Effects of different treatments on chemical and morphological features of eroded dentin.

Saved in:
Bibliographic Details
Title: Effects of different treatments on chemical and morphological features of eroded dentin.
Authors: Moura, Sandra Kiss1,2 kissmoura@gmail.com, Lopes, Carolina Cury1, Trevelin, Livia Tosi3, Matos, Adriana Bona3, Martinez, Íssis Virgínia Luque4, Estevam, Marcelo5, Bussadori, Sandra Kalil2
Source: Lasers in Medical Science. Sep2018, Vol. 33 Issue 7, p1441-1446. 6p.
Subjects: Dentin, Tooth erosion, Eating disorders, Gastroesophageal reflux, Laser ablation, Laser therapy, Phosphorus analysis, Calcium, Combination drug therapy, Fluorides, Nitrates, Phosphates, X-ray spectroscopy
Abstract: To evaluate the treatment of eroded dentin (Sensodyne Repair & Protect™, Er:YAG laser and combinations). The occlusal surfaces of 25 third molars were sectioned 1.5 mm in thickness. After an erosion cycle (5 min in demineralizing solution + 3 h in remineralizing solution; six cycles a day for 8 days), the samples were divided into five groups (n = 5): (E) erosion - control; (ES) erosion + Sensodyne Repair & Protect (NovaMin); (EL) erosion + Er:YAG laser (40 mJ, 10 Hz, 0.4 W, 50 μs, 3.1 J/cm2, 63 W/cm2); (ELS) erosion + Er:YAG laser + Sensodyne; and (ESL) erosion + Sensodyne + Er:YAG laser. Following storage in ultrapure water (37 °C/14 days), the Ca/P ratio was evaluated by EDXRF and the morphology surfaces examined in SEM. The percentage of exposed dentin tubules was calculated. One-way analysis of variance and Tukey's test at 5% were used to treat the data. The Ca/P ratio was higher in E and ES groups. More exposed dentin tubules were found in E group and less exposed tubules were found in the ES group (p < 0.0001). When the toothpaste and laser were combined, the number of occluded dentin tubules was higher when laser was performed first (ELS). A positive effect was found when the laser and toothpaste were combined. [ABSTRACT FROM AUTHOR]
Copyright of Lasers in Medical Science is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
Be the first to leave a comment!
You must be logged in first