Subcapsular Injection of Ultrasonic Contrast Agent Distinguishes between Benign and Malignant Lymph Node Lesions Exhibiting Homogeneous Enhancement in Intravenous Contrast-Enhanced Ultrasound Images.

Saved in:
Bibliographic Details
Title: Subcapsular Injection of Ultrasonic Contrast Agent Distinguishes between Benign and Malignant Lymph Node Lesions Exhibiting Homogeneous Enhancement in Intravenous Contrast-Enhanced Ultrasound Images.
Authors: Liu, Shi-rong1 (AUTHOR), Liu, Chang1 (AUTHOR), Jing, Hong-mei2 (AUTHOR), Miao, Li-Ying1 (AUTHOR), Cui, Li-gang1 (AUTHOR), Qian, Lin-Xue3 (AUTHOR), Tan, Shi1 (AUTHOR) tenshi@126.com
Source: Ultrasound in Medicine & Biology. Mar2020, Vol. 46 Issue 3, p582-588. 7p.
Subjects: Contrast-enhanced ultrasound, Ultrasonic imaging, Lymph nodes, Core needle biopsy, Injections
Abstract: We aimed to evaluate whether subcapsular injection of ultrasonic contrast agent (UCA) can distinguish between benign and malignant lymph node (LN) lesions exhibiting homogeneous enhancement in intravenous contrast-enhanced ultrasound (CEUS) images. From November 2012 to July 2015, 32 patients with superficial lymphadenopathy exhibiting homogeneous enhancement after intravenous CEUS were enrolled. A small amount of UCA was injected into LNs using a subcapsular approach, and perfusion characteristics were recorded. Using the pathology identified via core needle biopsy as the gold standard, we calculated the sensitivity, specificity and accuracy of the technique in terms of distinguishing between benign and malignant LN lesions. Pathology revealed 23 cases of true benign and 9 cases of true malignant LN lesions; the former included 2 cases of tuberculosis and 21 cases of reactive hyperplasia, and the latter included 7 lymphomas and 2 metastases. Subcapsular CEUS diagnosed 24 benign and 8 malignant LN lesions. Most lymphomas (6 of 7, 85.7%) exhibited heterogeneous perfusion, with lymphatic tract distortion in the absence of interruption. Reactive hyperplasia LNs manifested as diffuse homogeneous or brush-like perfusion from the subcapsular region to the center, without lymphatic tract distortion. Metastatic LNs had lymphatic tract interruptions. The sensitivity, specificity, consistency and positive and negative predictive values were 77.8%, 95.6%, 90.6%, 87.5% and 91.7%, respectively. For LNs exhibiting uniform enhancement in intravenous CEUS imaging, subcapsular CEUS may help to distinguish between benign and malignant lesions. In particular, lymphatic distortion without interruption may specifically indicate a lymphoma. [ABSTRACT FROM AUTHOR]
Copyright of Ultrasound in Medicine & Biology is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 141942376
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Subcapsular Injection of Ultrasonic Contrast Agent Distinguishes between Benign and Malignant Lymph Node Lesions Exhibiting Homogeneous Enhancement in Intravenous Contrast-Enhanced Ultrasound Images.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Liu%2C+Shi-rong%22">Liu, Shi-rong</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Liu%2C+Chang%22">Liu, Chang</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Jing%2C+Hong-mei%22">Jing, Hong-mei</searchLink><relatesTo>2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Miao%2C+Li-Ying%22">Miao, Li-Ying</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Cui%2C+Li-gang%22">Cui, Li-gang</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Qian%2C+Lin-Xue%22">Qian, Lin-Xue</searchLink><relatesTo>3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Tan%2C+Shi%22">Tan, Shi</searchLink><relatesTo>1</relatesTo> (AUTHOR)<i> tenshi@126.com</i>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Ultrasound+in+Medicine+%26+Biology%22">Ultrasound in Medicine & Biology</searchLink>. Mar2020, Vol. 46 Issue 3, p582-588. 