Clinical outcomes of micropulse transscleral cyclophotocoagulation in refractory glaucoma—18 months follow-up.
Saved in:
| Title: | Clinical outcomes of micropulse transscleral cyclophotocoagulation in refractory glaucoma—18 months follow-up. |
|---|---|
| Authors: | Preda, Maria Alexandra1, Karancsi, Olimpiu L.2, Munteanu, Mihnea1 mihneam1@gmail.com, Stanca, Horia T.3 |
| Source: | Lasers in Medical Science. Sep2020, Vol. 35 Issue 7, p1487-1491. 5p. |
| Subjects: | Glaucoma treatment, Light coagulation, Intraocular pressure, Semiconductor lasers, Glaucoma, Surgical complications |
| Abstract: | The aim of this study is to evaluate the clinical outcomes of micropulse transscleral cyclophotocoagulation (mTSCPC) in cases of refractory glaucoma. Patients with refractory glaucoma were selected to undergo mTSCPC, using the MP3 handpiece from Iridex Laser Systems. Follow-up examinations occurred on a regular basis for 18 months after the procedure. One hundred eyes of 97 patients were treated. Mean pre-laser intraocular pressure (IOP) was 39.14 ± 13.84 mmHg. This was reduced significantly to 22.77.8 ± 10.48 mmHg (41.82% reduction; p < 0.001) at week 1. At months 1, 3, 6, 12, and 18 the IOP mean was 23.81 ± 9.44, 24.27 ± 9.17, 23.09 ± 8.47, 22.76 ± 8.14, and 22.77 ± 8.13 mmHg. The success rate at 18 months was the highest 90.91% for the group with IOP below 26 mmHg and the lowest 70.00% for the IOP group 26–30 mmHg. The mean number of anti-glaucoma drops decreased from 2.63 ± 0.87 to 1.78 ± 0.95. The number of treatments performed was 1.26. The pain felt during the procedure was reported as being moderate. No major postoperative complications were noted. Micropulse transscleral cyclophotocoagulation is a non-invasive, repeatable laser procedure that offers both good and stable results in lowering IOP and decreases the use of antiglaucoma medications for up to 18 months. [ABSTRACT FROM AUTHOR] |
| Copyright of Lasers in Medical Science is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
|
Full text is not displayed to guests.
Login for full access.
|
|
| FullText | Links: – Type: pdflink Text: Availability: 1 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 145079186 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Clinical outcomes of micropulse transscleral cyclophotocoagulation in refractory glaucoma—18 months follow-up. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Preda%2C+Maria+Alexandra%22">Preda, Maria Alexandra</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Karancsi%2C+Olimpiu+L%2E%22">Karancsi, Olimpiu L.</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Munteanu%2C+Mihnea%22">Munteanu, Mihnea</searchLink><relatesTo>1</relatesTo><i> mihneam1@gmail.com</i><br /><searchLink fieldCode="AR" term="%22Stanca%2C+Horia+T%2E%22">Stanca, Horia T.</searchLink><relatesTo>3</relatesTo> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Lasers+in+Medical+Science%22">Lasers in Medical Science</searchLink>. Sep2020, Vol. 35 Issue 7, p1487-1491. 5p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Glaucoma+treatment%22">Glaucoma treatment</searchLink><br /><searchLink fieldCode="DE" term="%22Light+coagulation%22">Light coagulation</searchLink><br /><searchLink fieldCode="DE" term="%22Intraocular+pressure%22">Intraocular pressure</searchLink><br /><searchLink fieldCode="DE" term="%22Semiconductor+lasers%22">Semiconductor lasers</searchLink><br /><searchLink fieldCode="DE" term="%22Glaucoma%22">Glaucoma</searchLink><br /><searchLink fieldCode="DE" term="%22Surgical+complications%22">Surgical complications</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: The aim of this study is to evaluate the clinical outcomes of micropulse transscleral cyclophotocoagulation (mTSCPC) in cases of refractory glaucoma. Patients with refractory glaucoma were selected to undergo mTSCPC, using the MP3 handpiece from Iridex Laser Systems. Follow-up examinations occurred on a regular basis for 18 months after the procedure. One hundred eyes of 97 patients were treated. Mean pre-laser intraocular pressure (IOP) was 39.14 ± 13.84 mmHg. This was reduced significantly to 22.77.8 ± 10.48 mmHg (41.82% reduction; p < 0.001) at week 1. At months 1, 3, 6, 12, and 18 the IOP mean was 23.81 ± 9.44, 24.27 ± 9.17, 23.09 ± 8.47, 22.76 ± 8.14, and 22.77 ± 8.13 mmHg. The success rate at 18 months was the highest 90.91% for the group with IOP below 26 mmHg and the lowest 70.00% for the IOP group 26–30 mmHg. The mean number of anti-glaucoma drops decreased from 2.63 ± 0.87 to 1.78 ± 0.95. The number of treatments performed was 1.26. The pain felt during the procedure was reported as being moderate. No major postoperative complications were noted. Micropulse transscleral cyclophotocoagulation is a non-invasive, repeatable laser procedure that offers both good and stable results in lowering IOP and decreases the use of antiglaucoma medications for up to 18 months. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Lasers in Medical Science is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=145079186 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1007/s10103-019-02934-x Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 5 StartPage: 1487 Subjects: – SubjectFull: Glaucoma treatment Type: general – SubjectFull: Light coagulation Type: general – SubjectFull: Intraocular pressure Type: general – SubjectFull: Semiconductor lasers Type: general – SubjectFull: Glaucoma Type: general – SubjectFull: Surgical complications Type: general Titles: – TitleFull: Clinical outcomes of micropulse transscleral cyclophotocoagulation in refractory glaucoma—18 months follow-up. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Preda, Maria Alexandra – PersonEntity: Name: NameFull: Karancsi, Olimpiu L. – PersonEntity: Name: NameFull: Munteanu, Mihnea – PersonEntity: Name: NameFull: Stanca, Horia T. IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 09 Text: Sep2020 Type: published Y: 2020 Identifiers: – Type: issn-print Value: 02688921 Numbering: – Type: volume Value: 35 – Type: issue Value: 7 Titles: – TitleFull: Lasers in Medical Science Type: main |
| ResultId | 1 |