Diminished cerebral oxygen extraction and metabolic rate in sickle cell disease using T2 relaxation under spin tagging MRI.
Saved in:
| Title: | Diminished cerebral oxygen extraction and metabolic rate in sickle cell disease using T2 relaxation under spin tagging MRI. |
|---|---|
| Authors: | Bush, Adam M.1, Coates, Thomas D.2, Wood, John C.3 jwood@chla.usc.edu |
| Source: | Magnetic Resonance in Medicine. Jul2018, Vol. 80 Issue 1, p294-303. 10p. |
| Abstract: | Purpose: T2 MRI oximetry can noninvasively determine oxygen saturation (Y) but requires empirical MR calibration models to convert the measured blood transverse relaxation (T2b) into Y. The accuracy of existing T2b models in the presence of blood disorders such as sickle cell disease (SCD) remains unknown. Methods: A Carr Purcell Meiboom Gill T2 preparation sequence was used to make 83 whole blood measurements from 11 subjects with SCD to derive an ex vivo sickle hemoglobin (HbS) T2b model. Forearm venous blood gas, sagittal sinus T2 (T2 Relaxation Under Spin Tagging) and total brain blood flow (phase contrast MRI) were measured in 37 healthy controls and 33 SCD subjects (age 24.6 ± 10.2 years). Cerebral oxygen saturation, extraction fraction, and metabolic rate estimates were calculated using three separate T2b models. Cerebral and forearm oxygen extraction fraction were compared. Results: Ex vivo, SCD blood had greater saturation dependent relaxivity than control blood, with a weak dependence on HbS and no dependence on hematocrit. In vivo, the HbS T2b model predicted Yv values with lowest coefficient of variation (compared with existing T2b models) and the strongest correlation with peripheral venous oximetry (r2 = .29). The HbS T2b model predicted systematically higher Yv measurements in SCD patients (73 ± 5 and 61 ± 6; |
| Copyright of Magnetic Resonance in Medicine is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
|
Full text is not displayed to guests.
Login for full access.
|
|
| FullText | Links: – Type: pdflink Text: Availability: 1 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 128767115 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Diminished cerebral oxygen extraction and metabolic rate in sickle cell disease using T2 relaxation under spin tagging MRI. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Bush%2C+Adam+M%2E%22">Bush, Adam M.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Coates%2C+Thomas+D%2E%22">Coates, Thomas D.</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Wood%2C+John+C%2E%22">Wood, John C.</searchLink><relatesTo>3</relatesTo><i> jwood@chla.usc.edu</i> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Magnetic+Resonance+in+Medicine%22">Magnetic Resonance in Medicine</searchLink>. Jul2018, Vol. 80 Issue 1, p294-303. 10p. – Name: Abstract Label: Abstract Group: Ab Data: Purpose: T2 MRI oximetry can noninvasively determine oxygen saturation (Y) but requires empirical MR calibration models to convert the measured blood transverse relaxation (T2b) into Y. The accuracy of existing T2b models in the presence of blood disorders such as sickle cell disease (SCD) remains unknown. Methods: A Carr Purcell Meiboom Gill T2 preparation sequence was used to make 83 whole blood measurements from 11 subjects with SCD to derive an ex vivo sickle hemoglobin (HbS) T2b model. Forearm venous blood gas, sagittal sinus T2 (T2 Relaxation Under Spin Tagging) and total brain blood flow (phase contrast MRI) were measured in 37 healthy controls and 33 SCD subjects (age 24.6 ± 10.2 years). Cerebral oxygen saturation, extraction fraction, and metabolic rate estimates were calculated using three separate T2b models. Cerebral and forearm oxygen extraction fraction were compared. Results: Ex vivo, SCD blood had greater saturation dependent relaxivity than control blood, with a weak dependence on HbS and no dependence on hematocrit. In vivo, the HbS T2b model predicted Yv values with lowest coefficient of variation (compared with existing T2b models) and the strongest correlation with peripheral venous oximetry (r2 = .29). The HbS T2b model predicted systematically higher Yv measurements in SCD patients (73 ± 5 and 61 ± 6; <italic>P</italic> < 0.0001) which was mirrored by peripheral venous measurements (75 ± 20 and 45 ± 20; <italic>P</italic> < 0.0001). Conclusion: Cerebral and peripheral oxygen extraction are decreased in SCD patients, suggesting either blood flow is increased beyond metabolic demands or the presence of physiological arterial‐venous shunting. Magn Reson Med 80:294–303, 2018. © 2017 International Society for Magnetic Resonance in Medicine. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Magnetic Resonance in Medicine is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=128767115 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1002/mrm.27015 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 10 StartPage: 294 Titles: – TitleFull: Diminished cerebral oxygen extraction and metabolic rate in sickle cell disease using T2 relaxation under spin tagging MRI. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Bush, Adam M. – PersonEntity: Name: NameFull: Coates, Thomas D. – PersonEntity: Name: NameFull: Wood, John C. IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 07 Text: Jul2018 Type: published Y: 2018 Identifiers: – Type: issn-print Value: 07403194 Numbering: – Type: volume Value: 80 – Type: issue Value: 1 Titles: – TitleFull: Magnetic Resonance in Medicine Type: main |
| ResultId | 1 |