Subharmonic-Aided Pressure Estimation for Monitoring Interstitial Fluid Pressure in Tumors: Calibration and Treatment with Paclitaxel in Breast Cancer Xenografts.
Saved in:
| Title: | Subharmonic-Aided Pressure Estimation for Monitoring Interstitial Fluid Pressure in Tumors: Calibration and Treatment with Paclitaxel in Breast Cancer Xenografts. |
|---|---|
| Authors: | Halldorsdottir, Valgerdur G.1,2, Dave, Jaydev K.1, Marshall, Andrew1,2, Forsberg, Anya I.3, Fox, Traci B.4, Eisenbrey, John R.1, Machado, Priscilla1, Liu, Ji-Bin1, Merton, Daniel A.1, Forsberg, Flemming1 flemming.forsberg@jefferson.edu |
| Source: | Ultrasound in Medicine & Biology. Jul2017, Vol. 43 Issue 7, p1401-1410. 10p. |
| Subjects: | Breast cancer treatment, Fluid pressure, Paclitaxel, Calibration, Xenografts, Manometers, Animal experimentation, Antineoplastic agents, Breast tumors, Cell lines, Diagnostic imaging, Drug monitoring, Computers in medicine, Extracellular fluid, Pressure, Rats, Research evaluation, Research funding, Ultrasonic imaging, Treatment effectiveness, Physiology, Equipment & supplies |
| Abstract: | Interstitial fluid pressure (IFP) in rats with breast cancer xenografts was non-invasively estimated using subharmonic-aided pressure estimation (SHAPE) versus an invasive pressure monitor. Moreover, monitoring of IFP changes after chemotherapy was assessed. Eighty-nine rats (calibration n = 25, treatment n = 64) were injected with 5 × 106 breast cancer cells (MDA-MB-231). Radiofrequency signals were acquired (39 rats successfully imaged) with a Sonix RP scanner (BK Ultrasound, Richmond, BC, Canada) using a linear array (L9-4, transmit/receive: 8/4 MHz) after administration of Definity (Lantheus Medical Imaging, North Billerica, MA, USA; 180 μL/kg) and compared with readings from an invasive pressure monitor (Stryker, Berkshire, UK). An inverse linear relationship was established between tumor IFP and SHAPE (y = -1.06x + 28.27, r = -0.69, p = 0.01) in the calibration group. Use of this relationship in the treatment group resulted in r = 0.74 (p < 0.05) between measured (pressure monitor) and SHAPE-estimated IFP (average error: 6.24 mmHg). No significant before/after differences were observed with respect to paclitaxel treatment (5 mg/kg, Mayne Pharma, Paramus, NJ, USA) with either method (p ≥ 0.15). [ABSTRACT FROM AUTHOR] |
| Copyright of Ultrasound in Medicine & Biology is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
| FullText | Text: Availability: 0 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 123133311 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Subharmonic-Aided Pressure Estimation for Monitoring Interstitial Fluid Pressure in Tumors: Calibration and Treatment with Paclitaxel in Breast Cancer Xenografts. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Halldorsdottir%2C+Valgerdur+G%2E%22">Halldorsdottir, Valgerdur G.</searchLink><relatesTo>1,2</relatesTo><br /><searchLink fieldCode="AR" term="%22Dave%2C+Jaydev+K%2E%22">Dave, Jaydev K.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Marshall%2C+Andrew%22">Marshall, Andrew</searchLink><relatesTo>1,2</relatesTo><br /><searchLink fieldCode="AR" term="%22Forsberg%2C+Anya+I%2E%22">Forsberg, Anya I.</searchLink><relatesTo>3</relatesTo><br /><searchLink fieldCode="AR" term="%22Fox%2C+Traci+B%2E%22">Fox, Traci B.</searchLink><relatesTo>4</relatesTo><br /><searchLink fieldCode="AR" term="%22Eisenbrey%2C+John+R%2E%22">Eisenbrey, John R.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Machado%2C+Priscilla%22">Machado, Priscilla</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Liu%2C+Ji-Bin%22">Liu, Ji-Bin</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Merton%2C+Daniel+A%2E%22">Merton, Daniel A.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Forsberg%2C+Flemming%22">Forsberg, Flemming</searchLink><relatesTo>1</relatesTo><i> flemming.forsberg@jefferson.edu</i> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Ultrasound+in+Medicine+%26+Biology%22">Ultrasound in Medicine & Biology</searchLink>. Jul2017, Vol. 43 Issue 7, p1401-1410. 10p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Breast+cancer+treatment%22">Breast cancer treatment</searchLink><br /><searchLink fieldCode="DE" term="%22Fluid+pressure%22">Fluid pressure</searchLink><br /><searchLink fieldCode="DE" term="%22Paclitaxel%22">Paclitaxel</searchLink><br /><searchLink fieldCode="DE" term="%22Calibration%22">Calibration</searchLink><br /><searchLink fieldCode="DE" term="%22Xenografts%22">Xenografts</searchLink><br /><searchLink fieldCode="DE" term="%22Manometers%22">Manometers</searchLink><br /><searchLink fieldCode="DE" term="%22Animal+experimentation%22">Animal experimentation</searchLink><br /><searchLink fieldCode="DE" term="%22Antineoplastic+agents%22">Antineoplastic agents</searchLink><br /><searchLink fieldCode="DE" term="%22Breast+tumors%22">Breast tumors</searchLink><br /><searchLink fieldCode="DE" term="%22Cell+lines%22">Cell lines</searchLink><br /><searchLink fieldCode="DE" term="%22Diagnostic+imaging%22">Diagnostic imaging</searchLink><br /><searchLink fieldCode="DE" term="%22Drug+monitoring%22">Drug monitoring</searchLink><br /><searchLink fieldCode="DE" term="%22Computers+in+medicine%22">Computers in medicine</searchLink><br /><searchLink fieldCode="DE" term="%22Extracellular+fluid%22">Extracellular fluid</searchLink><br /><searchLink fieldCode="DE" term="%22Pressure%22">Pressure</searchLink><br /><searchLink fieldCode="DE" term="%22Rats%22">Rats</searchLink><br /><searchLink fieldCode="DE" term="%22Research+evaluation%22">Research evaluation</searchLink><br /><searchLink fieldCode="DE" term="%22Research+funding%22">Research funding</searchLink><br /><searchLink fieldCode="DE" term="%22Ultrasonic+imaging%22">Ultrasonic imaging</searchLink><br /><searchLink fieldCode="DE" term="%22Treatment+effectiveness%22">Treatment effectiveness</searchLink><br /><searchLink fieldCode="DE" term="%22Physiology%22">Physiology</searchLink><br /><searchLink fieldCode="DE" term="%22Equipment+%26+supplies%22">Equipment & supplies</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: Interstitial fluid pressure (IFP) in rats with breast cancer xenografts was non-invasively estimated using subharmonic-aided pressure estimation (SHAPE) versus an invasive pressure monitor. Moreover, monitoring of IFP changes after chemotherapy was assessed. Eighty-nine rats (calibration n = 25, treatment n = 64) were injected with 5 × 106 breast cancer cells (MDA-MB-231). Radiofrequency signals were acquired (39 rats successfully imaged) with a Sonix RP scanner (BK Ultrasound, Richmond, BC, Canada) using a linear array (L9-4, transmit/receive: 8/4 MHz) after administration of Definity (Lantheus Medical Imaging, North Billerica, MA, USA; 180 μL/kg) and compared with readings from an invasive pressure monitor (Stryker, Berkshire, UK). An inverse linear relationship was established between tumor IFP and SHAPE (y = -1.06x + 28.27, r = -0.69, p = 0.01) in the calibration group. Use of this relationship in the treatment group resulted in r = 0.74 (p < 0.05) between measured (pressure monitor) and SHAPE-estimated IFP (average error: 6.24 mmHg). No significant before/after differences were observed with respect to paclitaxel treatment (5 mg/kg, Mayne Pharma, Paramus, NJ, USA) with either method (p ≥ 0.15). [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Ultrasound in Medicine & Biology is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=123133311 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1016/j.ultrasmedbio.2017.02.011 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 10 StartPage: 1401 Subjects: – SubjectFull: Breast cancer treatment Type: general – SubjectFull: Fluid pressure Type: general – SubjectFull: Paclitaxel Type: general – SubjectFull: Calibration Type: general – SubjectFull: Xenografts Type: general – SubjectFull: Manometers Type: general – SubjectFull: Animal experimentation Type: general – SubjectFull: Antineoplastic agents Type: general – SubjectFull: Breast tumors Type: general – SubjectFull: Cell lines Type: general – SubjectFull: Diagnostic imaging Type: general – SubjectFull: Drug monitoring Type: general – SubjectFull: Computers in medicine Type: general – SubjectFull: Extracellular fluid Type: general – SubjectFull: Pressure Type: general – SubjectFull: Rats Type: general – SubjectFull: Research evaluation Type: general – SubjectFull: Research funding Type: general – SubjectFull: Ultrasonic imaging Type: general – SubjectFull: Treatment effectiveness Type: general – SubjectFull: Physiology Type: general – SubjectFull: Equipment & supplies Type: general Titles: – TitleFull: Subharmonic-Aided Pressure Estimation for Monitoring Interstitial Fluid Pressure in Tumors: Calibration and Treatment with Paclitaxel in Breast Cancer Xenografts. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Halldorsdottir, Valgerdur G. – PersonEntity: Name: NameFull: Dave, Jaydev K. – PersonEntity: Name: NameFull: Marshall, Andrew – PersonEntity: Name: NameFull: Forsberg, Anya I. – PersonEntity: Name: NameFull: Fox, Traci B. – PersonEntity: Name: NameFull: Eisenbrey, John R. – PersonEntity: Name: NameFull: Machado, Priscilla – PersonEntity: Name: NameFull: Liu, Ji-Bin – PersonEntity: Name: NameFull: Merton, Daniel A. – PersonEntity: Name: NameFull: Forsberg, Flemming IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 07 Text: Jul2017 Type: published Y: 2017 Identifiers: – Type: issn-print Value: 03015629 Numbering: – Type: volume Value: 43 – Type: issue Value: 7 Titles: – TitleFull: Ultrasound in Medicine & Biology Type: main |
| ResultId | 1 |