Non-enhanced Pattern on Contrast-Enhanced Ultrasound in the Local Efficacy Assessment of Irreversible Electroporation Ablation of Pancreatic Adenocarcinoma.

Saved in:
Bibliographic Details
Title: Non-enhanced Pattern on Contrast-Enhanced Ultrasound in the Local Efficacy Assessment of Irreversible Electroporation Ablation of Pancreatic Adenocarcinoma.
Authors: Lin, Manxia1, Xie, Xiaoyan1, Xu, Ming1, Feng, Shiting2, Tian, Wenshuo1, Zhuang, Bowen1, Su, Liya1, Ye, Jieyi1, Lin, Jinhua1, Liang, Ping3, Yu, Jie3, Kuang, Ming1,4 kuangm@mail.sysu.edu.cn
Source: Ultrasound in Medicine & Biology. Sep2018, Vol. 44 Issue 9, p1986-1995. 10p.
Subjects: Ultrasonic imaging, Electroporation, Adenocarcinoma, Pancreatic cancer diagnosis, Diagnosis, Patients
Abstract: The objective was to evaluate the diagnostic value of contrast-enhanced ultrasound in the assessment of the local efficacy after irreversible electroporation (IRE) ablation of pancreatic adenocarcinoma 1 mo after ablation. Fifteen patients with pancreatic adenocarcinoma were treated with IRE and then examined by contrast-enhanced ultrasound 1 mo after ablation. The contrast agent was SonoVue. Technical efficacy was assessed at 3 mo after IRE and classified as technical efficiency (TE) and technical inefficiency (TIE). Diagnostic performance was analyzed using a receiver operating characteristic curve. Ten patients were considered as having TE, and five, TIE. Complete non-enhancement was observed in seven ablation zones (70.0%) in the TE group, and peripheral heterogeneous enhancement, in all five ablation zones (100.0%) in the TIE group. The non-enhancement pattern differed significantly between the TE and TIE groups (p = 0.026), with significant correlation with technical efficacy (p = 0.007). The area under the receiver operating characteristic curve was 0.85 (p = 0.008, 95% confidence interval: 0.65-1.05). A non-enhancement pattern using contrast-enhanced ultrasound was useful in the assessment of local efficacy after IRE ablation of pancreatic adenocarcinoma. [ABSTRACT FROM AUTHOR]
Copyright of Ultrasound in Medicine & Biology is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 131317406
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Non-enhanced Pattern on Contrast-Enhanced Ultrasound in the Local Efficacy Assessment of Irreversible Electroporation Ablation of Pancreatic Adenocarcinoma.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Lin%2C+Manxia%22">Lin, Manxia</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Xie%2C+Xiaoyan%22">Xie, Xiaoyan</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Xu%2C+Ming%22">Xu, Ming</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Feng%2C+Shiting%22">Feng, Shiting</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Tian%2C+Wenshuo%22">Tian, Wenshuo</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Zhuang%2C+Bowen%22">Zhuang, Bowen</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Su%2C+Liya%22">Su, Liya</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Ye%2C+Jieyi%22">Ye, Jieyi</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Lin%2C+Jinhua%22">Lin, Jinhua</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Liang%2C+Ping%22">Liang, Ping</searchLink><relatesTo>3</relatesTo><br /><searchLink fieldCode="AR" term="%22Yu%2C+Jie%22">Yu, Jie</searchLink><relatesTo>3</relatesTo><br /><searchLink fieldCode="AR" term="%22Kuang%2C+Ming%22">Kuang, Ming</searchLink><relatesTo>1,4</relatesTo><i> kuangm@mail.sysu.edu.cn</i>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Ultrasound+in+Medicine+%26+Biology%22">Ultrasound in Medicine & Biology</searchLink>. Sep2018, Vol. 44 Issue 9, p1986-1995. 10p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Ultrasonic+imaging%22">Ultrasonic imaging</searchLink><br /><searchLink fieldCode="DE" term="%22Electroporation%22">Electroporation</searchLink><br /><searchLink fieldCode="DE" term="%22Adenocarcinoma%22">Adenocarcinoma</searchLink><br /><searchLink fieldCode="DE" term="%22Pancreatic+cancer+diagnosis%22">Pancreatic cancer diagnosis</searchLink><br /><searchLink fieldCode="DE" term="%22Diagnosis%22">Diagnosis</searchLink><br /><searchLink fieldCode="DE" term="%22Patients%22">Patients</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: The objective was to evaluate the diagnostic value of contrast-enhanced ultrasound in the assessment of the local efficacy after irreversible electroporation (IRE) ablation of pancreatic adenocarcinoma 1 mo after ablation. Fifteen patients with pancreatic adenocarcinoma were treated with IRE and then examined by contrast-enhanced ultrasound 1 mo after ablation. The contrast agent was SonoVue. Technical efficacy was assessed at 3 mo after IRE and classified as technical efficiency (TE) and technical inefficiency (TIE). Diagnostic performance was analyzed using a receiver operating characteristic curve. Ten patients were considered as having TE, and five, TIE. Complete non-enhancement was observed in seven ablation zones (70.0%) in the TE group, and peripheral heterogeneous enhancement, in all five ablation zones (100.0%) in the TIE group. The non-enhancement pattern differed significantly between the TE and TIE groups (p = 0.026), with significant correlation with technical efficacy (p = 0.007). The area under the receiver operating characteristic curve was 0.85 (p = 0.008, 95% confidence interval: 0.65-1.05). A non-enhancement pattern using contrast-enhanced ultrasound was useful in the assessment of local efficacy after IRE ablation of pancreatic adenocarcinoma. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Ultrasound in Medicine & Biology is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=131317406
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1016/j.ultrasmedbio.2018.05.018
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 10
        StartPage: 1986
    Subjects:
      – SubjectFull: Ultrasonic imaging
        Type: general
      – SubjectFull: Electroporation
        Type: general
      – SubjectFull: Adenocarcinoma
        Type: general
      – SubjectFull: Pancreatic cancer diagnosis
        Type: general
      – SubjectFull: Diagnosis
        Type: general
      – SubjectFull: Patients
        Type: general
    Titles:
      – TitleFull: Non-enhanced Pattern on Contrast-Enhanced Ultrasound in the Local Efficacy Assessment of Irreversible Electroporation Ablation of Pancreatic Adenocarcinoma.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Lin, Manxia
      – PersonEntity:
          Name:
            NameFull: Xie, Xiaoyan
      – PersonEntity:
          Name:
            NameFull: Xu, Ming
      – PersonEntity:
          Name:
            NameFull: Feng, Shiting
      – PersonEntity:
          Name:
            NameFull: Tian, Wenshuo
      – PersonEntity:
          Name:
            NameFull: Zhuang, Bowen
      – PersonEntity:
          Name:
            NameFull: Su, Liya
      – PersonEntity:
          Name:
            NameFull: Ye, Jieyi
      – PersonEntity:
          Name:
            NameFull: Lin, Jinhua
      – PersonEntity:
          Name:
            NameFull: Liang, Ping
      – PersonEntity:
          Name:
            NameFull: Yu, Jie
      – PersonEntity:
          Name:
            NameFull: Kuang, Ming
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 09
              Text: Sep2018
              Type: published
              Y: 2018
          Identifiers:
            – Type: issn-print
              Value: 03015629
          Numbering:
            – Type: volume
              Value: 44
            – Type: issue
              Value: 9
          Titles:
            – TitleFull: Ultrasound in Medicine & Biology
              Type: main
ResultId 1