A multichannel block-matching denoising algorithm for spectral photon-counting CT images.

Saved in:
Bibliographic Details
Title: A multichannel block-matching denoising algorithm for spectral photon-counting CT images.
Authors: Harrison, Adam P.1, Xu, Ziyue1 ziyue.xu@gmail.com, Pourmorteza, Amir2, Bluemke, David A.2, Mollura, Daniel J.1
Source: Medical Physics. Jun2017, Vol. 44 Issue 6, p2447-2452. 6p.
Subjects: Photon counting, Photometry, Computed tomography, Radiotherapy, Electrotherapeutics
Abstract: Purpose We present a denoising algorithm designed for a whole-body prototype photon-counting computed tomography ( PCCT) scanner with up to 4 energy thresholds and associated energy-binned images. Methods Spectral PCCT images can exhibit low signal to noise ratios ( SNRs) due to the limited photon counts in each simultaneously-acquired energy bin. To help address this, our denoising method exploits the correlation and exact alignment between energy bins, adapting the highly-effective block-matching 3D ( BM3D) denoising algorithm for PCCT. The original single-channel BM3D algorithm operates patch-by-patch. For each small patch in the image, a patch grouping action collects similar patches from the rest of the image, which are then collaboratively filtered together. The resulting performance hinges on accurate patch grouping. Our improved multi-channel version, called BM3D_ PCCT, incorporates two improvements. First, BM3D_ PCCT uses a more accurate shared patch grouping based on the image reconstructed from photons detected in all 4 energy bins. Second, BM3D_ PCCT performs a cross-channel decorrelation, adding a further dimension to the collaborative filtering process. These two improvements produce a more effective algorithm for PCCT denoising. Results Preliminary results compare BM3D_ PCCT against BM3D_Naive, which denoises each energy bin independently. Experiments use a three-contrast PCCT image of a canine abdomen. Within five regions of interest, selected from paraspinal muscle, liver, and visceral fat, BM3D_ PCCT reduces the noise standard deviation by 65.0%, compared to 40.4% for BM3D_Naive. Attenuation values of the contrast agents in calibration vials also cluster much tighter to their respective lines of best fit. Mean angular differences (in degrees) for the original, BM3D_Naive, and BM3D_ PCCT images, respectively, were 15.61, 7.34, and 4.45 (iodine); 12.17, 7.17, and 4.39 (galodinium); and 12.86, 6.33, and 3.96 (bismuth). Conclusion We outline a multi-channel denoising algorithm tailored for spectral PCCT images, demonstrating improved performance over an independent, yet state-of-the-art, single-channel approach. [ABSTRACT FROM AUTHOR]
Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: egs
DbLabel: Engineering Source
An: 123589243
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: A multichannel block-matching denoising algorithm for spectral photon-counting CT images.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Harrison%2C+Adam+P%2E%22">Harrison, Adam P.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Xu%2C+Ziyue%22">Xu, Ziyue</searchLink><relatesTo>1</relatesTo><i> ziyue.xu@gmail.com</i><br /><searchLink fieldCode="AR" term="%22Pourmorteza%2C+Amir%22">Pourmorteza, Amir</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Bluemke%2C+David+A%2E%22">Bluemke, David A.</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Mollura%2C+Daniel+J%2E%22">Mollura, Daniel J.</searchLink><relatesTo>1</relatesTo>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Medical+Physics%22">Medical Physics</searchLink>. Jun2017, Vol. 44 Issue 6, p2447-2452. 6p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Photon+counting%22">Photon counting</searchLink><br /><searchLink fieldCode="DE" term="%22Photometry%22">Photometry</searchLink><br /><searchLink fieldCode="DE" term="%22Computed+tomography%22">Computed tomography</searchLink><br /><searchLink fieldCode="DE" term="%22Radiotherapy%22">Radiotherapy</searchLink><br /><searchLink fieldCode="DE" term="%22Electrotherapeutics%22">Electrotherapeutics</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Purpose We present a denoising algorithm designed for a whole-body prototype photon-counting computed tomography ( PCCT) scanner with up to 4 energy thresholds and associated energy-binned images. Methods Spectral PCCT images can exhibit low signal to noise ratios ( SNRs) due to the limited photon counts in each simultaneously-acquired energy bin. To help address this, our denoising method exploits the correlation and exact alignment between energy bins, adapting the highly-effective block-matching 3D ( BM3D) denoising algorithm for PCCT. The original single-channel BM3D algorithm operates patch-by-patch. For each small patch in the image, a patch grouping action collects similar patches from the rest of the image, which are then collaboratively filtered together. The resulting performance hinges on accurate patch grouping. Our improved multi-channel version, called BM3D_ PCCT, incorporates two improvements. First, BM3D_ PCCT uses a more accurate shared patch grouping based on the image reconstructed from photons detected in all 4 energy bins. Second, BM3D_ PCCT performs a cross-channel decorrelation, adding a further dimension to the collaborative filtering process. These two improvements produce a more effective algorithm for PCCT denoising. Results Preliminary results compare BM3D_ PCCT against BM3D_Naive, which denoises each energy bin independently. Experiments use a three-contrast PCCT image of a canine abdomen. Within five regions of interest, selected from paraspinal muscle, liver, and visceral fat, BM3D_ PCCT reduces the noise standard deviation by 65.0%, compared to 40.4% for BM3D_Naive. Attenuation values of the contrast agents in calibration vials also cluster much tighter to their respective lines of best fit. Mean angular differences (in degrees) for the original, BM3D_Naive, and BM3D_ PCCT images, respectively, were 15.61, 7.34, and 4.45 (iodine); 12.17, 7.17, and 4.39 (galodinium); and 12.86, 6.33, and 3.96 (bismuth). Conclusion We outline a multi-channel denoising algorithm tailored for spectral PCCT images, demonstrating improved performance over an independent, yet state-of-the-art, single-channel approach. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=123589243
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1002/mp.12225
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 6
        StartPage: 2447
    Subjects:
      – SubjectFull: Photon counting
        Type: general
      – SubjectFull: Photometry
        Type: general
      – SubjectFull: Computed tomography
        Type: general
      – SubjectFull: Radiotherapy
        Type: general
      – SubjectFull: Electrotherapeutics
        Type: general
    Titles:
      – TitleFull: A multichannel block-matching denoising algorithm for spectral photon-counting CT images.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Harrison, Adam P.
      – PersonEntity:
          Name:
            NameFull: Xu, Ziyue
      – PersonEntity:
          Name:
            NameFull: Pourmorteza, Amir
      – PersonEntity:
          Name:
            NameFull: Bluemke, David A.
      – PersonEntity:
          Name:
            NameFull: Mollura, Daniel J.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 06
              Text: Jun2017
              Type: published
              Y: 2017
          Identifiers:
            – Type: issn-print
              Value: 00942405
          Numbering:
            – Type: volume
              Value: 44
            – Type: issue
              Value: 6
          Titles:
            – TitleFull: Medical Physics
              Type: main
ResultId 1