Characteristics of microsecond-pulse surface flashover on epoxy resin surfaces in SF6.
Saved in:
| Title: | Characteristics of microsecond-pulse surface flashover on epoxy resin surfaces in SF6. |
|---|---|
| Authors: | Xie, Qing1, Wang, Yang1, Liu, Xiong2, Huang, He1, Zhang, Cheng3, Shao, Tao3 |
| Source: | IEEE Transactions on Dielectrics & Electrical Insulation. Aug2016, Vol. 23 Issue 4, p2328-2336. 9p. |
| Subjects: | Flashover, Epoxy insulators, Overvoltage, Scanning electron microscopy, Surface roughness |
| Abstract: | Surface flashover on insulating materials is likely to occur in composite apparatuses in overvoltage situations. In order to investigate the surface characteristics of epoxy resin (EP) materials, before and after flashover, microsecond pulses were applied to simulate transient overvoltage situations in a power system. Within the SF6 filled experimental chamber, pulse voltages with a frequency of 5 Hz and an amplitude of 25 kV were applied to induce surface flashover. The flashover characteristics of EP under different SF6 pressures were subsequently determined. The results show that the flashover voltage increases with increasing SF6 pressure. In addition, atomic force microscopy, scanning electron microscopy, and X-ray energy dispersive spectroscopy were performed to explore the morphology and elemental content of the material surfaces. During aging treatment, granular bulges were generated on the surface of the materials. With increasing treatment time, bulges first gathered and then became larger. Then, they became flattened as a result of burning due to electrical arcing. Thus, the surface roughness increased at first and then decreased. The material surface sequentially evolved into crack, granular, flocculent-granular, and then flocculent zones during the aging process, and these zones were distributed symmetrically in the aging area. Moreover, a large amount of flocculent substances (consisting of carbon and carbon compounds) accumulated near the electrodes. The insulating performance of the material surface was impaired by the aging treatment, which can be attributed to the combined effects of change in surface roughness and the discharge channel generated by surface carbonization. [ABSTRACT FROM AUTHOR] |
| Copyright of IEEE Transactions on Dielectrics & Electrical Insulation is the property of IEEE and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
| FullText | Text: Availability: 0 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 118004637 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Characteristics of microsecond-pulse surface flashover on epoxy resin surfaces in SF6. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Xie%2C+Qing%22">Xie, Qing</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Wang%2C+Yang%22">Wang, Yang</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Liu%2C+Xiong%22">Liu, Xiong</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Huang%2C+He%22">Huang, He</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Zhang%2C+Cheng%22">Zhang, Cheng</searchLink><relatesTo>3</relatesTo><br /><searchLink fieldCode="AR" term="%22Shao%2C+Tao%22">Shao, Tao</searchLink><relatesTo>3</relatesTo> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22IEEE+Transactions+on+Dielectrics+%26+Electrical+Insulation%22">IEEE Transactions on Dielectrics & Electrical Insulation</searchLink>. Aug2016, Vol. 23 Issue 4, p2328-2336. 9p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Flashover%22">Flashover</searchLink><br /><searchLink fieldCode="DE" term="%22Epoxy+insulators%22">Epoxy insulators</searchLink><br /><searchLink fieldCode="DE" term="%22Overvoltage%22">Overvoltage</searchLink><br /><searchLink fieldCode="DE" term="%22Scanning+electron+microscopy%22">Scanning electron microscopy</searchLink><br /><searchLink fieldCode="DE" term="%22Surface+roughness%22">Surface roughness</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: Surface flashover on insulating materials is likely to occur in composite apparatuses in overvoltage situations. In order to investigate the surface characteristics of epoxy resin (EP) materials, before and after flashover, microsecond pulses were applied to simulate transient overvoltage situations in a power system. Within the SF6 filled experimental chamber, pulse voltages with a frequency of 5 Hz and an amplitude of 25 kV were applied to induce surface flashover. The flashover characteristics of EP under different SF6 pressures were subsequently determined. The results show that the flashover voltage increases with increasing SF6 pressure. In addition, atomic force microscopy, scanning electron microscopy, and X-ray energy dispersive spectroscopy were performed to explore the morphology and elemental content of the material surfaces. During aging treatment, granular bulges were generated on the surface of the materials. With increasing treatment time, bulges first gathered and then became larger. Then, they became flattened as a result of burning due to electrical arcing. Thus, the surface roughness increased at first and then decreased. The material surface sequentially evolved into crack, granular, flocculent-granular, and then flocculent zones during the aging process, and these zones were distributed symmetrically in the aging area. Moreover, a large amount of flocculent substances (consisting of carbon and carbon compounds) accumulated near the electrodes. The insulating performance of the material surface was impaired by the aging treatment, which can be attributed to the combined effects of change in surface roughness and the discharge channel generated by surface carbonization. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of IEEE Transactions on Dielectrics & Electrical Insulation is the property of IEEE and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=118004637 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1109/TDEI.2016.7556510 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 9 StartPage: 2328 Subjects: – SubjectFull: Flashover Type: general – SubjectFull: Epoxy insulators Type: general – SubjectFull: Overvoltage Type: general – SubjectFull: Scanning electron microscopy Type: general – SubjectFull: Surface roughness Type: general Titles: – TitleFull: Characteristics of microsecond-pulse surface flashover on epoxy resin surfaces in SF6. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Xie, Qing – PersonEntity: Name: NameFull: Wang, Yang – PersonEntity: Name: NameFull: Liu, Xiong – PersonEntity: Name: NameFull: Huang, He – PersonEntity: Name: NameFull: Zhang, Cheng – PersonEntity: Name: NameFull: Shao, Tao IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 08 Text: Aug2016 Type: published Y: 2016 Identifiers: – Type: issn-print Value: 10709878 Numbering: – Type: volume Value: 23 – Type: issue Value: 4 Titles: – TitleFull: IEEE Transactions on Dielectrics & Electrical Insulation Type: main |
| ResultId | 1 |