A dynamic simulator for the ergonomics evaluation of powered torque tools for human assembly.
Saved in:
| Title: | A dynamic simulator for the ergonomics evaluation of powered torque tools for human assembly. |
|---|---|
| Authors: | Ay, Haluk1,2,3 halukay6322@gmail.com, Luscher, Anthony1,2,3 luscher.3@osu.edu, Sommerich, Carolyn1,2,3 sommerich.1@osu.edu |
| Source: | Assembly Automation. 2017, Vol. 37 Issue 1, p1-12. 12p. |
| Subjects: | Ergonomics, Assembly line balancing, Computer-control machine tool operators |
| Abstract: | Purpose The purpose of this study is to design and develop a testing device to simulate interaction between human hand–arm dynamics, right-angle (RA) computer-controlled power torque tools and joint-tightening task-related variables.Design/methodology/approach The testing rig can simulate a variety of tools, tasks and operator conditions. The device includes custom data-acquisition electronics and graphical user interface-based software. The simulation of the human hand–arm dynamics is based on the rig’s four-bar mechanism-based design and mechanical components that provide adjustable stiffness (via pneumatic cylinder) and mass (via plates) and non-adjustable damping. The stiffness and mass values used are based on an experimentally validated hand–arm model that includes a database of model parameters. This database is with respect to gender and working posture, corresponding to experienced tool operators from a prior study.Findings The rig measures tool handle force and displacement responses simultaneously. Peak force and displacement coefficients of determination (R2) between rig estimations and human testing measurements were 0.98 and 0.85, respectively, for the same set of tools, tasks and operator conditions. The rig also provides predicted tool operator acceptability ratings, using a data set from a prior study of discomfort in experienced operators during torque tool use.Research limitations/implications Deviations from linearity may influence handle force and displacement measurements. Stiction (Coulomb friction) in the overall rig, as well as in the air cylinder piston, is neglected. The rig’s mechanical damping is not adjustable, despite the fact that human hand–arm damping varies with respect to gender and working posture. Deviations from these assumptions may affect the correlation of the handle force and displacement measurements with those of human testing for the same tool, task and operator conditions.Practical implications This test rig will allow the rapid assessment of the ergonomic performance of DC torque tools, saving considerable time in lineside applications and reducing the risk of worker injury. DC torque tools are an extremely effective way of increasing production rate and improving torque accuracy. Being a complex dynamic system, however, the performance of DC torque tools varies in each application. Changes in worker mass, damping and stiffness, as well as joint stiffness and tool program, make each application unique. This test rig models all of these factors and allows quick assessment.Social implications The use of this tool test rig will help to identify and understand risk factors that contribute to musculoskeletal disorders (MSDs) associated with the use of torque tools. Tool operators are subjected to large impulsive handle reaction forces, as joint torque builds up while tightening a fastener. Repeated exposure to such forces is associated with muscle soreness, fatigue and physical stress which are also risk factors for upper extremity injuries (MSDs; e.g. tendinosis, myofascial pain). Eccentric exercise exertions are known to cause damage to muscle tissue in untrained individuals and affect subsequent performance.Originality/value The rig provides a novel means for quantitative, repeatable dynamic evaluation of RA powered torque tools and objective selection of tightening programs. Compared to current static tool assessment methods, dynamic testing provides a more realistic tool assessment relative to the tool operator’s experience. This may lead to improvements in tool or controller design and reduction in associated musculoskeletal discomfort in operators. [ABSTRACT FROM AUTHOR] |
| Copyright of Assembly Automation is the property of Emerald Publishing Limited and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
| FullText | Text: Availability: 0 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 120969956 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: A dynamic simulator for the ergonomics evaluation of powered torque tools for human assembly. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Ay%2C+Haluk%22">Ay, Haluk</searchLink><relatesTo>1,2,3</relatesTo><i> halukay6322@gmail.com</i><br /><searchLink fieldCode="AR" term="%22Luscher%2C+Anthony%22">Luscher, Anthony</searchLink><relatesTo>1,2,3</relatesTo><i> luscher.3@osu.edu</i><br /><searchLink fieldCode="AR" term="%22Sommerich%2C+Carolyn%22">Sommerich, Carolyn</searchLink><relatesTo>1,2,3</relatesTo><i> sommerich.1@osu.edu</i> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Assembly+Automation%22">Assembly Automation</searchLink>. 