High-throughput sample preparation procedures for the quantitation of a new bone integrin ανβ3 antagonist in human plasma and urine using liquid chromatography–tandem mass spectrometry

Saved in:
Bibliographic Details
Title: High-throughput sample preparation procedures for the quantitation of a new bone integrin ανβ3 antagonist in human plasma and urine using liquid chromatography–tandem mass spectrometry
Authors: Zhang, Jin jin_zhang@merck.com, Zeng, W.1, Kitchen, C.1, Wang, A.Q.1, Musson, D.G.1
Source: Journal of Chromatography B: Analytical Technologies in the Biomedical & Life Sciences. Jul2004, Vol. 806 Issue 2, p167-175. 9p.
Subjects: Bones, Integrins, Blood plasma, Urine, Calibration
Abstract: High throughput LC–MS/MS assays to quantitate a new ανβ3 bone integrin antagonist (I) in human plasma and urine have been developed using instruments programmed to automate sample preparation procedures. Packard liquid handling system-MultiPROBE® II EX was programmed for preparing calibration standards in control plasma and urine, acidifying all standards, quality control (QC), and clinical samples with necessary dilutions, and adding the internal standard to the acidified samples. TOMTEC Quadra 96™ was programmed to perform the solid phase extraction (SPE) process on a 3 M 96-well mixed phase cation standard density (MPC-SD) plate to isolate the analytes from the sample matrix. The extract collected from both types of matrices was directly injected into reversed-phase LC–MS/MS system with a Turbo Ion Spray (TIS) interface in the positive ionization mode. The plasma and urine assays have the calibration range of 0.5–1500 and 2–6000 ng/mL, respectively. Validation of the automated and the manual plasma assays showed that application of MultiPROBE II to sample preparation gave comparable accuracy and precision. Overall, the automated approaches with minimum manual intervention enhanced the throughput of sample preparation. [Copyright &y& Elsevier]
Copyright of Journal of Chromatography B: Analytical Technologies in the Biomedical & Life Sciences is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 13236221
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: High-throughput sample preparation procedures for the quantitation of a new bone integrin α<subscript>ν</subscript>β<subscript>3</subscript> antagonist in human plasma and urine using liquid chromatography–tandem mass spectrometry
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Zhang%2C+Jin%22">Zhang, Jin</searchLink><i> jin_zhang@merck.com</i><br /><searchLink fieldCode="AR" term="%22Zeng%2C+W%2E%22">Zeng, W.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Kitchen%2C+C%2E%22">Kitchen, C.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Wang%2C+A%2EQ%2E%22">Wang, A.Q.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Musson%2C+D%2EG%2E%22">Musson, D.G.</searchLink><relatesTo>1</relatesTo>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Journal+of+Chromatography+B%3A+Analytical+Technologies+in+the+Biomedical+%26+Life+Sciences%22">Journal of Chromatography B: Analytical Technologies in the Biomedical & Life Sciences</searchLink>. Jul2004, Vol. 806 Issue 2, p167-175. 9p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Bones%22">Bones</searchLink><br /><searchLink fieldCode="DE" term="%22Integrins%22">Integrins</searchLink><br /><searchLink fieldCode="DE" term="%22Blood+plasma%22">Blood plasma</searchLink><br /><searchLink fieldCode="DE" term="%22Urine%22">Urine</searchLink><br /><searchLink fieldCode="DE" term="%22Calibration%22">Calibration</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: High throughput LC–MS/MS assays to quantitate a new ανβ3 bone integrin antagonist (I) in human plasma and urine have been developed using instruments programmed to automate sample preparation procedures. Packard liquid handling system-MultiPROBE® II EX was programmed for preparing calibration standards in control plasma and urine, acidifying all standards, quality control (QC), and clinical samples with necessary dilutions, and adding the internal standard to the acidified samples. TOMTEC Quadra 96™ was programmed to perform the solid phase extraction (SPE) process on a 3 M 96-well mixed phase cation standard density (MPC-SD) plate to isolate the analytes from the sample matrix. The extract collected from both types of matrices was directly injected into reversed-phase LC–MS/MS system with a Turbo Ion Spray (TIS) interface in the positive ionization mode. The plasma and urine assays have the calibration range of 0.5–1500 and 2–6000 ng/mL, respectively. Validation of the automated and the manual plasma assays showed that application of MultiPROBE II to sample preparation gave comparable accuracy and precision. Overall, the automated approaches with minimum manual intervention enhanced the throughput of sample preparation. [Copyright &y& Elsevier]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Journal of Chromatography B: Analytical Technologies in the Biomedical & Life Sciences is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=13236221
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1016/j.jchromb.2004.03.056
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 9
        StartPage: 167
    Subjects:
      – SubjectFull: Bones
        Type: general
      – SubjectFull: Integrins
        Type: general
      – SubjectFull: Blood plasma
        Type: general
      – SubjectFull: Urine
        Type: general
      – SubjectFull: Calibration
        Type: general
    Titles:
      – TitleFull: High-throughput sample preparation procedures for the quantitation of a new bone integrin ανβ3 antagonist in human plasma and urine using liquid chromatography–tandem mass spectrometry
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Zhang, Jin
      – PersonEntity:
          Name:
            NameFull: Zeng, W.
      – PersonEntity:
          Name:
            NameFull: Kitchen, C.
      – PersonEntity:
          Name:
            NameFull: Wang, A.Q.
      – PersonEntity:
          Name:
            NameFull: Musson, D.G.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 05
              M: 07
              Text: Jul2004
              Type: published
              Y: 2004
          Identifiers:
            – Type: issn-print
              Value: 15700232
          Numbering:
            – Type: volume
              Value: 806
            – Type: issue
              Value: 2
          Titles:
            – TitleFull: Journal of Chromatography B: Analytical Technologies in the Biomedical & Life Sciences
              Type: main
ResultId 1