CT imaging before transcatheter aortic valve implantation (TAVI) using variable helical pitch scanning and its diagnostic performance for coronary artery disease.

Saved in:
Bibliographic Details
Title: CT imaging before transcatheter aortic valve implantation (TAVI) using variable helical pitch scanning and its diagnostic performance for coronary artery disease.
Authors: Matsumoto, Shunsuke1, Yamada, Yoshitake1 yamada@rad.med.keio.ac.jp, Hashimoto, Masahiro1, Okamura, Teppei1, Yamada, Minoru2, Yashima, Fumiaki3, Hayashida, Kentaro3, Fukuda, Keiichi3, Jinzaki, Masahiro1 jinzaki@rad.med.keio.ac.jp
Source: European Radiology. May2017, Vol. 27 Issue 5, p1963-1970. 8p. 2 Color Photographs, 1 Diagram, 5 Charts.
Subjects: Multidetector computed tomography, Contrast media, Sensitivity & specificity (Statistics), Aortic valve, Angiography
Abstract: Objectives: To evaluate the effectiveness of CT before TAVI using variable helical pitch (VHP) scanning and its diagnostic performance for coronary artery disease (CAD).Methods: Sixty patients (84.4 ± 4.6 years) scheduled for TAVI underwent CT using VHP scanning with the contrast material (CM) volume calculated as scanning time × weight [kg] × 0.06 mL. Retrospective electrocardiography (ECG)-gated scanning was utilized to examine the thorax, and non-ECG-gated scanning of the abdomen immediately followed. We analyzed CT attenuation values of the coronary arteries, aorta, iliac and femoral arteries. The coronary CT angiography images were evaluated for the presence of stenosis (≥50 %); invasive coronary angiography served as a reference standard.Results: The average attenuations of all of the arteries were greater than 400 HU. We could evaluate the peripheral access vessels and dimensions of the ascending aorta, aortic root, and aortic annulus in all patients. The average volume of CM was 38.7 ± 8.5 mL. On per-patient and vessel analysis, CT showed 91.7 % and 89.5 % sensitivity, and 91.3 % and 97.4 % negative predictive value (NPV).Conclusions: CT using VHP scanning with an average CM volume of 38.7 mL is useful before TAVI and had a high sensitivity and NPV in excluding obstructive CAD.Key Points: • TAVI-planning CT using variable helical pitch (VHP) scanning is useful. • The average volume of contrast material was 38.7 ± 8.5 mL. • The average attenuations of all the arteries were >400 HU. • This CT had a high sensitivity and NPV for excluding obstructive CAD. [ABSTRACT FROM AUTHOR]
Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Description
Abstract:<bold>Objectives: </bold>To evaluate the effectiveness of CT before TAVI using variable helical pitch (VHP) scanning and its diagnostic performance for coronary artery disease (CAD).<bold>Methods: </bold>Sixty patients (84.4 ± 4.6 years) scheduled for TAVI underwent CT using VHP scanning with the contrast material (CM) volume calculated as scanning time × weight [kg] × 0.06 mL. Retrospective electrocardiography (ECG)-gated scanning was utilized to examine the thorax, and non-ECG-gated scanning of the abdomen immediately followed. We analyzed CT attenuation values of the coronary arteries, aorta, iliac and femoral arteries. The coronary CT angiography images were evaluated for the presence of stenosis (≥50 %); invasive coronary angiography served as a reference standard.<bold>Results: </bold>The average attenuations of all of the arteries were greater than 400 HU. We could evaluate the peripheral access vessels and dimensions of the ascending aorta, aortic root, and aortic annulus in all patients. The average volume of CM was 38.7 ± 8.5 mL. On per-patient and vessel analysis, CT showed 91.7 % and 89.5 % sensitivity, and 91.3 % and 97.4 % negative predictive value (NPV).<bold>Conclusions: </bold>CT using VHP scanning with an average CM volume of 38.7 mL is useful before TAVI and had a high sensitivity and NPV in excluding obstructive CAD.<bold>Key Points: </bold>• TAVI-planning CT using variable helical pitch (VHP) scanning is useful. • The average volume of contrast material was 38.7 ± 8.5 mL. • The average attenuations of all the arteries were >400 HU. • This CT had a high sensitivity and NPV for excluding obstructive CAD. [ABSTRACT FROM AUTHOR]
ISSN:09387994
DOI:10.1007/s00330-016-4547-4