Blood oxygen-level dependent functional assessment of cerebrovascular reactivity: Feasibility for intraoperative 3 Tesla MRI.

Saved in:
Bibliographic Details
Title: Blood oxygen-level dependent functional assessment of cerebrovascular reactivity: Feasibility for intraoperative 3 Tesla MRI.
Authors: Fierstra, Jorn1 jorn.fierstra@usz.ch, Burkhardt, Jan‐Karl1, van Niftrik, Christiaan Hendrik Bas1, Piccirelli, Marco2, Pangalu, Athina2, Kocian, Roman3, Neidert, Marian Christoph1, Valavanis, Antonios2, Regli, Luca1, Bozinov, Oliver1
Source: Magnetic Resonance in Medicine. Feb2017, Vol. 77 Issue 2, p806-813. 8p.
Abstract: Purpose To assess the feasibility of functional blood oxygen-level dependent (BOLD) MRI to evaluate intraoperative cerebrovascular reactivity (CVR) at 3 Tesla field strength. Methods Ten consecutive neurosurgical subjects scheduled for a clinical intraoperative MRI examination were enrolled in this study. In addition to the clinical protocol a BOLD sequence was implemented with three cycles of 44 s apnea to calculate CVR values on a voxel-by-voxel basis throughout the brain. The CVR range was then color-coded and superimposed on an anatomical volume to create high spatial resolution CVR maps. Results Ten subjects (mean age 34.8 ± 13.4; 2 females) uneventfully underwent the intraoperative BOLD protocol, with no complications occurring. Whole-brain CVR for all subjects was (mean ± SD) 0.69 ± 0.42, whereas CVR was markedly higher for tumor subjects as compared to vascular subjects, 0.81 ± 0.44 versus 0.33 ± 0.10, respectively. Furthermore, color-coded functional maps could be robustly interpreted for a whole-brain assessment of CVR. Conclusion We demonstrate that intraoperative BOLD MRI is feasible in creating functional maps to assess cerebrovascular reactivity throughout the brain in subjects undergoing a neurosurgical procedure. Magn Reson Med 77:806-813, 2017. © 2016 International Society for Magnetic Resonance in Medicine [ABSTRACT FROM AUTHOR]
Copyright of Magnetic Resonance in Medicine is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Links:
  – Type: pdflink
Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 120846101
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Blood oxygen-level dependent functional assessment of cerebrovascular reactivity: Feasibility for intraoperative 3 Tesla MRI.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Fierstra%2C+Jorn%22">Fierstra, Jorn</searchLink><relatesTo>1</relatesTo><i> jorn.fierstra@usz.ch</i><br /><searchLink fieldCode="AR" term="%22Burkhardt%2C+Jan‐Karl%22">Burkhardt, Jan‐Karl</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22van+Niftrik%2C+Christiaan+Hendrik+Bas%22">van Niftrik, Christiaan Hendrik Bas</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Piccirelli%2C+Marco%22">Piccirelli, Marco</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Pangalu%2C+Athina%22">Pangalu, Athina</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Kocian%2C+Roman%22">Kocian, Roman</searchLink><relatesTo>3</relatesTo><br /><searchLink fieldCode="AR" term="%22Neidert%2C+Marian+Christoph%22">Neidert, Marian Christoph</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Valavanis%2C+Antonios%22">Valavanis, Antonios</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Regli%2C+Luca%22">Regli, Luca</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Bozinov%2C+Oliver%22">Bozinov, Oliver</searchLink><relatesTo>1</relatesTo>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Magnetic+Resonance+in+Medicine%22">Magnetic Resonance in Medicine</searchLink>. Feb2017, Vol. 77 Issue 2, p806-813. 8p.
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Purpose To assess the feasibility of functional blood oxygen-level dependent (BOLD) MRI to evaluate intraoperative cerebrovascular reactivity (CVR) at 3 Tesla field strength. Methods Ten consecutive neurosurgical subjects scheduled for a clinical intraoperative MRI examination were enrolled in this study. In addition to the clinical protocol a BOLD sequence was implemented with three cycles of 44 s apnea to calculate CVR values on a voxel-by-voxel basis throughout the brain. The CVR range was then color-coded and superimposed on an anatomical volume to create high spatial resolution CVR maps. Results Ten subjects (mean age 34.8 ± 13.4; 2 females) uneventfully underwent the intraoperative BOLD protocol, with no complications occurring. Whole-brain CVR for all subjects was (mean ± SD) 0.69 ± 0.42, whereas CVR was markedly higher for tumor subjects as compared to vascular subjects, 0.81 ± 0.44 versus 0.33 ± 0.10, respectively. Furthermore, color-coded functional maps could be robustly interpreted for a whole-brain assessment of CVR. Conclusion We demonstrate that intraoperative BOLD MRI is feasible in creating functional maps to assess cerebrovascular reactivity throughout the brain in subjects undergoing a neurosurgical procedure. Magn Reson Med 77:806-813, 2017. © 2016 International Society for Magnetic Resonance in Medicine [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Magnetic Resonance in Medicine is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=120846101
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1002/mrm.26135
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 8
        StartPage: 806
    Titles:
      – TitleFull: Blood oxygen-level dependent functional assessment of cerebrovascular reactivity: Feasibility for intraoperative 3 Tesla MRI.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Fierstra, Jorn
      – PersonEntity:
          Name:
            NameFull: Burkhardt, Jan‐Karl
      – PersonEntity:
          Name:
            NameFull: van Niftrik, Christiaan Hendrik Bas
      – PersonEntity:
          Name:
            NameFull: Piccirelli, Marco
      – PersonEntity:
          Name:
            NameFull: Pangalu, Athina
      – PersonEntity:
          Name:
            NameFull: Kocian, Roman
      – PersonEntity:
          Name:
            NameFull: Neidert, Marian Christoph
      – PersonEntity:
          Name:
            NameFull: Valavanis, Antonios
      – PersonEntity:
          Name:
            NameFull: Regli, Luca
      – PersonEntity:
          Name:
            NameFull: Bozinov, Oliver
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 02
              Text: Feb2017
              Type: published
              Y: 2017
          Identifiers:
            – Type: issn-print
              Value: 07403194
          Numbering:
            – Type: volume
              Value: 77
            – Type: issue
              Value: 2
          Titles:
            – TitleFull: Magnetic Resonance in Medicine
              Type: main
ResultId 1