A monolithic 180 nm CMOS dosimeter for wireless In Vivo Dosimetry.
Saved in:
| Title: | A monolithic 180 nm CMOS dosimeter for wireless In Vivo Dosimetry. |
|---|---|
| Authors: | Villani, E.G.1 Giulio.villani@stfc.ac.uk, Crepaldi, M.2, DeMarchi, D.2, Gabrielli, A.3, Khan, A.4, Pikhay, E.5, Roizin, Y.5, Rosenfeld, A.6, Zhang, Z.1 |
| Source: | Radiation Measurements. Jan2016, Vol. 84, p55-64. 10p. |
| Subjects: | Complementary metal oxide semiconductors, Radiation dosimetry, Dosimeters, Systems on a chip, Radiotherapy, High resolution imaging |
| Abstract: | The design, fabrication and testing of a novel monolithic system-on-chip dosimeter fabricated in a standard 180 nm CMOS technology is described. The device, implementing a radiation sensor and an RF transmitter, is proposed to address the need for real-time In Vivo Dosimetry (IVD) of radiation during Linac radiotherapy sessions. Owing to its small size, of approximately 1 mm 3 , such solution could be made in-body implantable and, as such, provide a much-enhanced high-resolution, real-time dose measurement to improve Quality Assurance (QA) in radiation therapy. The device transmits the related information on dose of radiation wirelessly to a remote receiver operating in the Medical Implant Communication Service (MICS) band. Comprehensive description of the various phases of this project, including the development of the radiation sensors and integrated RF transmitter to perform the readout, along with the final test results using a radiation beam, will be given. [ABSTRACT FROM AUTHOR] |
| Copyright of Radiation Measurements is the property of Pergamon Press - An Imprint of Elsevier Science and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
| FullText | Text: Availability: 0 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 112264890 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: A monolithic 180 nm CMOS dosimeter for wireless In Vivo Dosimetry. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Villani%2C+E%2EG%2E%22">Villani, E.G.</searchLink><relatesTo>1</relatesTo><i> Giulio.villani@stfc.ac.uk</i><br /><searchLink fieldCode="AR" term="%22Crepaldi%2C+M%2E%22">Crepaldi, M.</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22DeMarchi%2C+D%2E%22">DeMarchi, D.</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Gabrielli%2C+A%2E%22">Gabrielli, A.</searchLink><relatesTo>3</relatesTo><br /><searchLink fieldCode="AR" term="%22Khan%2C+A%2E%22">Khan, A.</searchLink><relatesTo>4</relatesTo><br /><searchLink fieldCode="AR" term="%22Pikhay%2C+E%2E%22">Pikhay, E.</searchLink><relatesTo>5</relatesTo><br /><searchLink fieldCode="AR" term="%22Roizin%2C+Y%2E%22">Roizin, Y.</searchLink><relatesTo>5</relatesTo><br /><searchLink fieldCode="AR" term="%22Rosenfeld%2C+A%2E%22">Rosenfeld, A.</searchLink><relatesTo>6</relatesTo><br /><searchLink fieldCode="AR" term="%22Zhang%2C+Z%2E%22">Zhang, Z.</searchLink><relatesTo>1</relatesTo> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Radiation+Measurements%22">Radiation Measurements</searchLink>. Jan2016, Vol. 84, p55-64. 10p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Complementary+metal+oxide+semiconductors%22">Complementary metal oxide semiconductors</searchLink><br /><searchLink fieldCode="DE" term="%22Radiation+dosimetry%22">Radiation dosimetry</searchLink><br /><searchLink fieldCode="DE" term="%22Dosimeters%22">Dosimeters</searchLink><br /><searchLink fieldCode="DE" term="%22Systems+on+a+chip%22">Systems on a chip</searchLink><br /><searchLink fieldCode="DE" term="%22Radiotherapy%22">Radiotherapy</searchLink><br /><searchLink fieldCode="DE" term="%22High+resolution+imaging%22">High resolution imaging</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: The design, fabrication and testing of a novel monolithic system-on-chip dosimeter fabricated in a standard 180 nm CMOS technology is described. The device, implementing a radiation sensor and an RF transmitter, is proposed to address the need for real-time In Vivo Dosimetry (IVD) of radiation during Linac radiotherapy sessions. Owing to its small size, of approximately 1 mm 3 , such solution could be made in-body implantable and, as such, provide a much-enhanced high-resolution, real-time dose measurement to improve Quality Assurance (QA) in radiation therapy. The device transmits the related information on dose of radiation wirelessly to a remote receiver operating in the Medical Implant Communication Service (MICS) band. Comprehensive description of the various phases of this project, including the development of the radiation sensors and integrated RF transmitter to perform the readout, along with the final test results using a radiation beam, will be given. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Radiation Measurements is the property of Pergamon Press - An Imprint of Elsevier Science and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=112264890 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1016/j.radmeas.2015.11.004 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 10 StartPage: 55 Subjects: – SubjectFull: Complementary metal oxide semiconductors Type: general – SubjectFull: Radiation dosimetry Type: general – SubjectFull: Dosimeters Type: general – SubjectFull: Systems on a chip Type: general – SubjectFull: Radiotherapy Type: general – SubjectFull: High resolution imaging Type: general Titles: – TitleFull: A monolithic 180 nm CMOS dosimeter for wireless In Vivo Dosimetry. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Villani, E.G. – PersonEntity: Name: NameFull: Crepaldi, M. – PersonEntity: Name: NameFull: DeMarchi, D. – PersonEntity: Name: NameFull: Gabrielli, A. – PersonEntity: Name: NameFull: Khan, A. – PersonEntity: Name: NameFull: Pikhay, E. – PersonEntity: Name: NameFull: Roizin, Y. – PersonEntity: Name: NameFull: Rosenfeld, A. – PersonEntity: Name: NameFull: Zhang, Z. IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 01 Text: Jan2016 Type: published Y: 2016 Identifiers: – Type: issn-print Value: 13504487 Numbering: – Type: volume Value: 84 Titles: – TitleFull: Radiation Measurements Type: main |
| ResultId | 1 |