Impedimetric sensor for Leishmania infantum genome based on gold nanoparticles dispersed in polyaniline matrix.

Saved in:
Bibliographic Details
Title: Impedimetric sensor for Leishmania infantum genome based on gold nanoparticles dispersed in polyaniline matrix.
Authors: Garcia, Maria FK dos S1, Andrade, Cesar AS2, de Melo, Celso P3, Gomes, Daliane S2, Silva, Lidiane G4, Dias, Raimundo V5, Balbino, Valdir Q4, Oliveira, Maria DL1,2 m_danielly@yahoo.com.br
Source: Journal of Chemical Technology & Biotechnology. Nov2016, Vol. 91 Issue 11, p2810-2816. 7p.
Subjects: Biosensors, Leishmania infantum, Gold nanoparticles, Polyanilines, Scanning electron microscopy, Oxidation-reduction reaction
Abstract: BACKGROUND In this work, an electrochemical sensor for specific detection of Leishmania infantum genome ( LiG) was developed. The sensorial system is based on the immobilization of a DNA probe onto a gold electrode surface previously covered with a simple and effective layer of a SH-terminal group on polyaniline matrix containing gold nanoparticles ( PANIAuNp). Scanning electron microscopy ( SEM), cyclic voltammetry ( CV), and electrochemical impedance ( EI) techniques were applied to evaluate the immobilization of L. infantum primer ( LiP) on PANIAuNp. RESULTS SEM images for AuNpPANI-probe systems indicate that the film of the hybridized biomolecules was homogenous, compact and dense. Experimental results indicate that even when immobilized the probe retained its bioactivity. The primer-genome interaction was evaluated by cyclic voltammetry ( CV) and electrochemical impedance spectroscopy ( EIS) using a K4[Fe( CN)6]4−/ K3[Fe( CN)6]3− redox pair. Both CV and EIS results have shown unequivocal evidence that the sensor presents specific detection of LiG based on primer-genome interactions. The LiG detection is translated as observable changes in the charge transfer resistance and the cathodic/anodic peak current. A stepwise modification on the bare gold electrode is accompanied not only by a decrease in its amperometric response, but also by an increase in the peak-to-peak separation between the cathodic and anodic waves of the redox probe. The sensor response to actual positive samples obtained from contaminated dogs was also evaluated. CONCLUSION Results indicate that it is feasible to use this biosensor to detect LiG even at low concentrations (0.01 pg mL−1). © 2016 Society of Chemical Industry [ABSTRACT FROM AUTHOR]
Copyright of Journal of Chemical Technology & Biotechnology is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 118279850
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Impedimetric sensor for Leishmania infantum genome based on gold nanoparticles dispersed in polyaniline matrix.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Garcia%2C+Maria+FK+dos+S%22">Garcia, Maria FK dos S</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Andrade%2C+Cesar+AS%22">Andrade, Cesar AS</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22de+Melo%2C+Celso+P%22">de Melo, Celso P</searchLink><relatesTo>3</relatesTo><br /><searchLink fieldCode="AR" term="%22Gomes%2C+Daliane+S%22">Gomes, Daliane S</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Silva%2C+Lidiane+G%22">Silva, Lidiane G</searchLink><relatesTo>4</relatesTo><br /><searchLink fieldCode="AR" term="%22Dias%2C+Raimundo+V%22">Dias, Raimundo V</searchLink><relatesTo>5</relatesTo><br /><searchLink fieldCode="AR" term="%22Balbino%2C+Valdir+Q%22">Balbino, Valdir Q</searchLink><relatesTo>4</relatesTo><br /><searchLink fieldCode="AR" term="%22Oliveira%2C+Maria+DL%22">Oliveira, Maria DL</searchLink><relatesTo>1,2</relatesTo><i> m_danielly@yahoo.com.br</i>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Journal+of+Chemical+Technology+%26+Biotechnology%22">Journal of Chemical Technology & Biotechnology</searchLink>. Nov2016, Vol. 91 Issue 11, p2810-2816. 