Development of an advanced two‐dimensional microdosimetric detector based on THick Gas Electron Multipliers.

Saved in:
Bibliographic Details
Title: Development of an advanced two‐dimensional microdosimetric detector based on THick Gas Electron Multipliers.
Authors: Darvish‐Molla, Sahar1,2 darvis@mcmaster.ca, Prestwich, William V.1,2, Byun, Soo Hyun1,2
Source: Medical Physics. Mar2018, Vol. 45 Issue 3, p1241-1254. 14p.
Subjects: Photomultipliers, Microdosimetry, Electron counters, Microcontrollers, Ion accelerators
Abstract: Purpose: The THick Gas Electron Multiplier (THGEM)‐based tissue‐equivalent proportional counter (TEPC) has been proven to be useful for microdosimetry due to its flexibility in varying the gaseous sensitive volume and achieving high multiplication gain. Aiming at measuring the spatial distribution of radiation dose for mixed neutron‐gamma fields, an advanced two‐dimensional (2D) THGEM‐TEPC was designed and constructed at McMaster University which will enable us to overcome the operational limitation of the classical TEPCs, particularly for high‐dose rate fields. Compared to the traditional TEPCs, anode wire electrodes were replaced by a THGEM layer, which not only enhances the gas multiplication gain but also offers a flexible and convenient fabrication for building 2D detectors. Method & Materials: The 2D THGEM TEPC consists of an array of 3 × 3 sensitive volumes, equivalent to nine individual TEPCs, each of which has a dimension of 5 mm diameter and length. Taking the overall cost, size and flexibility into account, to process nine detector signals simultaneously, a multi‐input digital pulse processing system was developed by using modern microcontrollers, each of which is coupled with a 12‐bit sampling ADC. Results: Using the McMaster Tandetron 7Li(p,n) accelerator neutron source, both fundamental detector performance, as well as neutron dosimetric response of the 2D THGEM‐TEPC, has been extensively investigated and compared to the data acquired by a standard spherical TEPC. It was shown that the microdosimetric response and the measured absorbed dose rate of the 2D THGEM detector developed in this study are comparable to the standard 1/2” TEPC which is commercially available. Conclusion: This study proved that the 2D TEPC based on the THGEM technology can be effectively used in microdosimetry studies and is a promising detector for measuring the absorbed dose rate distribution over an area in mixed radiation fields. This unique small gas cavity detector opens new possibilities in applications for high‐intensity mixed radiation fields as well as in nanodosimetry. [ABSTRACT FROM AUTHOR]
Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: egs
DbLabel: Engineering Source
An: 128441203
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Development of an advanced two‐dimensional microdosimetric detector based on THick Gas Electron Multipliers.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Darvish‐Molla%2C+Sahar%22">Darvish‐Molla, Sahar</searchLink><relatesTo>1,2</relatesTo><i> darvis@mcmaster.ca</i><br /><searchLink fieldCode="AR" term="%22Prestwich%2C+William+V%2E%22">Prestwich, William V.</searchLink><relatesTo>1,2</relatesTo><br /><searchLink fieldCode="AR" term="%22Byun%2C+Soo+Hyun%22">Byun, Soo Hyun</searchLink><relatesTo>1,2</relatesTo>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Medical+Physics%22">Medical Physics</searchLink>. Mar2018, Vol. 45 Issue 3, p1241-1254. 14p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Photomultipliers%22">Photomultipliers</searchLink><br /><searchLink fieldCode="DE" term="%22Microdosimetry%22">Microdosimetry</searchLink><br /><searchLink fieldCode="DE" term="%22Electron+counters%22">Electron counters</searchLink><br /><searchLink fieldCode="DE" term="%22Microcontrollers%22">Microcontrollers</searchLink><br /><searchLink fieldCode="DE" term="%22Ion+accelerators%22">Ion accelerators</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Purpose: The THick Gas Electron Multiplier (THGEM)‐based tissue‐equivalent proportional counter (TEPC) has been proven to be useful for microdosimetry due to its flexibility in varying the gaseous sensitive volume and achieving high multiplication gain. Aiming at measuring the spatial distribution of radiation dose for mixed neutron‐gamma fields, an advanced two‐dimensional (2D) THGEM‐TEPC was designed and constructed at McMaster University which will enable us to overcome the operational limitation of the classical TEPCs, particularly for high‐dose rate fields. Compared to the traditional TEPCs, anode wire electrodes were replaced by a THGEM layer, which not only enhances the gas multiplication gain but also offers a flexible and convenient fabrication for building 2D detectors. Method & Materials: The 2D THGEM TEPC consists of an array of 3 × 3 sensitive volumes, equivalent to nine individual TEPCs, each of which has a dimension of 5 mm diameter and length. Taking the overall cost, size and flexibility into account, to process nine detector signals simultaneously, a multi‐input digital pulse processing system was developed by using modern microcontrollers, each of which is coupled with a 12‐bit sampling ADC. Results: Using the McMaster Tandetron 7Li(p,n) accelerator neutron source, both fundamental detector performance, as well as neutron dosimetric response of the 2D THGEM‐TEPC, has been extensively investigated and compared to the data acquired by a standard spherical TEPC. It was shown that the microdosimetric response and the measured absorbed dose rate of the 2D THGEM detector developed in this study are comparable to the standard 1/2” TEPC which is commercially available. Conclusion: This study proved that the 2D TEPC based on the THGEM technology can be effectively used in microdosimetry studies and is a promising detector for measuring the absorbed dose rate distribution over an area in mixed radiation fields. This unique small gas cavity detector opens new possibilities in applications for high‐intensity mixed radiation fields as well as in nanodosimetry. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=128441203
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1002/mp.12750
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 14
        StartPage: 1241
    Subjects:
      – SubjectFull: Photomultipliers
        Type: general
      – SubjectFull: Microdosimetry
        Type: general
      – SubjectFull: Electron counters
        Type: general
      – SubjectFull: Microcontrollers
        Type: general
      – SubjectFull: Ion accelerators
        Type: general
    Titles:
      – TitleFull: Development of an advanced two‐dimensional microdosimetric detector based on THick Gas Electron Multipliers.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Darvish‐Molla, Sahar
      – PersonEntity:
          Name:
            NameFull: Prestwich, William V.
      – PersonEntity:
          Name:
            NameFull: Byun, Soo Hyun
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 03
              Text: Mar2018
              Type: published
              Y: 2018
          Identifiers:
            – Type: issn-print
              Value: 00942405
          Numbering:
            – Type: volume
              Value: 45
            – Type: issue
              Value: 3
          Titles:
            – TitleFull: Medical Physics
              Type: main
ResultId 1