Effect of radiant heat on conventional glass ionomer cements during setting by using a blue light diode laser system (445 nm).

Saved in:
Bibliographic Details
Title: Effect of radiant heat on conventional glass ionomer cements during setting by using a blue light diode laser system (445 nm).
Authors: Dionysopoulos, Dimitrios1 ddiondent@gmail.com, Tolidis, Kosmas1, Strakas, Dimitrios1, Gerasimou, Paris1, Sfeikos, Thrasyvoulos1, Gutknecht, Norbert2
Source: Lasers in Medical Science. Apr2017, Vol. 32 Issue 3, p703-709. 7p.
Subjects: Dental glass ionomer cements, Radiant heating, Blue light emitting diodes, Semiconductor lasers, In vitro studies, Heat, Lasers, Materials testing, Physics, Scanning electron microscopy
Abstract: The aim of this in vitro study was to evaluate the effect of radiant heat on surface hardness of three conventional glass ionomer cements (GICs) by using a blue diode laser system (445 nm) and a light-emitting diode (LED) unit. Additionally, the safety of the laser treatment was evaluated. Thirty disk-shaped specimens were prepared of each tested GIC (Equia Fil, Ketac Universal Aplicap and Riva Self Cure). The experimental groups (n = 10) of the study were as follows: group 1 was the control group of the study; in group 2, the specimens were irradiated for 60 s at the top surface using a LED light-curing unit; and in group 3, the specimens were irradiated for 60 s at the top surface using a blue light diode laser system (445 nm). Statistical analysis was performed using one-way ANOVA and Tukey post-hoc tests at a level of significance of a = 0.05. Radiant heat treatments, with both laser and LED devices, increased surface hardness (p < 0.05) but in different extent. Blue diode laser treatment was seemed to be more effective compared to LED treatment. There were no alterations in surface morphology or chemical composition after laser treatment. The tested radiant heat treatment with a blue diode laser may be advantageous for the longevity of GIC restorations. The safety of the use of blue diode laser for this application was confirmed. [ABSTRACT FROM AUTHOR]
Copyright of Lasers in Medical Science is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Links:
  – Type: pdflink
Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 121976601
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Effect of radiant heat on conventional glass ionomer cements during setting by using a blue light diode laser system (445&#160;nm).
– Name: Author
  Label: Authors
  Group: Au
  Data: &lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Dionysopoulos%2C+Dimitrios%22&quot;&gt;Dionysopoulos, Dimitrios&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt;&lt;i&gt; ddiondent@gmail.com&lt;/i&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Tolidis%2C+Kosmas%22&quot;&gt;Tolidis, Kosmas&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Strakas%2C+Dimitrios%22&quot;&gt;Strakas, Dimitrios&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Gerasimou%2C+Paris%22&quot;&gt;Gerasimou, Paris&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Sfeikos%2C+Thrasyvoulos%22&quot;&gt;Sfeikos, Thrasyvoulos&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Gutknecht%2C+Norbert%22&quot;&gt;Gutknecht, Norbert&lt;/searchLink&gt;&lt;relatesTo&gt;2&lt;/relatesTo&gt;
– Name: TitleSource
  Label: Source
  Group: Src
  Data: &lt;searchLink fieldCode=&quot;JN&quot; term=&quot;%22Lasers+in+Medical+Science%22&quot;&gt;Lasers in Medical Science&lt;/searchLink&gt;. Apr2017, Vol. 32 Issue 3, p703-709. 7p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: &lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Dental+glass+ionomer+cements%22&quot;&gt;Dental glass ionomer cements&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Radiant+heating%22&quot;&gt;Radiant heating&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Blue+light+emitting+diodes%22&quot;&gt;Blue light emitting diodes&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Semiconductor+lasers%22&quot;&gt;Semiconductor lasers&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22In+vitro+studies%22&quot;&gt;In vitro studies&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Heat%22&quot;&gt;Heat&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Lasers%22&quot;&gt;Lasers&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Materials+testing%22&quot;&gt;Materials testing&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Physics%22&quot;&gt;Physics&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Scanning+electron+microscopy%22&quot;&gt;Scanning electron microscopy&lt;/searchLink&gt;
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: The aim of this in vitro study was to evaluate the effect of radiant heat on surface hardness of three conventional glass ionomer cements (GICs) by using a blue diode laser system (445&#160;nm) and a light-emitting diode (LED) unit. Additionally, the safety of the laser treatment was evaluated. Thirty disk-shaped specimens were prepared of each tested GIC (Equia Fil, Ketac Universal Aplicap and Riva Self Cure). The experimental groups (n = 10) of the study were as follows: group 1 was the control group of the study; in group 2, the specimens were irradiated for 60&#160;s at the top surface using a LED light-curing unit; and in group 3, the specimens were irradiated for 60&#160;s at the top surface using a blue light diode laser system (445&#160;nm). Statistical analysis was performed using one-way ANOVA and Tukey post-hoc tests at a level of significance of a = 0.05. Radiant heat treatments, with both laser and LED devices, increased surface hardness (p &lt; 0.05) but in different extent. Blue diode laser treatment was seemed to be more effective compared to LED treatment. There were no alterations in surface morphology or chemical composition after laser treatment. The tested radiant heat treatment with a blue diode laser may be advantageous for the longevity of GIC restorations. The safety of the use of blue diode laser for this application was confirmed. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: &lt;i&gt;Copyright of Lasers in Medical Science is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder&#39;s express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.&lt;/i&gt; (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=121976601
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1007/s10103-017-2178-x
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 7
        StartPage: 703
    Subjects:
      – SubjectFull: Dental glass ionomer cements
        Type: general
      – SubjectFull: Radiant heating
        Type: general
      – SubjectFull: Blue light emitting diodes
        Type: general
      – SubjectFull: Semiconductor lasers
        Type: general
      – SubjectFull: In vitro studies
        Type: general
      – SubjectFull: Heat
        Type: general
      – SubjectFull: Lasers
        Type: general
      – SubjectFull: Materials testing
        Type: general
      – SubjectFull: Physics
        Type: general
      – SubjectFull: Scanning electron microscopy
        Type: general
    Titles:
      – TitleFull: Effect of radiant heat on conventional glass ionomer cements during setting by using a blue light diode laser system (445 nm).
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Dionysopoulos, Dimitrios
      – PersonEntity:
          Name:
            NameFull: Tolidis, Kosmas
      – PersonEntity:
          Name:
            NameFull: Strakas, Dimitrios
      – PersonEntity:
          Name:
            NameFull: Gerasimou, Paris
      – PersonEntity:
          Name:
            NameFull: Sfeikos, Thrasyvoulos
      – PersonEntity:
          Name:
            NameFull: Gutknecht, Norbert
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 04
              Text: Apr2017
              Type: published
              Y: 2017
          Identifiers:
            – Type: issn-print
              Value: 02688921
          Numbering:
            – Type: volume
              Value: 32
            – Type: issue
              Value: 3
          Titles:
            – TitleFull: Lasers in Medical Science
              Type: main
ResultId 1