Metal artifact reduction MRI of total ankle arthroplasty implants.
Saved in:
| Title: | Metal artifact reduction MRI of total ankle arthroplasty implants. |
|---|---|
| Authors: | de Cesar Netto, Cesar1,2, Fonseca, Lucas F.1, Fritz, Benjamin3,4, Stern, Steven E.5, Raithel, Esther6, Nittka, Mathias6, Schon, Lew C.1, Fritz, Jan2 jfritz9@jhmi.edu |
| Source: | European Radiology. May2018, Vol. 28 Issue 5, p2216-2227. 12p. 5 Black and White Photographs, 1 Diagram, 5 Charts. |
| Subjects: | Magnetic resonance imaging, Fracture fixation, Orthopedic implants, Bone resorption, Diagnostic imaging |
| Abstract: | |
| Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
|
Full text is not displayed to guests.
Login for full access.
|
|
| Abstract: | <bold>Objectives: </bold>To assess high-bandwidth and compressed sensing-(CS)-SEMAC turbo spin echo (TSE) techniques for metal artifact reduction MRI of total ankle arthroplasty (TAA) implants.<bold>Methods: </bold>Following institutional approval and consent, 40 subjects with TAA implants underwent 1.5-T MRI prospectively. Evaluations included bone-implant interfaces, anatomical structures, abnormal findings and differential diagnoses before and after MRI. AUCs of P-P plots were used to determine superiority. Statistical differences were evaluated with McNemar and chi-square tests. P-values ≤ 0.05 were considered significant.<bold>Results: </bold>CS-SEMAC TSE was superior to high-bandwidth TSE in showing the bone-implant interfaces (AUC=0.917), periprosthetic bone, tendons and joint capsule (AUC=0.337-0.766), bone marrow oedema (43 % difference, p=0.041), interface osteolysis (63 %, p=0.015), tendinopathy (62 %, p=0.062), periprosthetic fractures (60 %, p=0.250), synovitis (43 %, p=0.250), as well as reader confidence for bone marrow oedema (p=<0.001), fracture (p=0.001), interface osteolysis (p=0.003), synovitis (p=0.027) and tendinopathy (p=0.034). The number of differential diagnoses in symptomatic subjects after the MRI with CS-SEMAC decreased from 3 (1-4) to 1 (1-2) (p<0.001).<bold>Conclusions: </bold>MRI of TAA implants with CS-SEMAC improves the diagnosis of interface osteolysis, periprosthetic bone marrow oedema, fractures and tendinopathy when compared to high-BW TSE, and has a positive effect on patient management.<bold>Key Points: </bold>• High-bandwidth TSE and compressed sensing SEMAC improve MRI of ankle arthroplasty implants. • Compressed sensing SEMAC improves bone-implant interfaces, periprosthetic bone, tendons and joint capsule visibility. • Compressed sensing SEMAC improves the diagnosis of osteolysis, tendinopathy, fractures and synovitis. • MRI decreases the number of clinical differential diagnoses of painful ankle arthroplasty implants. [ABSTRACT FROM AUTHOR] |
|---|---|
| ISSN: | 09387994 |
| DOI: | 10.1007/s00330-017-5153-9 |