The Rtx-Dioxin2 and Rxi-17SilMS as Alternative Gas Chromatographic Confirmation Columns for Dioxin Analysis.

Saved in:
Bibliographic Details
Title: The Rtx-Dioxin2 and Rxi-17SilMS as Alternative Gas Chromatographic Confirmation Columns for Dioxin Analysis.
Authors: Stultz, Conner1 (AUTHOR), Dorman, Frank1,2 (AUTHOR) fld3@psu.edu
Source: Journal of Chromatography A. Aug2020, Vol. 1625, pN.PAG-N.PAG. 1p.
Subjects: Polychlorinated dibenzodioxins, Dioxins, Requirements engineering, Furans
Abstract: • Rtx-Dioxin2 and Rxi-17SilMS can be used for dioxin analysis as confirmation columns • Common dioxin congener coelutions are discussed on four different GC columns • Rtx-Dioxin2 can be used with Rxi-17SilMS for unbiased hexachlorinated dibenzo- p -dioxin identification • Rtx-Dioxin2 can be used with Rxi-17SilMS or Rtx-2330 for unbiased pentachlorinated dibenzofuran identification Polychlorinated dibenzo- p -dioxins and furans are environmentally persistent and highly toxic compounds. 136 chlorinated dioxins and furan congeners contain at least four chlorine atoms and pose a complex separation challenge in environmental and biological matrixes. The complexity arises from the dioxin and furan molecules with substitutions at positions 2, 3, 7, and 8, which are toxicologically relevant but are not easily separated from the other non-/less toxic congeners. Many regulatory methods require the use of two columns with different polarities or selectivity for dioxin analysis. The most common confirmation column pair is a (5% phenyl)-methylpolysiloxane and a (biscyanopropyl-/ cyanopropylphenyl)-methylpolysiloxane. These phases are required in USEPA-1613 for 2,3,7,8-tetrachlorodibenzo- p -dioxin and 2,3,7,8-tetrachlorodibenzofuran specificity. However, other column phases, such as the Rxi-17SilMS and the Rtx-Dioxin2, offer alternatives to the traditional column pairing and provide a similar or better separation of 2,3,7,8-substituted congeners. This study compares four columns for dioxin analysis: the Rtx-Dioxin2, Rxi-17SilMS, Rxi-5SilMS, and Rtx-2330. All columns used in this study are capable of meeting the requirements for dioxin analysis required by USEPA-1613. However, the Rtx-Dioxin2 demonstrated improved selectivity for a wider range of dioxin compounds than the Rxi-5SilMS. The Rtx-Dioxin2 is capable of resolving 2,3,7,8-tetrachlorodibenzo- p -dioxin and 2,3,7,8-tetrachlorodibenzofuran from common interferants better than the Rxi-5SilMS and can be used as a confirmation column with either the Rtx-2330 or Rxi-17SilMS. [ABSTRACT FROM AUTHOR]
Copyright of Journal of Chromatography A is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 144690150
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: The Rtx-Dioxin2 and Rxi-17SilMS as Alternative Gas Chromatographic Confirmation Columns for Dioxin Analysis.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Stultz%2C+Conner%22">Stultz, Conner</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Dorman%2C+Frank%22">Dorman, Frank</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<i> fld3@psu.edu</i>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Journal+of+Chromatography+A%22">Journal of Chromatography A</searchLink>. Aug2020, Vol. 1625, pN.PAG-N.PAG. 1p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Polychlorinated+dibenzodioxins%22">Polychlorinated dibenzodioxins</searchLink><br /><searchLink fieldCode="DE" term="%22Dioxins%22">Dioxins</searchLink><br /><searchLink fieldCode="DE" term="%22Requirements+engineering%22">Requirements engineering</searchLink><br /><searchLink fieldCode="DE" term="%22Furans%22">Furans</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: • Rtx-Dioxin2 and Rxi-17SilMS can be used for dioxin analysis as confirmation columns • Common dioxin congener coelutions are discussed on four different GC columns • Rtx-Dioxin2 can be used with Rxi-17SilMS for unbiased hexachlorinated dibenzo- p -dioxin identification • Rtx-Dioxin2 can be used with Rxi-17SilMS or Rtx-2330 for unbiased pentachlorinated dibenzofuran identification Polychlorinated dibenzo- p -dioxins and furans are environmentally persistent and highly toxic compounds. 136 chlorinated dioxins and furan congeners contain at least four chlorine atoms and pose a complex separation challenge in environmental and biological matrixes. The complexity arises from the dioxin and furan molecules with substitutions at positions 2, 3, 7, and 8, which are toxicologically relevant but are not easily separated from the other non-/less toxic congeners. Many regulatory methods require the use of two columns with different polarities or selectivity for dioxin analysis. The most common confirmation column pair is a (5% phenyl)-methylpolysiloxane and a (biscyanopropyl-/ cyanopropylphenyl)-methylpolysiloxane. These phases are required in USEPA-1613 for 2,3,7,8-tetrachlorodibenzo- p -dioxin and 2,3,7,8-tetrachlorodibenzofuran specificity. However, other column phases, such as the Rxi-17SilMS and the Rtx-Dioxin2, offer alternatives to the traditional column pairing and provide a similar or better separation of 2,3,7,8-substituted congeners. This study compares four columns for dioxin analysis: the Rtx-Dioxin2, Rxi-17SilMS, Rxi-5SilMS, and Rtx-2330. All columns used in this study are capable of meeting the requirements for dioxin analysis required by USEPA-1613. However, the Rtx-Dioxin2 demonstrated improved selectivity for a wider range of dioxin compounds than the Rxi-5SilMS. The Rtx-Dioxin2 is capable of resolving 2,3,7,8-tetrachlorodibenzo- p -dioxin and 2,3,7,8-tetrachlorodibenzofuran from common interferants better than the Rxi-5SilMS and can be used as a confirmation column with either the Rtx-2330 or Rxi-17SilMS. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Journal of Chromatography A is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=144690150
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1016/j.chroma.2020.461263
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 1
        StartPage: N.PAG
    Subjects:
      – SubjectFull: Polychlorinated dibenzodioxins
        Type: general
      – SubjectFull: Dioxins
        Type: general
      – SubjectFull: Requirements engineering
        Type: general
      – SubjectFull: Furans
        Type: general
    Titles:
      – TitleFull: The Rtx-Dioxin2 and Rxi-17SilMS as Alternative Gas Chromatographic Confirmation Columns for Dioxin Analysis.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Stultz, Conner
      – PersonEntity:
          Name:
            NameFull: Dorman, Frank
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 16
              M: 08
              Text: Aug2020
              Type: published
              Y: 2020
          Identifiers:
            – Type: issn-print
              Value: 00219673
          Numbering:
            – Type: volume
              Value: 1625
          Titles:
            – TitleFull: Journal of Chromatography A
              Type: main
ResultId 1