value: 2
          Titles:
            – TitleFull: Lab on a Chip
              Type: main
ResultId 1