Non-enhanced Pattern on Contrast-Enhanced Ultrasound in the Local Efficacy Assessment of Irreversible Electroporation Ablation of Pancreatic Adenocarcinoma.
Saved in:
| Title: | Non-enhanced Pattern on Contrast-Enhanced Ultrasound in the Local Efficacy Assessment of Irreversible Electroporation Ablation of Pancreatic Adenocarcinoma. |
|---|---|
| Authors: | Lin, Manxia1, Xie, Xiaoyan1, Xu, Ming1, Feng, Shiting2, Tian, Wenshuo1, Zhuang, Bowen1, Su, Liya1, Ye, Jieyi1, Lin, Jinhua1, Liang, Ping3, Yu, Jie3, Kuang, Ming1,4 kuangm@mail.sysu.edu.cn |
| Source: | Ultrasound in Medicine & Biology. Sep2018, Vol. 44 Issue 9, p1986-1995. 10p. |
| Subjects: | Ultrasonic imaging, Electroporation, Adenocarcinoma, Pancreatic cancer diagnosis, Diagnosis, Patients |
| Abstract: | The objective was to evaluate the diagnostic value of contrast-enhanced ultrasound in the assessment of the local efficacy after irreversible electroporation (IRE) ablation of pancreatic adenocarcinoma 1 mo after ablation. Fifteen patients with pancreatic adenocarcinoma were treated with IRE and then examined by contrast-enhanced ultrasound 1 mo after ablation. The contrast agent was SonoVue. Technical efficacy was assessed at 3 mo after IRE and classified as technical efficiency (TE) and technical inefficiency (TIE). Diagnostic performance was analyzed using a receiver operating characteristic curve. Ten patients were considered as having TE, and five, TIE. Complete non-enhancement was observed in seven ablation zones (70.0%) in the TE group, and peripheral heterogeneous enhancement, in all five ablation zones (100.0%) in the TIE group. The non-enhancement pattern differed significantly between the TE and TIE groups (p = 0.026), with significant correlation with technical efficacy (p = 0.007). The area under the receiver operating characteristic curve was 0.85 (p = 0.008, 95% confidence interval: 0.65-1.05). A non-enhancement pattern using contrast-enhanced ultrasound was useful in the assessment of local efficacy after IRE ablation of pancreatic adenocarcinoma. [ABSTRACT FROM AUTHOR] |
| Copyright of Ultrasound in Medicine & Biology is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
| FullText | Text: Availability: 0 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 131317406 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Non-enhanced Pattern on Contrast-Enhanced Ultrasound in the Local Efficacy Assessment of Irreversible Electroporation Ablation of Pancreatic Adenocarcinoma. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Lin%2C+Manxia%22">Lin, Manxia</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Xie%2C+Xiaoyan%22">Xie, Xiaoyan</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Xu%2C+Ming%22">Xu, Ming</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Feng%2C+Shiting%22">Feng, Shiting</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Tian%2C+Wenshuo%22">Tian, Wenshuo</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Zhuang%2C+Bowen%22">Zhuang, Bowen</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Su%2C+Liya%22">Su, Liya</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Ye%2C+Jieyi%22">Ye, Jieyi</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Lin%2C+Jinhua%22">Lin, Jinhua</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Liang%2C+Ping%22">Liang, Ping</searchLink><relatesTo>3</relatesTo><br /><searchLink fieldCode="AR" term="%22Yu%2C+Jie%22">Yu, Jie</searchLink><relatesTo>3</relatesTo><br /><searchLink fieldCode="AR" term="%22Kuang%2C+Ming%22">Kuang, Ming</searchLink><relatesTo>1,4</relatesTo><i> kuangm@mail.sysu.edu.cn</i> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Ultrasound+in+Medicine+%26+Biology%22">Ultrasound in Medicine & Biology</searchLink>. Sep2018, Vol. 44 Issue 9, p1986-1995. 10p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Ultrasonic+imaging%22">Ultrasonic imaging</searchLink><br /><searchLink fieldCode="DE" term="%22Electroporation%22">Electroporation</searchLink><br /><searchLink fieldCode="DE" term="%22Adenocarcinoma%22">Adenocarcinoma</searchLink><br /><searchLink fieldCode="DE" term="%22Pancreatic+cancer+diagnosis%22">Pancreatic cancer diagnosis</searchLink><br /><searchLink fieldCode="DE" term="%22Diagnosis%22">Diagnosis</searchLink><br /><searchLink fieldCode="DE" term="%22Patients%22">Patients</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: The objective was to evaluate the diagnostic value of contrast-enhanced ultrasound in the assessment of the local efficacy after irreversible electroporation (IRE) ablation of pancreatic adenocarcinoma 1 mo after ablation. Fifteen patients with pancreatic adenocarcinoma were treated with IRE and then examined by contrast-enhanced ultrasound 1 mo after ablation. The contrast agent was SonoVue. Technical efficacy was assessed at 3 mo after IRE and classified as technical efficiency (TE) and technical inefficiency (TIE). Diagnostic performance was analyzed using a receiver operating characteristic curve. Ten patients were considered as having TE, and five, TIE. Complete non-enhancement was observed in seven ablation zones (70.0%) in the TE group, and peripheral heterogeneous enhancement, in all five ablation zones (100.0%) in the TIE group. The non-enhancement pattern differed significantly between the TE and TIE groups (p = 0.026), with significant correlation with technical efficacy (p = 0.007). The area under the receiver operating characteristic curve was 0.85 (p = 0.008, 95% confidence interval: 0.65-1.05). A non-enhancement pattern using contrast-enhanced ultrasound was useful in the assessment of local efficacy after IRE ablation of pancreatic adenocarcinoma. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Ultrasound in Medicine & Biology is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=131317406 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1016/j.ultrasmedbio.2018.05.018 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 10 StartPage: 1986 Subjects: – SubjectFull: Ultrasonic imaging Type: general – SubjectFull: Electroporation Type: general – SubjectFull: Adenocarcinoma Type: general – SubjectFull: Pancreatic cancer diagnosis Type: general – SubjectFull: Diagnosis Type: general – SubjectFull: Patients Type: general Titles: – TitleFull: Non-enhanced Pattern on Contrast-Enhanced Ultrasound in the Local Efficacy Assessment of Irreversible Electroporation Ablation of Pancreatic Adenocarcinoma. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Lin, Manxia – PersonEntity: Name: NameFull: Xie, Xiaoyan – PersonEntity: Name: NameFull: Xu, Ming – PersonEntity: Name: NameFull: Feng, Shiting – PersonEntity: Name: NameFull: Tian, Wenshuo – PersonEntity: Name: NameFull: Zhuang, Bowen – PersonEntity: Name: NameFull: Su, Liya – PersonEntity: Name: NameFull: Ye, Jieyi – PersonEntity: Name: NameFull: Lin, Jinhua – PersonEntity: Name: NameFull: Liang, Ping – PersonEntity: Name: NameFull: Yu, Jie – PersonEntity: Name: NameFull: Kuang, Ming IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 09 Text: Sep2018 Type: published Y: 2018 Identifiers: – Type: issn-print Value: 03015629 Numbering: – Type: volume Value: 44 – Type: issue Value: 9 Titles: – TitleFull: Ultrasound in Medicine & Biology Type: main |
| ResultId | 1 |