Nanodosimetric quantities and RBE of a clinically relevant carbon‐ion beam.
Saved in:
| Title: | Nanodosimetric quantities and RBE of a clinically relevant carbon‐ion beam. |
|---|---|
| Authors: | Dai, Tianyuan1,2,3,4 (AUTHOR), Li, Qiang1,2,3,4 (AUTHOR) liqiang@impcas.ac.cn, Liu, Xinguo1,2,3,4 (AUTHOR), Dai, Zhongying1,2,3,4 (AUTHOR), He, Pengbo1,2,3,4 (AUTHOR), Ma, Yuanyuan1,2,3,4 (AUTHOR), Shen, Guosheng1,2,3,4 (AUTHOR), Chen, Weiqiang1,2,3,4 (AUTHOR), Zhang, Hui1,2,3,4 (AUTHOR), Meng, Qianqian1,2,3,4 (AUTHOR), Zhang, Xiaofang1,2,3,4 (AUTHOR) |
| Source: | Medical Physics. Feb2020, Vol. 47 Issue 2, p772-780. 9p. |
| Subjects: | Ion beams, Conditional probability, Electron impact ionization, Monte Carlo method |
| Abstract: | Purpose: Although carbon‐ion therapy is becoming increasingly attractive to the treatment of tumors, details about the ionization pattern formed by therapeutic carbon‐ion beam in tissue have not been fully investigated. In this work, systematic calculations for the nanodosimetric quantities and relative biological effectiveness (RBE) of a clinically relevant carbon‐ion beam were studied for the first time. Methods: The method combining both track structure and condensed history Monte Carlo (MC) simulations was adopted to calculate the nanodosimetric quantities. Fragments and energy spectra at different positions of the radiation field of a clinically relevant carbon‐ion pencil beam were generated by means of MC simulations in water. Nanodosimetric quantities such as mean ionization cluster size (M1), the first moment of conditional cluster size (M1C2), cumulative probability (F2), and conditional cumulative probability (F3C2) at these positions were then acquired based on the spectra and the pre‐calculated nanodosimetric database created by track structure MC simulations. What's more, a novel approach to calculate RBE based on the said nanodosimetric quantities was introduced. The RBE calculations were then conducted for the carbon‐ion beam at different water‐equivalent depths. Results: Lateral distributions at various water‐equivalent depths of both the nanodosimetric quantities and RBE values were obtained. The values of M1, M1C2, F2, and F3C2 were 1.49, 2.67, 0.30, and 0.38 at the plateau at the beam central axis and maximized at 2.79, 5.69, 0.47, and 0.68 at the depths around the Bragg peak, respectively. At a given depth, M1 and F2 decreased laterally with increasing the distance to the beam central axis while M1C2 and F3C2 remained nearly unchanged at first and then decreased except for M1C2 at the rising edge of the Bragg peak. The calculated RBE values were 1.07 at the plateau and 3.13 around the Bragg peak. Good agreement between the calculated RBE values and experimental data was obtained. Conclusions: Different nanodosimetric quantities feature the track structure of therapeutic carbon‐ion beam in different manners. Detailed ionization patterns generated by carbon‐ion beam could be characterized by nanodosimetric quantities. Moreover the combined method adopted in this work to calculate nanodosimetric quantities is not only valid but also convenient. Nanodosimetric quantities are significantly helpful for the RBE calculations in carbon‐ion therapy. [ABSTRACT FROM AUTHOR] |
| Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
|
Full text is not displayed to guests.
Login for full access.
