A new paramagnetically shifted imaging probe for MRI.

Saved in:
Bibliographic Details
Title: A new paramagnetically shifted imaging probe for MRI.
Authors: Senanayake, P. Kanthi1, Rogers, Nicola J.1, Finney, Katie‐Louise N.A.1, Harvey, Peter1, Funk, Alexander M.1, Wilson, J. Ian2, O'Hogain, Dara3, Maxwell, Ross2, Parker, David1, Blamire, Andrew M.3 andrew.blamire@newcastle.ac.uk
Source: Magnetic Resonance in Medicine. Mar2017, Vol. 77 Issue 3, p1307-1317. 11p.
Abstract: Purpose To develop and characterize a new paramagnetic contrast agent for molecular imaging by MRI. Methods A contrast agent was developed for direct MRI detection through the paramagnetically shifted proton magnetic resonances of two chemically equivalent tert-butyl reporter groups within a dysprosium(III) complex. The complex was characterized in phantoms and imaged in physiologically intact mice at 7 Tesla (T) using three-dimensional (3D) gradient echo and spectroscopic imaging (MRSI) sequences to measure spatial distribution and signal frequency. Results The reporter protons reside ∼6.5 Å from the paramagnetic center, resulting in fast T1 relaxation ( T1 = 8 ms) and a large paramagnetic frequency shift exceeding 60 ppm. Fast relaxation allowed short scan repetition times with high excitation flip angle, resulting in high sensitivity. The large dipolar shift allowed direct frequency selective excitation and acquisition of the dysprosium(III) complex, independent of the tissue water signal. The biokinetics of the complex were followed in vivo with a temporal resolution of 62 s following a single, low-dose intravenous injection. The lower concentration limit for detection was ∼23 μM. Through MRSI, the temperature dependence of the paramagnetic shift (0.28 ppm.K−1) was exploited to examine tissue temperature variation. Conclusions These data demonstrate a new MRI agent with the potential for physiological monitoring by MRI. Magn Reson Med 77:1307-1317, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. [ABSTRACT FROM AUTHOR]
Copyright of Magnetic Resonance in Medicine is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Links:
  – Type: pdflink
Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 121289697
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: A new paramagnetically shifted imaging probe for MRI.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Senanayake%2C+P%2E+Kanthi%22">Senanayake, P. Kanthi</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Rogers%2C+Nicola+J%2E%22">Rogers, Nicola J.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Finney%2C+Katie‐Louise+N%2EA%2E%22">Finney, Katie‐Louise N.A.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Harvey%2C+Peter%22">Harvey, Peter</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Funk%2C+Alexander+M%2E%22">Funk, Alexander M.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Wilson%2C+J%2E+Ian%22">Wilson, J. Ian</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22O'Hogain%2C+Dara%22">O'Hogain, Dara</searchLink><relatesTo>3</relatesTo><br /><searchLink fieldCode="AR" term="%22Maxwell%2C+Ross%22">Maxwell, Ross</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Parker%2C+David%22">Parker, David</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Blamire%2C+Andrew+M%2E%22">Blamire, Andrew M.</searchLink><relatesTo>3</relatesTo><i> andrew.blamire@newcastle.ac.uk</i>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Magnetic+Resonance+in+Medicine%22">Magnetic Resonance in Medicine</searchLink>. Mar2017, Vol. 77 Issue 3, p1307-1317. 11p.
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Purpose To develop and characterize a new paramagnetic contrast agent for molecular imaging by MRI. Methods A contrast agent was developed for direct MRI detection through the paramagnetically shifted proton magnetic resonances of two chemically equivalent tert-butyl reporter groups within a dysprosium(III) complex. The complex was characterized in phantoms and imaged in physiologically intact mice at 7 Tesla (T) using three-dimensional (3D) gradient echo and spectroscopic imaging (MRSI) sequences to measure spatial distribution and signal frequency. Results The reporter protons reside ∼6.5 Å from the paramagnetic center, resulting in fast T1 relaxation ( T1 = 8 ms) and a large paramagnetic frequency shift exceeding 60 ppm. Fast relaxation allowed short scan repetition times with high excitation flip angle, resulting in high sensitivity. The large dipolar shift allowed direct frequency selective excitation and acquisition of the dysprosium(III) complex, independent of the tissue water signal. The biokinetics of the complex were followed in vivo with a temporal resolution of 62 s following a single, low-dose intravenous injection. The lower concentration limit for detection was ∼23 μM. Through MRSI, the temperature dependence of the paramagnetic shift (0.28 ppm.K−1) was exploited to examine tissue temperature variation. Conclusions These data demonstrate a new MRI agent with the potential for physiological monitoring by MRI. Magn Reson Med 77:1307-1317, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Magnetic Resonance in Medicine is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=121289697
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1002/mrm.26185
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 11
        StartPage: 1307
    Titles:
      – TitleFull: A new paramagnetically shifted imaging probe for MRI.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Senanayake, P. Kanthi
      – PersonEntity:
          Name:
            NameFull: Rogers, Nicola J.
      – PersonEntity:
          Name:
            NameFull: Finney, Katie‐Louise N.A.
      – PersonEntity:
          Name:
            NameFull: Harvey, Peter
      – PersonEntity:
          Name:
            NameFull: Funk, Alexander M.
      – PersonEntity:
          Name:
            NameFull: Wilson, J. Ian
      – PersonEntity:
          Name:
            NameFull: O'Hogain, Dara
      – PersonEntity:
          Name:
            NameFull: Maxwell, Ross
      – PersonEntity:
          Name:
            NameFull: Parker, David
      – PersonEntity:
          Name:
            NameFull: Blamire, Andrew M.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 03
              Text: Mar2017
              Type: published
              Y: 2017
          Identifiers:
            – Type: issn-print
              Value: 07403194
          Numbering:
            – Type: volume
              Value: 77
            – Type: issue
              Value: 3
          Titles:
            – TitleFull: Magnetic Resonance in Medicine
              Type: main
ResultId 1