Numerical studies of the influence of various geometrical features of a multispiked connecting scaffold prototype on mechanical stresses in peri-implant bone.

Saved in:
Bibliographic Details
Title: Numerical studies of the influence of various geometrical features of a multispiked connecting scaffold prototype on mechanical stresses in peri-implant bone.
Authors: Uklejewski, Ryszard1,2, Winiecki, Mariusz1,2, Patalas, Adam2, Rogala, Piotr3
Source: Computer Methods in Biomechanics & Biomedical Engineering. Jul2018, Vol. 21 Issue 9, p541-547. 7p.
Subjects: Mechanical stress analysis, Arthroplasty, Total hip replacement, Artificial joints, Biomechanics, Bioengineering
Abstract: The multispiked connecting scaffold (MSC-scaffold) prototype is an essential innovation in the fixation of components of resurfacing arthroplasty (RA) endoprostheses, providing their entirely non-cemented and bone-tissue-preserving fixation in peri-articular bone. An FE study is proposed to evaluate the influence of geometrical features of the MSC-scaffold on the transfer of mechanical load in peri-implant bone. For this study, an FE model of Ti-Alloy MSC-scaffold prototype embedded in a bilinear elastic, transversely isotropic bone material was built. For the compressive load on the MSC-scaffold, maps of Huber-Mises-Hencky (HMH) stress in peri-implant bone were determined. The influence of the distance between the bases of neighbouring spikes, the apex angle of spikes, and the height of the spherical cup of spikes of the MSC-scaffold were analysed. It was found that the changes in the distance between the bases of neighbouring spikes from 0.2 to 0.5 mm cause the HMH stress to increase in bone material by 32%. The changes of the apex angle of spikes from 2° to 4° decrease the HMH stress in bone material by 39%. The changes of height of the spherical cup of spikes from 0 to 0.12 mm increase the HMH stress in bone material by 24%. In conclusion, the spikes' apex angle and the distance between the bases of spikes of the MSC-scaffold are the key geometrical features determining the appropriate MSC-scaffold prototype design. The built FE model was found to be useful in bioengineering design of the novel fixation system for RA endoprostheses by means of the MSC-scaffold. [ABSTRACT FROM AUTHOR]
Copyright of Computer Methods in Biomechanics & Biomedical Engineering is the property of Taylor & Francis Ltd and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 134057193
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Numerical studies of the influence of various geometrical features of a multispiked connecting scaffold prototype on mechanical stresses in peri-implant bone.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Uklejewski%2C+Ryszard%22">Uklejewski, Ryszard</searchLink><relatesTo>1,2</relatesTo><br /><searchLink fieldCode="AR" term="%22Winiecki%2C+Mariusz%22">Winiecki, Mariusz</searchLink><relatesTo>1,2</relatesTo><br /><searchLink fieldCode="AR" term="%22Patalas%2C+Adam%22">Patalas, Adam</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Rogala%2C+Piotr%22">Rogala, Piotr</searchLink><relatesTo>3</relatesTo>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Computer+Methods+in+Biomechanics+%26+Biomedical+Engineering%22">Computer Methods in Biomechanics & Biomedical Engineering</searchLink>. Jul2018, Vol. 21 Issue 9, p541-547. 7p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Mechanical+stress+analysis%22">Mechanical stress analysis</searchLink><br /><searchLink fieldCode="DE" term="%22Arthroplasty%22">Arthroplasty</searchLink><br /><searchLink fieldCode="DE" term="%22Total+hip+replacement%22">Total hip replacement</searchLink><br /><searchLink fieldCode="DE" term="%22Artificial+joints%22">Artificial joints</searchLink><br /><searchLink fieldCode="DE" term="%22Biomechanics%22">Biomechanics</searchLink><br /><searchLink fieldCode="DE" term="%22Bioengineering%22">Bioengineering</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: The multispiked connecting scaffold (MSC-scaffold) prototype is an essential innovation in the fixation of components of resurfacing arthroplasty (RA) endoprostheses, providing their entirely non-cemented and bone-tissue-preserving fixation in peri-articular bone. An FE study is proposed to evaluate the influence of geometrical features of the MSC-scaffold on the transfer of mechanical load in peri-implant bone. For this study, an FE model of Ti-Alloy MSC-scaffold prototype embedded in a bilinear elastic, transversely isotropic bone material was built. For the compressive load on the MSC-scaffold, maps of Huber-Mises-Hencky (HMH) stress in peri-implant bone were determined. The influence of the distance between the bases of neighbouring spikes, the apex angle of spikes, and the height of the spherical cup of spikes of the MSC-scaffold were analysed. It was found that the changes in the distance between the bases of neighbouring spikes from 0.2 to 0.5 mm cause the HMH stress to increase in bone material by 32%. The changes of the apex angle of spikes from 2° to 4° decrease the HMH stress in bone material by 39%. The changes of height of the spherical cup of spikes from 0 to 0.12 mm increase the HMH stress in bone material by 24%. In conclusion, the spikes' apex angle and the distance between the bases of spikes of the MSC-scaffold are the key geometrical features determining the appropriate MSC-scaffold prototype design. The built FE model was found to be useful in bioengineering design of the novel fixation system for RA endoprostheses by means of the MSC-scaffold. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Computer Methods in Biomechanics & Biomedical Engineering is the property of Taylor & Francis Ltd and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=134057193
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1080/10255842.2018.1480759
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 7
        StartPage: 541
    Subjects:
      – SubjectFull: Mechanical stress analysis
        Type: general
      – SubjectFull: Arthroplasty
        Type: general
      – SubjectFull: Total hip replacement
        Type: general
      – SubjectFull: Artificial joints
        Type: general
      – SubjectFull: Biomechanics
        Type: general
      – SubjectFull: Bioengineering
        Type: general
    Titles:
      – TitleFull: Numerical studies of the influence of various geometrical features of a multispiked connecting scaffold prototype on mechanical stresses in peri-implant bone.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Uklejewski, Ryszard
      – PersonEntity:
          Name:
            NameFull: Winiecki, Mariusz
      – PersonEntity:
          Name:
            NameFull: Patalas, Adam
      – PersonEntity:
          Name:
            NameFull: Rogala, Piotr
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 07
              Text: Jul2018
              Type: published
              Y: 2018
          Identifiers:
            – Type: issn-print
              Value: 10255842
          Numbering:
            – Type: volume
              Value: 21
            – Type: issue
              Value: 9
          Titles:
            – TitleFull: Computer Methods in Biomechanics & Biomedical Engineering
              Type: main
ResultId 1