Integrated model for methane emission and dispersion assessment from landfills: A case study of Ho Chi Minh City, Vietnam.

Saved in:
Bibliographic Details
Title: Integrated model for methane emission and dispersion assessment from landfills: A case study of Ho Chi Minh City, Vietnam.
Authors: Bui, Long Ta1 (AUTHOR) longbt62@hcmut.edu.vn, Nguyen, Phong Hoang1 (AUTHOR)
Source: Science of the Total Environment. Oct2020, Vol. 738, pN.PAG-N.PAG. 1p.
Abstract: Methane is considered to be one of the main causes of global warming. Quantifying methane emissions from landfills is the subject of many studies, especially emphasizing the role of two parameters: methane generation potential capacity (L 0), methane generation rate (k). In this study, we propose a system of integrated environmental information and mathematical model named EnLandFill (EN vironmental information – model integrated system for air emission and dispersion estimation from LandFill) that allows calculation L 0 from database and experimentally to determine optimal k. To perform experimental calculations, meteorological data were extracted from the WRF model and verified with real measurements. The novelty of this study lies in the inferred database system, the math model bank, especially the dispersion model, taking note account the complex topography, meteorological factors that change by the hour. EnLandFill was applied to Phuoc Hiep Landfill (PHLF) in Ho Chi Minh City as a case study, the results have identified the amount of methane released that is equal to 44,094,697.88 m3/year in 2019, but EnLandFill is designed to be general, applicable to other landfill entities. Unlabelled Image • Proposed a system of integrated environmental information and mathematical model named EnLandFill that allows calculate the potential methane generation capacity and experimentally to determine optimal methane generation rate. • The proposed system allows the assessment of the scope and extent of impacts caused by the dispersion of toxic substances from landfills. • Using the proposed system it is allowed calculate the amount of methane emitted from Phuoc Hiep landfill (PHLF) - the largest waste treatment complexes in Hochiminh city for 2019 is 44,094,697.88 m3/year. [ABSTRACT FROM AUTHOR]
Copyright of Science of the Total Environment is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 145055973
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Integrated model for methane emission and dispersion assessment from landfills: A case study of Ho Chi Minh City, Vietnam.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Bui%2C+Long+Ta%22">Bui, Long Ta</searchLink><relatesTo>1</relatesTo> (AUTHOR)<i> longbt62@hcmut.edu.vn</i><br /><searchLink fieldCode="AR" term="%22Nguyen%2C+Phong+Hoang%22">Nguyen, Phong Hoang</searchLink><relatesTo>1</relatesTo> (AUTHOR)
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Science+of+the+Total+Environment%22">Science of the Total Environment</searchLink>. Oct2020, Vol. 738, pN.PAG-N.PAG. 1p.
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Methane is considered to be one of the main causes of global warming. Quantifying methane emissions from landfills is the subject of many studies, especially emphasizing the role of two parameters: methane generation potential capacity (L 0), methane generation rate (k). In this study, we propose a system of integrated environmental information and mathematical model named EnLandFill (EN vironmental information – model integrated system for air emission and dispersion estimation from LandFill) that allows calculation L 0 from database and experimentally to determine optimal k. To perform experimental calculations, meteorological data were extracted from the WRF model and verified with real measurements. The novelty of this study lies in the inferred database system, the math model bank, especially the dispersion model, taking note account the complex topography, meteorological factors that change by the hour. EnLandFill was applied to Phuoc Hiep Landfill (PHLF) in Ho Chi Minh City as a case study, the results have identified the amount of methane released that is equal to 44,094,697.88 m3/year in 2019, but EnLandFill is designed to be general, applicable to other landfill entities. Unlabelled Image • Proposed a system of integrated environmental information and mathematical model named EnLandFill that allows calculate the potential methane generation capacity and experimentally to determine optimal methane generation rate. • The proposed system allows the assessment of the scope and extent of impacts caused by the dispersion of toxic substances from landfills. • Using the proposed system it is allowed calculate the amount of methane emitted from Phuoc Hiep landfill (PHLF) - the largest waste treatment complexes in Hochiminh city for 2019 is 44,094,697.88 m3/year. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Science of the Total Environment is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=145055973
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1016/j.scitotenv.2020.139865
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 1
        StartPage: N.PAG
    Titles:
      – TitleFull: Integrated model for methane emission and dispersion assessment from landfills: A case study of Ho Chi Minh City, Vietnam.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Bui, Long Ta
      – PersonEntity:
          Name:
            NameFull: Nguyen, Phong Hoang
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 10
              M: 10
              Text: Oct2020
              Type: published
              Y: 2020
          Identifiers:
            – Type: issn-print
              Value: 00489697
          Numbering:
            – Type: volume
              Value: 738
          Titles:
            – TitleFull: Science of the Total Environment
              Type: main
ResultId 1