Stability testing blister packs inspected with Sepha's VisionScan test method.

Saved in:
Bibliographic Details
Title: Stability testing blister packs inspected with Sepha's VisionScan test method.
Authors: Dixon, D.1 author.ppp@gmail.com
Source: Popular Plastics & Packaging. Jan2020, Vol. 65 Issue 1, p32-42. 6p.
Subjects: Leak detection, Methods engineering, Test systems, Imaging systems
Abstract: The Sepha VisionScan leak detection system tests the integrity of blister packs using vacuum and vision technologic The method works by creating a vacuum around a blister pack while a high-resolution imaging system monitors changes in the individual blister pockets. Any difference in pocket shape which deviates from the expected behaviour when establishing the vacuum, or during the dwell time of the vacuum, indicates leakage of air from the blister pocket. This is based on the principle in the ASTM standard F3169. A stability study was set up to investigate if the Sepha VisionScan test method impacts the integrity of blister pockets. The study reports on the tablet moisture determination (which will be an indicator of changes in the integrity of the blister) by stability testing blister packs which have been leak tested in the Sepha VisionScan system versus blister packs which have not been leak tested in the VisionScan. The stability study testing is conducted on blisters which are constructed from the following materials PVC/PVdC, PVC/PE/PCTFE (ACLAR), ALU/ALU The study shows there is no significant difference in the integrity of blisters when inspected with the Sepha VisionScan leak detection system compared to blisters not inspected by the system and proves the VisionScan technique is a non-destructive solution to assure package integrity. [ABSTRACT FROM AUTHOR]
Copyright of Popular Plastics & Packaging is the property of Colour Publications Pvt, Ltd. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Links:
  – Type: pdflink
Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 141535478
AccessLevel: 6
PubType: Periodical
PubTypeId: serialPeriodical
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Stability testing blister packs inspected with Sepha's VisionScan test method.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Dixon%2C+D%2E%22">Dixon, D.</searchLink><relatesTo>1</relatesTo><i> author.ppp@gmail.com</i>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Popular+Plastics+%26+Packaging%22">Popular Plastics & Packaging</searchLink>. Jan2020, Vol. 65 Issue 1, p32-42. 6p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Leak+detection%22">Leak detection</searchLink><br /><searchLink fieldCode="DE" term="%22Methods+engineering%22">Methods engineering</searchLink><br /><searchLink fieldCode="DE" term="%22Test+systems%22">Test systems</searchLink><br /><searchLink fieldCode="DE" term="%22Imaging+systems%22">Imaging systems</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: The Sepha VisionScan leak detection system tests the integrity of blister packs using vacuum and vision technologic The method works by creating a vacuum around a blister pack while a high-resolution imaging system monitors changes in the individual blister pockets. Any difference in pocket shape which deviates from the expected behaviour when establishing the vacuum, or during the dwell time of the vacuum, indicates leakage of air from the blister pocket. This is based on the principle in the ASTM standard F3169. A stability study was set up to investigate if the Sepha VisionScan test method impacts the integrity of blister pockets. The study reports on the tablet moisture determination (which will be an indicator of changes in the integrity of the blister) by stability testing blister packs which have been leak tested in the Sepha VisionScan system versus blister packs which have not been leak tested in the VisionScan. The stability study testing is conducted on blisters which are constructed from the following materials PVC/PVdC, PVC/PE/PCTFE (ACLAR), ALU/ALU The study shows there is no significant difference in the integrity of blisters when inspected with the Sepha VisionScan leak detection system compared to blisters not inspected by the system and proves the VisionScan technique is a non-destructive solution to assure package integrity. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Popular Plastics & Packaging is the property of Colour Publications Pvt, Ltd. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=141535478
RecordInfo BibRecord:
  BibEntity:
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 6
        StartPage: 32
    Subjects:
      – SubjectFull: Leak detection
        Type: general
      – SubjectFull: Methods engineering
        Type: general
      – SubjectFull: Test systems
        Type: general
      – SubjectFull: Imaging systems
        Type: general
    Titles:
      – TitleFull: Stability testing blister packs inspected with Sepha's VisionScan test method.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Dixon, D.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 01
              Text: Jan2020
              Type: published
              Y: 2020
          Identifiers:
            – Type: issn-print
              Value: 09710078
          Numbering:
            – Type: volume
              Value: 65
            – Type: issue
              Value: 1
          Titles:
            – TitleFull: Popular Plastics & Packaging
              Type: main
ResultId 1