2017, Vol. 37 Issue 1, p1-12. 12p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Ergonomics%22">Ergonomics</searchLink><br /><searchLink fieldCode="DE" term="%22Assembly+line+balancing%22">Assembly line balancing</searchLink><br /><searchLink fieldCode="DE" term="%22Computer-control+machine+tool+operators%22">Computer-control machine tool operators</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: Purpose The purpose of this study is to design and develop a testing device to simulate interaction between human hand–arm dynamics, right-angle (RA) computer-controlled power torque tools and joint-tightening task-related variables.Design/methodology/approach The testing rig can simulate a variety of tools, tasks and operator conditions. The device includes custom data-acquisition electronics and graphical user interface-based software. The simulation of the human hand–arm dynamics is based on the rig’s four-bar mechanism-based design and mechanical components that provide adjustable stiffness (via pneumatic cylinder) and mass (via plates) and non-adjustable damping. The stiffness and mass values used are based on an experimentally validated hand–arm model that includes a database of model parameters. This database is with respect to gender and working posture, corresponding to experienced tool operators from a prior study.Findings The rig measures tool handle force and displacement responses simultaneously. Peak force and displacement coefficients of determination (R2) between rig estimations and human testing measurements were 0.98 and 0.85, respectively, for the same set of tools, tasks and operator conditions. The rig also provides predicted tool operator acceptability ratings, using a data set from a prior study of discomfort in experienced operators during torque tool use.Research limitations/implications Deviations from linearity may influence handle force and displacement measurements. Stiction (Coulomb friction) in the overall rig, as well as in the air cylinder piston, is neglected. The rig’s mechanical damping is not adjustable, despite the fact that human hand–arm damping varies with respect to gender and working posture. Deviations from these assumptions may affect the correlation of the handle force and displacement measurements with those of human testing for the same tool, task and operator conditions.Practical implications This test rig will allow the rapid assessment of the ergonomic performance of DC torque tools, saving considerable time in lineside applications and reducing the risk of worker injury. DC torque tools are an extremely effective way of increasing production rate and improving torque accuracy. Being a complex dynamic system, however, the performance of DC torque tools varies in each application. Changes in worker mass, damping and stiffness, as well as joint stiffness and tool program, make each application unique. This test rig models all of these factors and allows quick assessment.Social implications The use of this tool test rig will help to identify and understand risk factors that contribute to musculoskeletal disorders (MSDs) associated with the use of torque tools. Tool operators are subjected to large impulsive handle reaction forces, as joint torque builds up while tightening a fastener. Repeated exposure to such forces is associated with muscle soreness, fatigue and physical stress which are also risk factors for upper extremity injuries (MSDs; e.g. tendinosis, myofascial pain). Eccentric exercise exertions are known to cause damage to muscle tissue in untrained individuals and affect subsequent performance.Originality/value The rig provides a novel means for quantitative, repeatable dynamic evaluation of RA powered torque tools and objective selection of tightening programs. Compared to current static tool assessment methods, dynamic testing provides a more realistic tool assessment relative to the tool operator’s experience. This may lead to improvements in tool or controller design and reduction in associated musculoskeletal discomfort in operators. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Assembly Automation is the property of Emerald Publishing Limited and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=120969956 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1108/AA-12-2015-126 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 12 StartPage: 1 Subjects: – SubjectFull: Ergonomics Type: general – SubjectFull: Assembly line balancing Type: general – SubjectFull: Computer-control machine tool operators Type: general Titles: – TitleFull: A dynamic simulator for the ergonomics evaluation of powered torque tools for human assembly. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Ay, Haluk – PersonEntity: Name: NameFull: Luscher, Anthony – PersonEntity: Name: NameFull: Sommerich, Carolyn IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 01 Text: 2017 Type: published Y: 2017 Identifiers: – Type: issn-print Value: 01445154 Numbering: – Type: volume Value: 37 – Type: issue Value: 1 Titles: – TitleFull: Assembly Automation Type: main |
| ResultId | 1 |