7p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Biosensors%22">Biosensors</searchLink><br /><searchLink fieldCode="DE" term="%22Leishmania+infantum%22">Leishmania infantum</searchLink><br /><searchLink fieldCode="DE" term="%22Gold+nanoparticles%22">Gold nanoparticles</searchLink><br /><searchLink fieldCode="DE" term="%22Polyanilines%22">Polyanilines</searchLink><br /><searchLink fieldCode="DE" term="%22Scanning+electron+microscopy%22">Scanning electron microscopy</searchLink><br /><searchLink fieldCode="DE" term="%22Oxidation-reduction+reaction%22">Oxidation-reduction reaction</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: BACKGROUND In this work, an electrochemical sensor for specific detection of Leishmania infantum genome ( LiG) was developed. The sensorial system is based on the immobilization of a DNA probe onto a gold electrode surface previously covered with a simple and effective layer of a SH-terminal group on polyaniline matrix containing gold nanoparticles ( PANIAuNp). Scanning electron microscopy ( SEM), cyclic voltammetry ( CV), and electrochemical impedance ( EI) techniques were applied to evaluate the immobilization of L. infantum primer ( LiP) on PANIAuNp. RESULTS SEM images for AuNpPANI-probe systems indicate that the film of the hybridized biomolecules was homogenous, compact and dense. Experimental results indicate that even when immobilized the probe retained its bioactivity. The primer-genome interaction was evaluated by cyclic voltammetry ( CV) and electrochemical impedance spectroscopy ( EIS) using a K4[Fe( CN)6]4−/ K3[Fe( CN)6]3− redox pair. Both CV and EIS results have shown unequivocal evidence that the sensor presents specific detection of LiG based on primer-genome interactions. The LiG detection is translated as observable changes in the charge transfer resistance and the cathodic/anodic peak current. A stepwise modification on the bare gold electrode is accompanied not only by a decrease in its amperometric response, but also by an increase in the peak-to-peak separation between the cathodic and anodic waves of the redox probe. The sensor response to actual positive samples obtained from contaminated dogs was also evaluated. CONCLUSION Results indicate that it is feasible to use this biosensor to detect LiG even at low concentrations (0.01 pg mL−1). © 2016 Society of Chemical Industry [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Journal of Chemical Technology & Biotechnology is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=118279850
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1002/jctb.4890
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 7
        StartPage: 2810
    Subjects:
      – SubjectFull: Biosensors
        Type: general
      – SubjectFull: Leishmania infantum
        Type: general
      – SubjectFull: Gold nanoparticles
        Type: general
      – SubjectFull: Polyanilines
        Type: general
      – SubjectFull: Scanning electron microscopy
        Type: general
      – SubjectFull: Oxidation-reduction reaction
        Type: general
    Titles:
      – TitleFull: Impedimetric sensor for Leishmania infantum genome based on gold nanoparticles dispersed in polyaniline matrix.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Garcia, Maria FK dos S
      – PersonEntity:
          Name:
            NameFull: Andrade, Cesar AS
      – PersonEntity:
          Name:
            NameFull: de Melo, Celso P
      – PersonEntity:
          Name:
            NameFull: Gomes, Daliane S
      – PersonEntity:
          Name:
            NameFull: Silva, Lidiane G
      – PersonEntity:
          Name:
            NameFull: Dias, Raimundo V
      – PersonEntity:
          Name:
            NameFull: Balbino, Valdir Q
      – PersonEntity:
          Name:
            NameFull: Oliveira, Maria DL
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 11
              Text: Nov2016
              Type: published
              Y: 2016
          Identifiers:
            – Type: issn-print
              Value: 02682575
          Numbering:
            – Type: volume
              Value: 91
            – Type: issue
              Value: 11
          Titles:
            – TitleFull: Journal of Chemical Technology & Biotechnology
              Type: main
ResultId 1