Abstract: This paper describes a computer-aided detection and diagnosis system for breast cancer, the most common form of cancer among women, using mammography. The system relies on the Multiple-Instance Learning (MIL) paradigm, which has proven useful for medical decision support in previous works from our team. In the proposed framework, breasts are first partitioned adaptively into regions. Then, features derived from the detection of lesions (masses and microcalcifications) as well as textural features, are extracted from each region and combined in order to classify mammography examinations as “normal” or “abnormal”. Whenever an abnormal examination record is detected, the regions that induced that automated diagnosis can be highlighted. Two strategies are evaluated to define this anomaly detector. In a first scenario, manual segmentations of lesions are used to train an SVM that assigns an anomaly index to each region; local anomaly indices are then combined into a global anomaly index. In a second scenario, the local and global anomaly detectors are trained simultaneously, without manual segmentations, using various MIL algorithms (DD, APR, mi-SVM, MI-SVM and MILBoost). Experiments on the DDSM dataset show that the second approach, which is only weakly-supervised, surprisingly outperforms the first approach, even though it is strongly-supervised. This suggests that anomaly detectors can be advantageously trained on large medical image archives, without the need for manual segmentation. [ABSTRACT FROM AUTHOR]
Copyright of IEEE Transactions on Medical Imaging is the property of IEEE and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Be the first to leave a comment!
You must be logged in first