|
|
| FullText | Links: – Type: pdflink Text: Availability: 1 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 141676974 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Nanodosimetric quantities and RBE of a clinically relevant carbon‐ion beam. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Dai%2C+Tianyuan%22">Dai, Tianyuan</searchLink><relatesTo>1,2,3,4</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Li%2C+Qiang%22">Li, Qiang</searchLink><relatesTo>1,2,3,4</relatesTo> (AUTHOR)<i> liqiang@impcas.ac.cn</i><br /><searchLink fieldCode="AR" term="%22Liu%2C+Xinguo%22">Liu, Xinguo</searchLink><relatesTo>1,2,3,4</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Dai%2C+Zhongying%22">Dai, Zhongying</searchLink><relatesTo>1,2,3,4</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22He%2C+Pengbo%22">He, Pengbo</searchLink><relatesTo>1,2,3,4</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Ma%2C+Yuanyuan%22">Ma, Yuanyuan</searchLink><relatesTo>1,2,3,4</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Shen%2C+Guosheng%22">Shen, Guosheng</searchLink><relatesTo>1,2,3,4</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Chen%2C+Weiqiang%22">Chen, Weiqiang</searchLink><relatesTo>1,2,3,4</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Zhang%2C+Hui%22">Zhang, Hui</searchLink><relatesTo>1,2,3,4</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Meng%2C+Qianqian%22">Meng, Qianqian</searchLink><relatesTo>1,2,3,4</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Zhang%2C+Xiaofang%22">Zhang, Xiaofang</searchLink><relatesTo>1,2,3,4</relatesTo> (AUTHOR) – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Medical+Physics%22">Medical Physics</searchLink>. Feb2020, Vol. 47 Issue 2, p772-780. 9p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Ion+beams%22">Ion beams</searchLink><br /><searchLink fieldCode="DE" term="%22Conditional+probability%22">Conditional probability</searchLink><br /><searchLink fieldCode="DE" term="%22Electron+impact+ionization%22">Electron impact ionization</searchLink><br /><searchLink fieldCode="DE" term="%22Monte+Carlo+method%22">Monte Carlo method</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: Purpose: Although carbon‐ion therapy is becoming increasingly attractive to the treatment of tumors, details about the ionization pattern formed by therapeutic carbon‐ion beam in tissue have not been fully investigated. In this work, systematic calculations for the nanodosimetric quantities and relative biological effectiveness (RBE) of a clinically relevant carbon‐ion beam were studied for the first time. Methods: The method combining both track structure and condensed history Monte Carlo (MC) simulations was adopted to calculate the nanodosimetric quantities. Fragments and energy spectra at different positions of the radiation field of a clinically relevant carbon‐ion pencil beam were generated by means of MC simulations in water. Nanodosimetric quantities such as mean ionization cluster size (M1), the first moment of conditional cluster size (M1C2), cumulative probability (F2), and conditional cumulative probability (F3C2) at these positions were then acquired based on the spectra and the pre‐calculated nanodosimetric database created by track structure MC simulations. What's more, a novel approach to calculate RBE based on the said nanodosimetric quantities was introduced. The RBE calculations were then conducted for the carbon‐ion beam at different water‐equivalent depths. Results: Lateral distributions at various water‐equivalent depths of both the nanodosimetric quantities and RBE values were obtained. The values of M1, M1C2, F2, and F3C2 were 1.49, 2.67, 0.30, and 0.38 at the plateau at the beam central axis and maximized at 2.79, 5.69, 0.47, and 0.68 at the depths around the Bragg peak, respectively. At a given depth, M1 and F2 decreased laterally with increasing the distance to the beam central axis while M1C2 and F3C2 remained nearly unchanged at first and then decreased except for M1C2 at the rising edge of the Bragg peak. The calculated RBE values were 1.07 at the plateau and 3.13 around the Bragg peak. Good agreement between the calculated RBE values and experimental data was obtained. Conclusions: Different nanodosimetric quantities feature the track structure of therapeutic carbon‐ion beam in different manners. Detailed ionization patterns generated by carbon‐ion beam could be characterized by nanodosimetric quantities. Moreover the combined method adopted in this work to calculate nanodosimetric quantities is not only valid but also convenient. Nanodosimetric quantities are significantly helpful for the RBE calculations in carbon‐ion therapy. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=141676974 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1002/mp.13914 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 9 StartPage: 772 Subjects: – SubjectFull: Ion beams Type: general – SubjectFull: Conditional probability Type: general – SubjectFull: Electron impact ionization Type: general – SubjectFull: Monte Carlo method Type: general Titles: – TitleFull: Nanodosimetric quantities and RBE of a clinically relevant carbon‐ion beam. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Dai, Tianyuan – PersonEntity: Name: NameFull: Li, Qiang – PersonEntity: Name: NameFull: Liu, Xinguo – PersonEntity: Name: NameFull: Dai, Zhongying – PersonEntity: Name: NameFull: He, Pengbo – PersonEntity: Name: NameFull: Ma, Yuanyuan – PersonEntity: Name: NameFull: Shen, Guosheng – PersonEntity: Name: NameFull: Chen, Weiqiang – PersonEntity: Name: NameFull: Zhang, Hui – PersonEntity: Name: NameFull: Meng, Qianqian – PersonEntity: Name: NameFull: Zhang, Xiaofang IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 02 Text: Feb2020 Type: published Y: 2020 Identifiers: – Type: issn-print Value: 00942405 Numbering: – Type: volume Value: 47 – Type: issue Value: 2 Titles: – TitleFull: Medical Physics Type: main |
| ResultId | 1 |