7p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Contrast-enhanced+ultrasound%22">Contrast-enhanced ultrasound</searchLink><br /><searchLink fieldCode="DE" term="%22Ultrasonic+imaging%22">Ultrasonic imaging</searchLink><br /><searchLink fieldCode="DE" term="%22Lymph+nodes%22">Lymph nodes</searchLink><br /><searchLink fieldCode="DE" term="%22Core+needle+biopsy%22">Core needle biopsy</searchLink><br /><searchLink fieldCode="DE" term="%22Injections%22">Injections</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: We aimed to evaluate whether subcapsular injection of ultrasonic contrast agent (UCA) can distinguish between benign and malignant lymph node (LN) lesions exhibiting homogeneous enhancement in intravenous contrast-enhanced ultrasound (CEUS) images. From November 2012 to July 2015, 32 patients with superficial lymphadenopathy exhibiting homogeneous enhancement after intravenous CEUS were enrolled. A small amount of UCA was injected into LNs using a subcapsular approach, and perfusion characteristics were recorded. Using the pathology identified via core needle biopsy as the gold standard, we calculated the sensitivity, specificity and accuracy of the technique in terms of distinguishing between benign and malignant LN lesions. Pathology revealed 23 cases of true benign and 9 cases of true malignant LN lesions; the former included 2 cases of tuberculosis and 21 cases of reactive hyperplasia, and the latter included 7 lymphomas and 2 metastases. Subcapsular CEUS diagnosed 24 benign and 8 malignant LN lesions. Most lymphomas (6 of 7, 85.7%) exhibited heterogeneous perfusion, with lymphatic tract distortion in the absence of interruption. Reactive hyperplasia LNs manifested as diffuse homogeneous or brush-like perfusion from the subcapsular region to the center, without lymphatic tract distortion. Metastatic LNs had lymphatic tract interruptions. The sensitivity, specificity, consistency and positive and negative predictive values were 77.8%, 95.6%, 90.6%, 87.5% and 91.7%, respectively. For LNs exhibiting uniform enhancement in intravenous CEUS imaging, subcapsular CEUS may help to distinguish between benign and malignant lesions. In particular, lymphatic distortion without interruption may specifically indicate a lymphoma. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Ultrasound in Medicine & Biology is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=141942376
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1016/j.ultrasmedbio.2019.12.004
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 7
        StartPage: 582
    Subjects:
      – SubjectFull: Contrast-enhanced ultrasound
        Type: general
      – SubjectFull: Ultrasonic imaging
        Type: general
      – SubjectFull: Lymph nodes
        Type: general
      – SubjectFull: Core needle biopsy
        Type: general
      – SubjectFull: Injections
        Type: general
    Titles:
      – TitleFull: Subcapsular Injection of Ultrasonic Contrast Agent Distinguishes between Benign and Malignant Lymph Node Lesions Exhibiting Homogeneous Enhancement in Intravenous Contrast-Enhanced Ultrasound Images.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Liu, Shi-rong
      – PersonEntity:
          Name:
            NameFull: Liu, Chang
      – PersonEntity:
          Name:
            NameFull: Jing, Hong-mei
      – PersonEntity:
          Name:
            NameFull: Miao, Li-Ying
      – PersonEntity:
          Name:
            NameFull: Cui, Li-gang
      – PersonEntity:
          Name:
            NameFull: Qian, Lin-Xue
      – PersonEntity:
          Name:
            NameFull: Tan, Shi
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 03
              Text: Mar2020
              Type: published
              Y: 2020
          Identifiers:
            – Type: issn-print
              Value: 03015629
          Numbering:
            – Type: volume
              Value: 46
            – Type: issue
              Value: 3
          Titles:
            – TitleFull: Ultrasound in Medicine & Biology
              Type: main
ResultId 1