The effect of high-velocity dust particle impacts on microchannel plate (MCP) detectors.

Saved in:
Bibliographic Details
Title: The effect of high-velocity dust particle impacts on microchannel plate (MCP) detectors.
Authors: Gemer, A.J.1,2 (AUTHOR) gemer@colorado.edu, Sternovsky, Z.1,2 (AUTHOR), James, D.1 (AUTHOR), Horanyi, M.1,3 (AUTHOR)
Source: Planetary & Space Science. Apr2020, Vol. 183, pN.PAG-N.PAG. 1p.
Subjects: Microchannel plates, Dust, Detectors, Cosmic dust, Scanning electron microscopes, Impact craters
Abstract: The detection efficiency and durability of a microchannel plate (MCP) detector to direct impacts of high-velocity dust particles is investigated experimentally. A new type of in situ time-of-flight cosmic dust analyzer instrument has been developed, where the ion detector is exposed to occasional impacts of cosmic dust particles. The dust accelerator facility operated at the University of Colorado is used to directly measure the effect of dust impacts on a commercial, off-the-shelf microchannel plate (MCP) detector. The MCP is exposed to approx. 480 dust particle impacts from wide size and velocity ranges of 0.05–1.6 μm radii and 2–35 km/s, respectively. The dust impact events are registered with 96% efficiency. Of these, 57% of the output signals are single charge pulses, and 43% are more complex signals that suggest ion feedback mechanisms within the detector. For all dust detection events, the output charge pulse is significantly larger than those from the detection of single ions or photons. The gain of the MCP detector shows no apparent degradation after the bombardment. In the investigated size/velocity range, the dust particles do not pose a risk of damaging the MCP. Scanning electron microscope images show that the impact generated craters are small, on the order of the size of the impacting particles. The performed measurements and the extrapolation of the results to the worst case expected to occur for the duration of a spaceflight mission indicate that MCP detectors require protection from dust impacts in order to reduce the risk of detector damage for these types of dust analyzer instruments, and a mechanism for providing protection is described. • Microchannel Plate Detectors register direct dust impacts with 96% efficiency. • Dust impact signals distinguishable from single ion detections. • Detector gain is not degraded after 480, 0.05–1.6 μm, 2–35 km/s dust impacts. • Risk of detector damage can be mitigated using discrete BeCu dynodes as shields. [ABSTRACT FROM AUTHOR]
Copyright of Planetary & Space Science is the property of Pergamon Press - An Imprint of Elsevier Science and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Description
Abstract:The detection efficiency and durability of a microchannel plate (MCP) detector to direct impacts of high-velocity dust particles is investigated experimentally. A new type of in situ time-of-flight cosmic dust analyzer instrument has been developed, where the ion detector is exposed to occasional impacts of cosmic dust particles. The dust accelerator facility operated at the University of Colorado is used to directly measure the effect of dust impacts on a commercial, off-the-shelf microchannel plate (MCP) detector. The MCP is exposed to approx. 480 dust particle impacts from wide size and velocity ranges of 0.05–1.6 μm radii and 2–35 km/s, respectively. The dust impact events are registered with 96% efficiency. Of these, 57% of the output signals are single charge pulses, and 43% are more complex signals that suggest ion feedback mechanisms within the detector. For all dust detection events, the output charge pulse is significantly larger than those from the detection of single ions or photons. The gain of the MCP detector shows no apparent degradation after the bombardment. In the investigated size/velocity range, the dust particles do not pose a risk of damaging the MCP. Scanning electron microscope images show that the impact generated craters are small, on the order of the size of the impacting particles. The performed measurements and the extrapolation of the results to the worst case expected to occur for the duration of a spaceflight mission indicate that MCP detectors require protection from dust impacts in order to reduce the risk of detector damage for these types of dust analyzer instruments, and a mechanism for providing protection is described. • Microchannel Plate Detectors register direct dust impacts with 96% efficiency. • Dust impact signals distinguishable from single ion detections. • Detector gain is not degraded after 480, 0.05–1.6 μm, 2–35 km/s dust impacts. • Risk of detector damage can be mitigated using discrete BeCu dynodes as shields. [ABSTRACT FROM AUTHOR]