The dependence of divertor power sharing on magnetic flux balance in near double-null configurations on Alcator C-Mod.
Saved in:
| Title: | The dependence of divertor power sharing on magnetic flux balance in near double-null configurations on Alcator C-Mod. |
|---|---|
| Authors: | D. Brunner1 brunner@mit.edu, A.Q. Kuang1, B. LaBombard1, J.L. Terry1 |
| Source: | Nuclear Fusion. Jul2018, Vol. 58 Issue 7, p1-1. 1p. |
| Subjects: | Magnetic flux, Fusion reactor divertors, Plasma gases, Diverters (Electronics), Stellarators |
| Abstract: | Management of power exhaust will be a crucial task for tokamak fusion reactors. Reactor concepts are often proposed with double-null divertors, i.e. having two magnetic separatrices in an up-down symmetric configuration. This arrangement is potentially advantageous since the majority of the tokamak exhaust power tends to flow to the outer pair of divertor legs at large major radius, where the geometry is favorable for spreading the heat over a large surface area and there is more room for advanced divertor configurations. Despite the importance, there have been relatively few studies of divertor power sharing in near double null configurations and no studies at the poloidal magnetic fields and scrape-off layer power widths anticipated for a reactor. Motivated by this need we have undertaken a systematic study on Alcator C-Mod, examining the effect of magnetic flux balance on the power sharing among the four divertor legs in near double-null plasmas. Ohmic L-modes at three values of plasma current and ICRF-heated enhanced D-alpha (EDA) H-modes and I-modes at a single value of plasma current are explored, producing poloidal magnetic fields of 0.42, 0.62 and 0.85 Tesla. For Ohmic L-modes and ICRF-heated EDA H-modes, we find that the point of equal power sharing between upper and lower divertors occurs remarkably close to a balanced double null. Power sharing amongst the outer (upper versus lower) and inner (upper versus lower) pairs of divertors can be described in terms of a logistic function of magnetic flux balance, consistent with heat flux mapping along magnetic field lines to the outer midplane. Power sharing between inner and outer legs is found to follow a Gaussian-like function of magnetic flux balance with non-zero power to the inner divertors at double null. The overall behavior of H-modes operated near double null and for I-modes operating to within one heat flux e-folding of double null are found similar to Ohmic L-modes, with a significant reduction of power on the inner divertor legs. The results are encapsulated in terms of empirically-informed analytic functions of magnetic flux balance. When combined with magnetic equilibrium control system specifications, these relationships can be used to specify the power flux handling requirements for each of the four divertor target plates. [ABSTRACT FROM AUTHOR] |
| Copyright of Nuclear Fusion is the property of IOP Publishing and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
| FullText | Text: Availability: 0 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 130506466 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: The dependence of divertor power sharing on magnetic flux balance in near double-null configurations on Alcator C-Mod. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22D%2E+Brunner%22">D. Brunner</searchLink><relatesTo>1</relatesTo><i> brunner@mit.edu</i><br /><searchLink fieldCode="AR" term="%22A%2EQ%2E+Kuang%22">A.Q. Kuang</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22B%2E+LaBombard%22">B. LaBombard</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22J%2EL%2E+Terry%22">J.L. Terry</searchLink><relatesTo>1</relatesTo> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Nuclear+Fusion%22">Nuclear Fusion</searchLink>. Jul2018, Vol. 58 Issue 7, p1-1. 1p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Magnetic+flux%22">Magnetic flux</searchLink><br /><searchLink fieldCode="DE" term="%22Fusion+reactor+divertors%22">Fusion reactor divertors</searchLink><br /><searchLink fieldCode="DE" term="%22Plasma+gases%22">Plasma gases</searchLink><br /><searchLink fieldCode="DE" term="%22Diverters+%28Electronics%29%22">Diverters (Electronics)</searchLink><br /><searchLink fieldCode="DE" term="%22Stellarators%22">Stellarators</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: Management of power exhaust will be a crucial task for tokamak fusion reactors. Reactor concepts are often proposed with double-null divertors, i.e. having two magnetic separatrices in an up-down symmetric configuration. This arrangement is potentially advantageous since the majority of the tokamak exhaust power tends to flow to the outer pair of divertor legs at large major radius, where the geometry is favorable for spreading the heat over a large surface area and there is more room for advanced divertor configurations. Despite the importance, there have been relatively few studies of divertor power sharing in near double null configurations and no studies at the poloidal magnetic fields and scrape-off layer power widths anticipated for a reactor. Motivated by this need we have undertaken a systematic study on Alcator C-Mod, examining the effect of magnetic flux balance on the power sharing among the four divertor legs in near double-null plasmas. Ohmic L-modes at three values of plasma current and ICRF-heated enhanced D-alpha (EDA) H-modes and I-modes at a single value of plasma current are explored, producing poloidal magnetic fields of 0.42, 0.62 and 0.85 Tesla. For Ohmic L-modes and ICRF-heated EDA H-modes, we find that the point of equal power sharing between upper and lower divertors occurs remarkably close to a balanced double null. Power sharing amongst the outer (upper versus lower) and inner (upper versus lower) pairs of divertors can be described in terms of a logistic function of magnetic flux balance, consistent with heat flux mapping along magnetic field lines to the outer midplane. Power sharing between inner and outer legs is found to follow a Gaussian-like function of magnetic flux balance with non-zero power to the inner divertors at double null. The overall behavior of H-modes operated near double null and for I-modes operating to within one heat flux e-folding of double null are found similar to Ohmic L-modes, with a significant reduction of power on the inner divertor legs. The results are encapsulated in terms of empirically-informed analytic functions of magnetic flux balance. When combined with magnetic equilibrium control system specifications, these relationships can be used to specify the power flux handling requirements for each of the four divertor target plates. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Nuclear Fusion is the property of IOP Publishing and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=130506466 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1088/1741-4326/aac006 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 1 StartPage: 1 Subjects: – SubjectFull: Magnetic flux Type: general – SubjectFull: Fusion reactor divertors Type: general – SubjectFull: Plasma gases Type: general – SubjectFull: Diverters (Electronics) Type: general – SubjectFull: Stellarators Type: general Titles: – TitleFull: The dependence of divertor power sharing on magnetic flux balance in near double-null configurations on Alcator C-Mod. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: D. Brunner – PersonEntity: Name: NameFull: A.Q. Kuang – PersonEntity: Name: NameFull: B. LaBombard – PersonEntity: Name: NameFull: J.L. Terry IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 07 Text: Jul2018 Type: published Y: 2018 Identifiers: – Type: issn-print Value: 00295515 Numbering: – Type: volume Value: 58 – Type: issue Value: 7 Titles: – TitleFull: Nuclear Fusion Type: main |
| ResultId | 1 |