Acuros CTS: A fast, linear Boltzmann transport equation solver for computed tomography scatter – Part I: Core algorithms and validation.

Saved in:
Bibliographic Details
Title: Acuros CTS: A fast, linear Boltzmann transport equation solver for computed tomography scatter – Part I: Core algorithms and validation.
Authors: Maslowski, Alexander1, Wang, Adam1 adam.wang@varian.com, Sun, Mingshan1, Wareing, Todd1, Davis, Ian1, Star‐Lack, Josh1
Source: Medical Physics. May2018, Vol. 45 Issue 5, p1899-1913. 15p.
Subjects: Boltzmann's equation, Computed tomography, Photon transport theory, Ray tracing, Finite element method
Abstract: Purpose: To describe Acuros® CTS, a new software tool for rapidly and accurately estimating scatter in x‐ray projection images by deterministically solving the linear Boltzmann transport equation (LBTE). Methods: The LBTE describes the behavior of particles as they interact with an object across spatial, energy, and directional (propagation) domains. Acuros CTS deterministically solves the LBTE by modeling photon transport associated with an x‐ray projection in three main steps: (a) Ray tracing photons from the x‐ray source into the object where they experience their first scattering event and form scattering sources. (b) Propagating photons from their first scattering sources across the object in all directions to form second scattering sources, then repeating this process until all high‐order scattering sources are computed using the source iteration method. (c) Ray‐tracing photons from scattering sources within the object to the detector, accounting for the detector's energy and anti‐scatter grid responses. To make this process computationally tractable, a combination of analytical and discrete methods is applied. The three domains are discretized using the Linear Discontinuous Finite Elements, Multigroup, and Discrete Ordinates methods, respectively, which confer the ability to maintain the accuracy of a continuous solution. Furthermore, through the implementation in CUDA, we sought to exploit the parallel computing capabilities of graphics processing units (GPUs) to achieve the speeds required for clinical utilization. Acuros CTS was validated against Geant4 Monte Carlo simulations using two digital phantoms: (a) a water phantom containing lung, air, and bone inserts (WLAB phantom) and (b) a pelvis phantom derived from a clinical CT dataset. For these studies, we modeled the TrueBeam® (Varian Medical Systems, Palo Alto, CA) kV imaging system with a source energy of 125 kVp. The imager comprised a 600 μm‐thick Cesium Iodide (CsI) scintillator and a 10:1 one‐dimensional anti‐scatter grid. For the WLAB studies, the full‐fan geometry without a bowtie filter was used (with and without the anti‐scatter grid). For the pelvis phantom studies, a half‐fan geometry with bowtie was used (with the anti‐scatter grid). Scattered and primary photon fluences and energies deposited in the detector were recorded. Results: The Acuros CTS and Monte Carlo results demonstrated excellent agreement. For the WLAB studies, the average percent difference between the Monte Carlo‐ and Acuros‐generated scattered photon fluences at the face of the detector was −0.7%. After including the detector response, the average percent differences between the Monte Carlo‐ and Acuros‐generated scatter fractions (SF) were −0.1% without the grid and 0.6% with the grid. For the digital pelvis simulation, the Monte Carlo‐ and Acuros‐generated SFs agreed to within 0.1% on average, despite the scatter‐to‐primary ratios (SPRs) being as high as 5.5. The Acuros CTS computation time for each scatter image was ~1 s using a single GPU. Conclusions: Acuros CTS enables a fast and accurate calculation of scatter images by deterministically solving the LBTE thus offering a computationally attractive alternative to Monte Carlo methods. Part II describes the application of Acuros CTS to scatter correction of CBCT scans on the TrueBeam system. [ABSTRACT FROM AUTHOR]
Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: egs
DbLabel: Engineering Source
An: 129573864
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Acuros CTS: A fast, linear Boltzmann transport equation solver for computed tomography scatter – Part I: Core algorithms and validation.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Maslowski%2C+Alexander%22">Maslowski, Alexander</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Wang%2C+Adam%22">Wang, Adam</searchLink><relatesTo>1</relatesTo><i> adam.wang@varian.com</i><br /><searchLink fieldCode="AR" term="%22Sun%2C+Mingshan%22">Sun, Mingshan</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Wareing%2C+Todd%22">Wareing, Todd</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Davis%2C+Ian%22">Davis, Ian</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Star‐Lack%2C+Josh%22">Star‐Lack, Josh</searchLink><relatesTo>1</relatesTo>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Medical+Physics%22">Medical Physics</searchLink>. May2018, Vol. 45 Issue 5, p1899-1913. 