Data‐driven optimal binning for respiratory motion management in PET.

Saved in:
Bibliographic Details
Title: Data‐driven optimal binning for respiratory motion management in PET.
Authors: Kesner, Adam L.1 kesnera@mskcc.org, Meier, Joseph G.2, Burckhardt, Darrell D.3, Schwartz, Jazmin1, Lynch, David A.4
Source: Medical Physics. Jan2018, Vol. 45 Issue 1, p277-286. 10p.
Subjects: Respiratory organ physiology, Positron emission tomography, Parameters (Statistics), Medical protocols, Fluorodeoxyglucose F18
Abstract: Purpose: Respiratory gating has been used in PET imaging to reduce the amount of image blurring caused by patient motion. Optimal binning is an approach for using the motion‐characterized data by binning it into a single, easy to understand/use, optimal bin. To date, optimal binning protocols have utilized externally driven motion characterization strategies that have been tuned with population‐derived assumptions and parameters. In this work, we are proposing a new strategy with which to characterize motion directly from a patient's gated scan, and use that signal to create a patient/instance‐specific optimal bin image. Methods: Two hundred and nineteen phase‐gated FDG PET scans, acquired using data‐driven gating as described previously, were used as the input for this study. For each scan, a phase‐amplitude motion characterization was generated and normalized using principle component analysis. A patient‐specific “optimal bin” window was derived using this characterization, via methods that mirror traditional optimal window binning strategies. The resulting optimal bin images were validated by correlating quantitative and qualitative measurements in the population of PET scans. Results: In 53% (n = 115) of the image population, the optimal bin was determined to include 100% of the image statistics. In the remaining images, the optimal binning windows averaged 60% of the statistics and ranged between 20% and 90%. Tuning the algorithm, through a single acceptance window parameter, allowed for adjustments of the algorithm's performance in the population toward conservation of motion or reduced noise—enabling users to incorporate their definition of optimal. In the population of images that were deemed appropriate for segregation, average lesion SUV max were 7.9, 8.5, and 9.0 for nongated images, optimal bin, and gated images, respectively. The Pearson correlation of FWHM measurements between optimal bin images and gated images were better than with nongated images, 0.89 and 0.85, respectively. Generally, optimal bin images had better resolution than the nongated images and better noise characteristics than the gated images. Discussion: We extended the concept of optimal binning to a data‐driven form, updating a traditionally one‐size‐fits‐all approach to a conformal one that supports adaptive imaging. This automated strategy was implemented easily within a large population and encapsulated motion information in an easy to use 3D image. Its simplicity and practicality may make this, or similar approaches ideal for use in clinical settings. [ABSTRACT FROM AUTHOR]
Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: egs
DbLabel: Engineering Source
An: 127273249
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Data‐driven optimal binning for respiratory motion management in PET.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Kesner%2C+Adam+L%2E%22">Kesner, Adam L.</searchLink><relatesTo>1</relatesTo><i> kesnera@mskcc.org</i><br /><searchLink fieldCode="AR" term="%22Meier%2C+Joseph+G%2E%22">Meier, Joseph G.</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Burckhardt%2C+Darrell+D%2E%22">Burckhardt, Darrell D.</searchLink><relatesTo>3</relatesTo><br /><searchLink fieldCode="AR" term="%22Schwartz%2C+Jazmin%22">Schwartz, Jazmin</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Lynch%2C+David+A%2E%22">Lynch, David A.</searchLink><relatesTo>4</relatesTo>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Medical+Physics%22">Medical Physics</searchLink>. Jan2018, Vol. 45 Issue 1, p277-286. 10p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Respiratory+organ+physiology%22">Respiratory organ physiology</searchLink><br /><searchLink fieldCode="DE" term="%22Positron+emission+tomography%22">Positron emission tomography</searchLink><br /><searchLink fieldCode="DE" term="%22Parameters+%28Statistics%29%22">Parameters (Statistics)</searchLink><br /><searchLink fieldCode="DE" term="%22Medical+protocols%22">Medical protocols</searchLink><br /><searchLink fieldCode="DE" term="%22Fluorodeoxyglucose+F18%22">Fluorodeoxyglucose F18</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Purpose: Respiratory gating has been used in PET imaging to reduce the amount of image blurring caused by patient motion. Optimal binning is an approach for using the motion‐characterized data by binning it into a single, easy to understand/use, optimal bin. To date, optimal binning protocols have utilized externally driven motion characterization strategies that have been tuned with population‐derived assumptions and parameters. In this work, we are proposing a new strategy with which to characterize motion directly from a patient's gated scan, and use that signal to create a patient/instance‐specific optimal bin image. Methods: Two hundred and nineteen phase‐gated FDG PET scans, acquired using data‐driven gating as described previously, were used as the input for this study. For each scan, a phase‐amplitude motion characterization was generated and normalized using principle component analysis. A patient‐specific “optimal bin” window was derived using this characterization, via methods that mirror traditional optimal window binning strategies. The resulting optimal bin images were validated by correlating quantitative and qualitative measurements in the population of PET scans. Results: In 53% (n = 115) of the image population, the optimal bin was determined to include 100% of the image statistics. In the remaining images, the optimal binning windows averaged 60% of the statistics and ranged between 20% and 90%. Tuning the algorithm, through a single acceptance window parameter, allowed for adjustments of the algorithm's performance in the population toward conservation of motion or reduced noise—enabling users to incorporate their definition of optimal. In the population of images that were deemed appropriate for segregation, average lesion SUV max were 7.9, 8.5, and 9.0 for nongated images, optimal bin, and gated images, respectively. The Pearson correlation of FWHM measurements between optimal bin images and gated images were better than with nongated images, 0.89 and 0.85, respectively. Generally, optimal bin images had better resolution than the nongated images and better noise characteristics than the gated images. Discussion: We extended the concept of optimal binning to a data‐driven form, updating a traditionally one‐size‐fits‐all approach to a conformal one that supports adaptive imaging. This automated strategy was implemented easily within a large population and encapsulated motion information in an easy to use 3D image. Its simplicity and practicality may make this, or similar approaches ideal for use in clinical settings. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=127273249
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1002/mp.12651
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 10
        StartPage: 277
    Subjects:
      – SubjectFull: Respiratory organ physiology
        Type: general
      – SubjectFull: Positron emission tomography
        Type: general
      – SubjectFull: Parameters (Statistics)
        Type: general
      – SubjectFull: Medical protocols
        Type: general
      – SubjectFull: Fluorodeoxyglucose F18
        Type: general
    Titles:
      – TitleFull: Data‐driven optimal binning for respiratory motion management in PET.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Kesner, Adam L.
      – PersonEntity:
          Name:
            NameFull: Meier, Joseph G.
      – PersonEntity:
          Name:
            NameFull: Burckhardt, Darrell D.
      – PersonEntity:
          Name:
            NameFull: Schwartz, Jazmin
      – PersonEntity:
          Name:
            NameFull: Lynch, David A.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 01
              Text: Jan2018
              Type: published
              Y: 2018
          Identifiers:
            – Type: issn-print
              Value: 00942405
          Numbering:
            – Type: volume
              Value: 45
            – Type: issue
              Value: 1
          Titles:
            – TitleFull: Medical Physics
              Type: main
ResultId 1