Sub‐microsecond‐resolved multi‐speckle X‐ray photon correlation spectroscopy with a pixel array detector.

Saved in:
Bibliographic Details
Title: Sub‐microsecond‐resolved multi‐speckle X‐ray photon correlation spectroscopy with a pixel array detector.
Authors: Zhang, Qingteng1, Dufresne, Eric M.1, Narayanan, Suresh1, Maj, Piotr2, Koziol, Anna2, Szczygiel, Robert2, Grybos, Pawel2, Sutton, Mark3, Sandy, Alec R.1 asandy@anl.gov
Source: Journal of Synchrotron Radiation. Sep2018, Vol. 25 Issue 5, p1408-1416. 8p.
Subjects: Light beating spectroscopy, Infrared array detectors, Silica gel, Temperature effect, Photon counting
Abstract: Small‐angle X‐ray photon correlation spectroscopy (XPCS) measurements spanning delay times from 826 ns to 52.8 s were performed using a photon‐counting pixel array detector with a dynamic range of 0–3 (2 bits). Fine resolution and a wide dynamic range of time scales was achieved by combining two modes of operation of the detector: (i) continuous mode, where data acquisition and data readout are performed in parallel with a frame acquisition time of 19.36 µs, and (ii) burst mode, where 12 frames are acquired with frame integration times of either 2.56 µs frame−1 or 826 ns frame−1 followed by 3.49 ms or 1.16 ms, respectively, for readout. The applicability of the detector for performing multi‐speckle XPCS was demonstrated by measuring the Brownian dynamics of 10 nm‐radius gold and 57 nm‐radius silica colloids in water at room temperature. In addition, the capability of the detector to faithfully record one‐ and two‐photon counts was examined by comparing the statistical distribution of photon counts with expected probabilities from the negative binomial distribution. It was found that in burst mode the ratio of 2 s to 1 s is markedly smaller than predicted and that this is attributable to pixel‐response dead‐time. [ABSTRACT FROM AUTHOR]
Copyright of Journal of Synchrotron Radiation is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: egs
DbLabel: Engineering Source
An: 132088716
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Sub‐microsecond‐resolved multi‐speckle X‐ray photon correlation spectroscopy with a pixel array detector.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Zhang%2C+Qingteng%22">Zhang, Qingteng</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Dufresne%2C+Eric+M%2E%22">Dufresne, Eric M.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Narayanan%2C+Suresh%22">Narayanan, Suresh</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Maj%2C+Piotr%22">Maj, Piotr</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Koziol%2C+Anna%22">Koziol, Anna</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Szczygiel%2C+Robert%22">Szczygiel, Robert</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Grybos%2C+Pawel%22">Grybos, Pawel</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Sutton%2C+Mark%22">Sutton, Mark</searchLink><relatesTo>3</relatesTo><br /><searchLink fieldCode="AR" term="%22Sandy%2C+Alec+R%2E%22">Sandy, Alec R.</searchLink><relatesTo>1</relatesTo><i> asandy@anl.gov</i>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Journal+of+Synchrotron+Radiation%22">Journal of Synchrotron Radiation</searchLink>. Sep2018, Vol. 25 Issue 5, p1408-1416. 8p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Light+beating+spectroscopy%22">Light beating spectroscopy</searchLink><br /><searchLink fieldCode="DE" term="%22Infrared+array+detectors%22">Infrared array detectors</searchLink><br /><searchLink fieldCode="DE" term="%22Silica+gel%22">Silica gel</searchLink><br /><searchLink fieldCode="DE" term="%22Temperature+effect%22">Temperature effect</searchLink><br /><searchLink fieldCode="DE" term="%22Photon+counting%22">Photon counting</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Small‐angle X‐ray photon correlation spectroscopy (XPCS) measurements spanning delay times from 826 ns to 52.8 s were performed using a photon‐counting pixel array detector with a dynamic range of 0–3 (2 bits). Fine resolution and a wide dynamic range of time scales was achieved by combining two modes of operation of the detector: (i) continuous mode, where data acquisition and data readout are performed in parallel with a frame acquisition time of 19.36 µs, and (ii) burst mode, where 12 frames are acquired with frame integration times of either 2.56 µs frame−1 or 826 ns frame−1 followed by 3.49 ms or 1.16 ms, respectively, for readout. The applicability of the detector for performing multi‐speckle XPCS was demonstrated by measuring the Brownian dynamics of 10 nm‐radius gold and 57 nm‐radius silica colloids in water at room temperature. In addition, the capability of the detector to faithfully record one‐ and two‐photon counts was examined by comparing the statistical distribution of photon counts with expected probabilities from the negative binomial distribution. It was found that in burst mode the ratio of 2 s to 1 s is markedly smaller than predicted and that this is attributable to pixel‐response dead‐time. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Journal of Synchrotron Radiation is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=132088716
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1107/S1600577518009074
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 8
        StartPage: 1408
    Subjects:
      – SubjectFull: Light beating spectroscopy
        Type: general
      – SubjectFull: Infrared array detectors
        Type: general
      – SubjectFull: Silica gel
        Type: general
      – SubjectFull: Temperature effect
        Type: general
      – SubjectFull: Photon counting
        Type: general
    Titles:
      – TitleFull: Sub‐microsecond‐resolved multi‐speckle X‐ray photon correlation spectroscopy with a pixel array detector.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Zhang, Qingteng
      – PersonEntity:
          Name:
            NameFull: Dufresne, Eric M.
      – PersonEntity:
          Name:
            NameFull: Narayanan, Suresh
      – PersonEntity:
          Name:
            NameFull: Maj, Piotr
      – PersonEntity:
          Name:
            NameFull: Koziol, Anna
      – PersonEntity:
          Name:
            NameFull: Szczygiel, Robert
      – PersonEntity:
          Name:
            NameFull: Grybos, Pawel
      – PersonEntity:
          Name:
            NameFull: Sutton, Mark
      – PersonEntity:
          Name:
            NameFull: Sandy, Alec R.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 09
              Text: Sep2018
              Type: published
              Y: 2018
          Identifiers:
            – Type: issn-print
              Value: 09090495
          Numbering:
            – Type: volume
              Value: 25
            – Type: issue
              Value: 5
          Titles:
            – TitleFull: Journal of Synchrotron Radiation
              Type: main
ResultId 1