15p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Boltzmann's+equation%22">Boltzmann's equation</searchLink><br /><searchLink fieldCode="DE" term="%22Computed+tomography%22">Computed tomography</searchLink><br /><searchLink fieldCode="DE" term="%22Photon+transport+theory%22">Photon transport theory</searchLink><br /><searchLink fieldCode="DE" term="%22Ray+tracing%22">Ray tracing</searchLink><br /><searchLink fieldCode="DE" term="%22Finite+element+method%22">Finite element method</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Purpose: To describe Acuros® CTS, a new software tool for rapidly and accurately estimating scatter in x‐ray projection images by deterministically solving the linear Boltzmann transport equation (LBTE). Methods: The LBTE describes the behavior of particles as they interact with an object across spatial, energy, and directional (propagation) domains. Acuros CTS deterministically solves the LBTE by modeling photon transport associated with an x‐ray projection in three main steps: (a) Ray tracing photons from the x‐ray source into the object where they experience their first scattering event and form scattering sources. (b) Propagating photons from their first scattering sources across the object in all directions to form second scattering sources, then repeating this process until all high‐order scattering sources are computed using the source iteration method. (c) Ray‐tracing photons from scattering sources within the object to the detector, accounting for the detector's energy and anti‐scatter grid responses. To make this process computationally tractable, a combination of analytical and discrete methods is applied. The three domains are discretized using the Linear Discontinuous Finite Elements, Multigroup, and Discrete Ordinates methods, respectively, which confer the ability to maintain the accuracy of a continuous solution. Furthermore, through the implementation in CUDA, we sought to exploit the parallel computing capabilities of graphics processing units (GPUs) to achieve the speeds required for clinical utilization. Acuros CTS was validated against Geant4 Monte Carlo simulations using two digital phantoms: (a) a water phantom containing lung, air, and bone inserts (WLAB phantom) and (b) a pelvis phantom derived from a clinical CT dataset. For these studies, we modeled the TrueBeam® (Varian Medical Systems, Palo Alto, CA) kV imaging system with a source energy of 125 kVp. The imager comprised a 600 <italic>μ</italic>m‐thick Cesium Iodide (CsI) scintillator and a 10:1 one‐dimensional anti‐scatter grid. For the WLAB studies, the full‐fan geometry without a bowtie filter was used (with and without the anti‐scatter grid). For the pelvis phantom studies, a half‐fan geometry with bowtie was used (with the anti‐scatter grid). Scattered and primary photon fluences and energies deposited in the detector were recorded. Results: The Acuros CTS and Monte Carlo results demonstrated excellent agreement. For the WLAB studies, the average percent difference between the Monte Carlo‐ and Acuros‐generated scattered photon fluences at the face of the detector was −0.7%. After including the detector response, the average percent differences between the Monte Carlo‐ and Acuros‐generated scatter fractions (SF) were −0.1% without the grid and 0.6% with the grid. For the digital pelvis simulation, the Monte Carlo‐ and Acuros‐generated SFs agreed to within 0.1% on average, despite the scatter‐to‐primary ratios (SPRs) being as high as 5.5. The Acuros CTS computation time for each scatter image was ~1 s using a single GPU. Conclusions: Acuros CTS enables a fast and accurate calculation of scatter images by deterministically solving the LBTE thus offering a computationally attractive alternative to Monte Carlo methods. Part II describes the application of Acuros CTS to scatter correction of CBCT scans on the TrueBeam system. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=129573864
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1002/mp.12850
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 15
        StartPage: 1899
    Subjects:
      – SubjectFull: Boltzmann's equation
        Type: general
      – SubjectFull: Computed tomography
        Type: general
      – SubjectFull: Photon transport theory
        Type: general
      – SubjectFull: Ray tracing
        Type: general
      – SubjectFull: Finite element method
        Type: general
    Titles:
      – TitleFull: Acuros CTS: A fast, linear Boltzmann transport equation solver for computed tomography scatter – Part I: Core algorithms and validation.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Maslowski, Alexander
      – PersonEntity:
          Name:
            NameFull: Wang, Adam
      – PersonEntity:
          Name:
            NameFull: Sun, Mingshan
      – PersonEntity:
          Name:
            NameFull: Wareing, Todd
      – PersonEntity:
          Name:
            NameFull: Davis, Ian
      – PersonEntity:
          Name:
            NameFull: Star‐Lack, Josh
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 05
              Text: May2018
              Type: published
              Y: 2018
          Identifiers:
            – Type: issn-print
              Value: 00942405
          Numbering:
            – Type: volume
              Value: 45
            – Type: issue
              Value: 5
          Titles:
            – TitleFull: Medical Physics
              Type: main
ResultId 1